The text of a manual · part 2 of 10
Series 3100 Quick Reference, pages 11 to 20
Pages 11 to 20 of 100
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PDT-3100, Symbol PDT-3110 and Symbol PDT-3140
Page 11
11
Replacing the Batteries To replace the NiCd or NiMH battery: 1. Turn the terminal off. 2. Release the hand strap, unlock the battery compartment door and remove it.
Hand Strap
PART NO.: 3100-9M0L050 S/N: B029721 SYMBOL TECH, INC.
PART NO.: 3100-9M0L050
PART NO.: 3100-9M0L050
S/N: B029721 SYMBOL TECH, INC.
S/N: B029721 SYMBOL TECH, INC.
GATES
K•TEC ELECTRONICS HOUSTON
Nickel Cadmium Battery SEALED TYPE-RECHARGEABLE
Battery Adapter
NiCd Battery Battery Compartment Door
Strap Battery Compartment
3. Position the battery adapter in holding plug and press into place. 4. Fit the NiCd or NiMH battery pack in compartment next to adapter. Verify that removal strap is accessible (not tucked under battery), before pressing battery in place. Note:
NiMH batteries cannot be charged in the terminal through the Communications/Charger Adapter.
Page 12
12
5. Verify that battery and adapter are properly seated. 6. Replace and lock battery compartment door. 7. Replace handstrap.
Quick Reference
Page 13
13
Connecting the Modems Direct Connect Some terminals use an optional internal modem that communicates at rates of up to 14,400 bps (with v.32 bis data compression). There are specific firmware settings which are used to configure the modem’s hardware and software for proper operation and regulatory compliance. The terminal’s application can control these settings and enable you to view and amend the settings for country/region, pulse/tone dialing, or repeat dial timing. Incorrectly defining these settings can lead to illegal use of the modem and can create unreliable operation. The application developer should consult the Series 3000 Application Programmer’s Reference Manual for correct settings. If your terminal is equipped with a direct connect modem, connect the modem as follows: 1. Turn the terminal off. 2. Release the hand strap on the back of the terminal.
Page 14
14
3. Detach the protective plug covering the modem jack on the back of the terminal and plug in one of the telephone cord’s connectors.
RJ-41 Jack
4. Plug the cord’s other connector into a telephone jack. 5.
Turn the terminal back on.
Quick Reference
Page 15
15
Acoustic Some Series 3100 terminals are equipped with a built-in acoustic modem which allows direct data transmission over a telephone line. If your terminal is equipped with an acoustic modem, connect the modem as follows: 1. Turn the terminal off. 2. Release the hand strap on the back of the terminal.
3. Slide the mouthpiece of the telephone into position on the muff. Place the hand strap over the telephone handset as shown below and reattach the strap. 4.
Turn the terminal back on.
Page 16
16
Connecting the Terminal to a Printer The Series 3100 has an optional cable (p/n 25-10413-01) which is used to connect the terminal to a PS-1000 Series printer or a tethered PS-200 printer (P/N 20-11062-03). To connect the terminal to one of the printers listed above: 1. Plug the 10-pin RJ41 connector into the base of a Series 3100 terminal. 2.
Plug the DB9 connector in the communications port on the printer.
DB9
RJ-41
Quick Reference
Page 17
17
Using the Integrated Laser Scanner The integrated scanner has a unique trigger that the operator can configure. To select the trigger and use the integrated laser scanner: 1. Power on the system and scanner by pressing PWR or the scanner trigger. 2. Lift and turn the scanner to the direction you wish to scan. The scanner turns toward the back of the terminal.
3. Press the FUNC key and the trigger you are most comfortable using (see the figure below). This selects the scanner trigger. The other trigger defaults to an ALPHA shift key on the 35-key terminal.
Page 18
18
4. Point the scanner at the bar code and press the trigger or press the soft trigger key (ENTER). The thin, red laser beam covers the entire length of the bar code.
The terminal indicates a successful scan by illuminating the green scanner LED, beeping one or more times, and/ or displaying the decoded bar code on the screen.
Quick Reference
Page 19
19
Connecting and Using a Tethered Scanner To attach a wand or laser scanner to the Series 3100 terminal: 1. Turn the system off. 2. Remove the plastic cap in the top of the terminal. 3. Plug the scanner into the top of the terminal as shown below.
4.
Aim the scanner at the bar code and press the trigger.
Note:
Depending on your application, you may need to turn on the terminal before using the scanners.
5. If using a wand scanner, lightly touch the scanner tip to the white space at the left side of the bar code and move it to the right.
Page 20
20
IEC825/EN60825 Class 1 Scanner Series 3100 terminals are equipped with an IEC825/EN60825 scanner operate on an emissions accumulator or “gas tank” which determines the amount of scan time that you have available. To meet low power consumption standards, the scanner cannot scan continuously. If the gas tank runs out of scan time, the terminal emits a long low beep. Release the scan trigger and wait until the terminal emits a long high beep, indicating that it accrued enough scan time for you to resume scanning.
Guide utilisateur