PDT 3200 Product Reference Guide: Chapter 4 Programming Parameters

Pages 81 to 86 of 132, from PDT 3200 Product Reference Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-3240 and Symbol PDT-3200

Page 81

Chapter 4 Programming Parameters Introduction This chapter contains information about programmable settings for the PDT 3200. You can use the PDT 3200 Configuration Utility (see chapter 3) or the bar codes provided in chapter 5 to program your PDT 3200. Table provides the following information: • Code Parameter is the human name for the programming option. • I.D. # is the decoder name for the programming option. For example, if you wanted to set a Code 39 minimum label length, you would use I.D. #01. Programming I.D. numbers given in this chapter can be used with all programming methods. • Type tells what kind of setting to use for each code parameter. - On/Off is a toggle. 1 turns the parameter on, and 0 turns it off. - Value requires a two-character entry (e.g., 02 for two beeps after each good read). • Acceptable Input gives the settings or range of settings that you can use for each code parameter. • Defaults tells how the parameter is set when you select predefined default D0, D1, or D2. - Predefined Default 0 (D0) turns every on/off parameter off and sets all minimum and maximum lengths to the lowest values. - Predefined Default 1 (D1) turns every on/off parameter on, sets all minimum lengths to the lowest values, and sets all maximum lengths to the highest values. This default set is normally used only for troubleshooting. It gives you the best chance of reading an unknown bar code symbology and also identifies the symbology of each bar code you scan. - Predefined Default 2 (D2) is the default set that was installed in the PDT 3200 at the factory. This default set will work for most applications. If you have 4-1

Page 82

PDT 3200 Product Reference Guide changed any settings and want to reset the PDT 3200 to the original defaults, scan the D2 bar code on page 5-4. Table 4-1. Parameters, Settings, and Defaults Code Parameter Code 39

I.D. #

Defaults

Type

Acceptable Input

D0

D1

D2

Enter 1 for On and 0 for Off.

Enable

00

On/Off

On or Off

Off

On

On

Minimum length

01

Value

00–50

00

00

00

Maximum length

02

Value

01–50

01

50

20

Enable checksum

03

On/Off

On or Off

Off

Off

Off

Send checksum

04

On/Off

On or Off

Off

Off

Off

Full ASCII mode

05

On/Off

On or Off

Off

On

On

On/Off

On or Off

Off

On

On

Interleaved 2 of 5 Enter 1 for On and 0 for Off.

Enable

08

Minimum length

09

Value

02–50

02

02

06

Maximum length

0A

Value

02–50

02

50

10

Enable checksum

0B

On/Off

On or Off

Off

Off

Off

Send checksum

0C

On/Off

On or Off

Off

Off

Off

Use lengths 6 and 14 only (case code)

0D

On/Off

On or Off

Off

Off

Off

Matrix 2 of 5

Enter 1 for On and 0 for Off.

Enable

10

On/Off

On or Off

Off

On

Off

Minimum length

11

Value

01–50

01

01

06

Maximum length

12

Value

01–50

1

50

10

Enable checksum

13

On/Off

On or Off

Off

Off

Off

Send checksum

14

On/Off

On or Off

Off

Off

Off

Standard 2 of 5

Enter 1 for On and 0 for Off.

Enable

15

On/Off

On or Off

Off

On

Off

Minimum length

16

Value

01–50

01

01

06

Maximum length

17

Value

01–50

01

50

10

Enable checksum

18

On/Off

On or Off

Off

Off

Off

Send checksum

19

On/Off

On or Off

Off

Off

Off

Use 2-bar start/stop

1A

On/Off

On or Off

Off

Off

Off

4-2

Page 83

Chapter 4: Programming Parameters

Code Parameter Code 11

I.D. #

Defaults

Type

Acceptable Input

D0

D1

D2

Enter 1 for On and 0 for Off.

Enable

1B

On/Off

On or Off

Off

On

Off

Minimum length

1C

Value

01–50

01

01

04

Maximum length

1D

Value

01–50

01

50

10

Require 2 check digits

1E

On/Off

On or Off

Off

Off

Off

Send check digit(s)

1F

On/Off

On or Off

Off

On

Off

4-3

Page 84

PDT 3200 Product Reference Guide

Code Parameter Codabar/Ames

I.D. #

Defaults

Type

Acceptable Input

D0

D1

D2

Enter 1 for On and 0 for Off.

Enable

20

On/Off

On or Off

Off

On

On

Minimum length

21

Value

01–50

01

01

04

Maximum length

22

Value

01–50

01

50

20

Send start/stop

23

On/Off

On or Off

Off

On

Off

Codabar-to-CLSI conversion

24

On/Off

On or Off

Off

Off

Off

Wide intercharacter gaps allowed

25

On/Off

On or Off

Off

Off

On

On/Off

On or Off

Off

On

Off

MSI

Enter 1 for On and 0 for Off.

Enable

26

Minimum length

27

Value

01–14

01

01

04

Maximum length

28

Value

01–14

01

14

10

Require 2 check digits

29

On/Off

On or Off

Off

Off

Off

2nd check digit Mod 11

2A

On/Off

On or Off

Off

Off

Off

Send check digit(s)

2B

On/Off

On or Off

Off

On

Off

Universal Product Code-A (UPC-A)Enter 1 for On and 0 for Off.

Enable

30

On/Off

On or Off

Off

On

On

Send system digit

31

On/Off

On or Off

Off

On

On

Send check digit

32

On/Off

On or Off

Off

On

Off

Convert UPC-A to EAN-13

33

On/Off

On or Off

Off

On

Off

On or Off

Off

On

On

Universal Product Code-E (UPC-E)Enter 1 for On and 0 for Off.

Use system digit 0

34

On/Off

Use system digit 1

35

On/Off

On or Off

Off

On

On

Convert UPC-E to UPC-A

36

On/Off

On or Off

Off

On

Off

Send system digit

37

On/Off

On or Off

Off

On

Off

Send check digit

38

On/Off

On or Off

Off

On

Off

European Article Numbering (EAN) Japan Article Numbering (JAN)

Enter 1 for On and 0 for Off.

Enable EAN-8/JAN-8

39

On/Off

On or Off

Off

On

On

Enable EAN-13/JAN-13

3A

On/Off

On or Off

Off

On

On

Convert EAN-13 to ISBN

3B

On/Off

On or Off

Off

Off

Off

Send EAN/JAN checksum

3F

On/Off

On or Off

Off

Off

Off

4-4

Page 85

Chapter 4: Programming Parameters

Code Parameter

I.D. #

Defaults

Type

Acceptable Input

D0

D1

D2

UPC, EAN, JAN ExtensionsEnter 1 for On and 0 for Off.

Allow 2-digit extensions

3C

On/Off

On or Off

Off

On

On

Allow 5-digit extensions

3D

On/Off

On or Off

Off

On

On

Require extensions

3E

On/Off

On or Off

Off

Off

Off

Code 128

Enter 1 for On and 0 for Off.

Enable

40

On/Off

On or Off

Off

On

On

Minimum length

41

Value

01–50

01

01

02

Maximum length

42

Value

01–50

01

50

20

Enable UCC/EAN 128

43

On/Off

On or Off

Off

Off

Off

Labelcode 4/5

Enter 1 for On and 0 for Off.

Enable

52

On/Off

On or Off

Off

On

Off

Convert

53

On/Off

On or Off

Off

Off

Off

Other Controls

Enter 1 for On and 0 for Off.

Laser programming enable

B0

On/Off

On or Off

On

On

On

Autoterminator

B1

Value

Any single ASCII character (00 = Off)

(CR)

(CR)

(CR)

Auto-off timer

B2

Value

01–99 (in 4-sec. increments) (00 = Off)

75

75

75

B5

On/Off

On or Off

Off

On

Off

Send assigned symbology identifiers* *A = UPC-A B = I 2 of 5 C = Code 39

D = M 2 of 5 E = UPC-E F = S 2 of 5

G = EAN-8 H = MSI I = Codabar

Good-read beep tone

B8

Value

Number of good-read tones

B9

Value Value

Good-read tone duration

BA

J = Code 11 K = Code 128 M = EAN-13

00 = 2400 Hz 02 = 2800 Hz 04 = 3200 Hz 06 = 3600 Hz

N = Labelcode 4/5 O = Ames

00

00

00

01–04

01

01

01

00 = 0.07 sec. 01 = 0.13 sec. 02 = 0.18 sec. 03 = 0.36 sec.

00

00

00

4-5

Page 86

PDT 3200 Product Reference Guide

Code Parameter

Beeper volume

I.D. #

BC

Type

Acceptable Input

Defaults D0

D1

D2

Value

00 = Off 01–09 (01 = Lowest; 07 = Highest; 08 = Higher; 09 = Lower)

07

07

07

01

01

01

Error tone

BD

Value

01 = 2580 Hz 03 = 3000 Hz 05 = 3600 Hz 07 = 4520 Hz

Keypress sound

DD

Value

00 = Off 01 = Click 02 = Beep

01

01

01

Enable CTRL-ALT-DEL reboot

E0

On/Off

On or Off

Off

Off

On

Enable trigger programmability

E1

On/Off

On or Off

On

On

On

Value

01–99 (seconds) (00 = Off)

15

15

15

Backlight auto-off timeout

4-6

E2