Page 9
Q u i c k
R e f e r e n c e
Scanner confirmation LED (green when bar code is successfully read). The trigger switch function is assigned to all the M keys at the factory.
Max. 56 cm. (22 inches) 35864001.eps
7
Page 10
P
D
T
1
1
0
0
Hand Strap and Pocket Clip (optional) Loop the hand strap through the terminal, then put your hand through the strap and hold the PDT 1100. This prevents you from accidentally dropping the terminal.
Hand Strap
Attaching the Clip First fit the left tab of the clip into the matching groove of the PDT 1100 body and then snap the other tab into place. To remove the clip, insert a flat-edged screwdriver at the edge and twist to disengage.
35864004.eps
Setting the Backlight The backlight function is off when the terminal is powered on. Press the M1 key while holding down the SF (shift) key to activate or deactivate the backlight function. Note:
In application programs, you can redefine the key to be used for activating or deactivating the backlight func8
Page 11
Q u i c k
R e f e r e n c e tion. You can also modify the time before automatic shut-off.
Adjusting Settings The LCD brightness can be adjusted between eight contrast levels. The terminal can be set in both beeper and vibration alert modes, and the volume can be adjusted between four levels.
Adjusting the LCD Contrast 1. Press M1, hold it down and press PW to display the LCD Contrast screen. 2. Use F5 or F6 keys to select the LCD contrast line in the display. 3. To decrease the contrast, press F7. 4. To increase the contrast, press F8. 5. Press the Enter key, or wait 5 seconds to accept the new setting.
Using Beeper and Vibration Modes The PDT 1100 has three ways to inform you that a bar code has been scanned successfully: • confirmation LED • beeper mode • vibration mode The confirmation LED and beeper are the default methods of announcing successful scans. Beeper and vibration modes can be used simultaneously.
Adjusting the Beeper Volume The beeper volume can be adjusted to four levels, from OFF to MAX. 1. Press and hold M1. Press and release PW to display the Beeper Volume Screen. 9
Page 12
P
D
T
1
1
0
0
2. Use F5 or F6 keys to select the beeper volume line in the display. 3. To lower the volume, press F7. 4. To raise the volume, press F8. 5. Press the Enter key, or wait 5 seconds to accept the new setting.
Switching the Beeper/Vibration Mode You can set the terminal to beep, vibrate, or do both upon a successful scan. 1. Press and hold M1. Press and release PW to display the Beeper/Vibration mode screen. 2. Use F5 or F6 keys to select the Switching Beeper Volume line. 3. Press the F7 key twice to select Beeper mode. 4. Press the F8 key twice to select Vibration mode. 5. Press the F8 key once to select both Beeper and Vibration. 6. Press the Enter key, or wait 5 seconds to accept the new setting.
Setting the Date and Time 1. Hold down the SF and 1 keys and press the PW key to display the SYSTEM MENU screen. 2. Select 4:SET SYSTEM and press the ENT key to display the SET SYSTEM screen. 3. Select 3:DATE/TIME and press the ENT key to display the SET DATE/TIME screen. 4. Use numeric keys and enter the year (only the two last digits), month, day, hour (in 24-hour format) and then minutes. Add a 0 (zero) preceding one digit entries. 5. If you make an incorrect entry, press the BS key and enter the correct data. 10
Page 13
Q u i c k
R e f e r e n c e
6. Press the C key to return to the SET SYSTEM screen.
Using the Keypad Entering Numeric Data To enter numeric data, e.g., the quantity of goods, use the ten numeric keys and the Enter key. If you key in a wrong value, press the C key to clear, or the BS (Backspace) key and enter the correct data.
Selecting Tasks If the LCD shows the selection (xxx) prefaced by a number (i.e., 1: xxx, 2:xxx), use the numeric keys to select the desired item, then press the Enter key to execute. If a YES/NO screen (e.g., 1:Yes, 2:No) appears, respond by pressing 1 for yes, 2 for no.
Entering Alphabetic Characters The PDT 1100 supports the alphabet input function using letters, characters and spaces from the keypad during execution of an application program. Refer to the PDT 1100 Product Reference Guide (p/n 70-35864-xx) for more information.
Communications There are three options for transmission of data. • • •
CRD 1100 cradle Optical interface Serial cable
Using the Cradle (CRD 1100) The optional CRD 1100 is an infrared communications unit with optional charging function. You may either keep the PDT 1100 and the CRD 1100 separated by 10-80 cm (4-30 inches) with their IR
11
Page 14
P
D
T
1
1
0
0 ports facing each other, or put the PDT 1100 directly in the cradle to communicate through the cable.
35864008.eps
Using the Optical Interface The PDT 1100 communicates using a beam of infrared light, so there should be nothing obstructing the line of sight between the terminal and any target stations. In the IrDA communications mode, keep the terminal and target within the effective light emission range, about 10-80 centimeters (4-30 inches). The PDT 1100 can also communicate with other equipment with infrared capability. This is done by aligning the infrared ports. The effective IR range and IR port angle may differ depending upon the target equipment, so refer to all relevant instruction manuals.
Using the Serial Cable The PDT 1100 can also be connected directly to a host computer, a modem, or a printer with the optional RS-232C direct-connect serial cable. For more information on cable connection and communications, refer to the PDT 1100 Product Reference Guide (p/n 70-35864xx).
12
Page 15
Q u i c k
R e f e r e n c e
Batteries Types of Batteries The PDT 1100 accepts either two standard AAA batteries or a rechargeable NiMH battery pack (optional). The batteries are not loaded into the terminal when it is shipped from the factory. Note:
For best battery performance at low temperatures (at or below 0°C or 32°F) we recommend using the optional rechargeable NiMH battery pack.
Loading the Batteries AAA Alkaline Batteries 1. Turn the PDT 1100 upside down. Slide the cover lock in the direction of the arrow and remove the battery cover. 2. Check the polarity of the two new batteries and insert them so that the end of the battery pull strap is above the batteries. This facilitates easy removal of the batteries. 3. Replace the battery cover, being careful not to pinch the battery pull strap between its cover and the bottom cover. Return the battery cover lock to its original locked position. NiMH Battery Pack 1. Charge the NiMH battery pack in the cradle battery charging slot prior to installing it in the terminal (refer to Using the Cradle to Charge the NiMH Battery Pack on page 15). 2. Turn the PDT 1100 upside down. Slide the cover lock in the direction of the arrow and remove the battery cover. 3. Check the polarity of the battery pack. Load it so that the end of the battery pull strap appears above the battery pack. This facilitates easy removal of the battery pack. Make certain grooves on the battery pack are aligned with the slot. 4. Replace the battery pack cover, being careful not to pinch the battery pull strap between its cover and the bottom cover. 13
Page 16
P
D
T
1
1
0
0
Return the battery cover lock to its original locked position.
Charging the Super Cap When powering up for the first time, or when the batteries are out of the terminal for five minutes or more, the super cap must be fully charged to provide memory backup. To fully charge the super cap, insert fresh batteries and allow two hours for the batteries to charge the super cap. If this is not done, there may not be sufficient backup power to maintain data. There is no indication on the terminal when the super cap is charging.
Voltage Indication To check the current voltage: 1. Press the Enter key while holding down the SF key. The current voltage is displayed as a bar in the LCD window. 2. Release the keys to delete the indication. For more details, refer to the PDT 1100 Product Reference Guide (p/n 70-35864-xx).
Low Battery Indication If the voltage drops below specific levels while the PDT 1100 is in operation, the unit displays two warning messages. The first warning message is: Battery Voltage has Lowered.
The unit then beeps three times and resumes normal operation. This message means that the batteries will expire soon. If you do not replace the batteries within a short time, the terminal shows one of the following two messages, beeps five times, and shuts down automatically. For AAA alkaline batteries: Replace the Batteries!
14