Page 301
Function Reference
TIME$ Function Name: TIME
Type: I/O Function
Description Returns the current system time or wake-up time, or sets a specified system time or wake-up time.
Syntax Syntax 1 (Retrieving the current system time or the wake-up time) TIME$
Syntax 2 (Setting the current system time or the wake-up time) TIME$=”time” where: time = A string expression.
Notes Syntax 1 !
Retrieving the current system time
TIME$ returns the current system time as an 8-byte string. The string has the format below. hh:mm:ss where hh is the hour from 00 to 23 in 24-hour format, mm is the minute from 00 to 59, and ss is the second from 00 to 59. Example:
CLS PRINT TIME$
Retrieving the wake-up time TIME$ returns the wake-up time as a 5-byte string. The string has the format below. !
hh:mm
11-53
Page 302
PDT 1100 Terminal Programmer’s Guide
Syntax 2 Setting the system time TIME$ sets the system time specified by “time.” The format of “time” is the same as that in syntax 1. !
Example: !
TIME$=“13:35:45”
Setting the wake-up time
TIME$ sets the wake-up time specified by “time.” The format of “time” is the same as that in syntax 1. "
The calendar clock is backed up by the battery. (For the system date, refer to the DATE$ function.) " Set bit 2 of port 8 to 1 with the OUT statement before executing this function to return the current wake-up time or set a specified wake-up time. " For the wake-up function, refer to Appendix H, Programming Notes.
Execution Error Error code
Meaning
05h
Parameter out of range (time is out of range.)
Reference Functions
11-54
DATE$
Page 303
Function Reference
TIMEA/TIMEB/TIMEC Function Name: TIMER-A/TIMER-B/TIMER-C
Type: I/O Function
Description Returns the current value of a specified timer or sets a specified timer.
Syntax Syntax 1 (Retrieving the current value of a specified timer) TIMEA TIMEB TIMEC
Syntax 2 (Setting a specified timer) TIMEA= count TIMEB= count TIMEC= count where: count = A numeric expression which returns a value from 0 to 32,767.
Notes Syntax 1 TIMEA, TIMEB, or TIMEC returns the current value of timer-A, -B, or -C, respectively, as a 2byte integer.
Syntax 2 TIMEA, TIMEB, or TIMEC sets the count time specified by count. !
count is a numeric value in units of 100 ms.
!
When executed, the Interpreter starts a specified timer counting down in increments of 100 ms (equivalent to -1) until the timer value becomes 0.
11-55
Page 304
PDT 1100 Terminal Programmer’s Guide
Execution Error Error code
Meaning
05h
Parameter out of range ( count is a negative value)
06h
The operation result is out of the allowable range ( count is greater than 32,767.)
11-56
Page 305
Function Reference
VAL Function Name: VALue
Type: String Function
Description Converts a string into a numeric value.
Syntax VAL(stringexpression)
where: stringexpression = A string expression which represents a decimal number.
Notes VAL converts the string specified by stringexpression into a numeric value. !
If stringexpression is nonnumeric, VAL returns the value 0. PRINT VAL(“ABC”) 0
!
If stringexpression contains a nonnumeric in midstream, VAL converts the string until it reaches the first character that cannot be interpreted as a numeric. PRINT VAL(“1.2E-3ABC”) 1.200000000E-3
!
The STR$ function has the opposite capability to VAL.
Reference Functions
ASC and STR$
11-57
Page 306
Appendix A Error Codes and Error Messages Introduction This Appendix specifies all error codes and their meanings
Execution Errors Table A-1 lists the execution errors codes and their meanings. Table A-1. Execution Errors Error Code
Meaning
00h
Internal system error
01h
NEXT without FOR
02h
Syntax error
03h
RETURN without GOSUB
04h
Out of DATA (no DATA values remain to be read by the READ instruction)
05h
Parameter out of range
06h
Operation result is out of the allowable range
07h
Insufficient memory space (too many nesting levels, etc)
08h
Array not defined
09h
Subscript out of range (an array subscript is out of the array, or the array is referenced by different dimensions)
A-1
Page 307
PDT 1100 Terminal Programmer’s Guide
Table A-1. Execution Errors (Continued) Error Code
A-2
Meaning
0Ah
Duplicate definition (an array is defined twice)
0Bh
Division by zero
0Ch
CASE and END SELECT without SELECT
0Dh
END DEF or EXIT DEF instruction executed outside the DEF EN statement block
0Fh
String length out of range
10h
Expression too long or complex
14h
RESUME without error (RESUME instruction occurs before the start of an errorhandling routine)
1Fh
Function number out of range (in CALL statement)
32h
File type mismatch
33h
Received text format not correct
34h
Bad file name or number (an instruction uses the file number of an unopened file)
35h
File not found
36h
Improper file type (instruction attempts an operation that conflicts with the file type – data file, communications device file, or bar code device file)
37h
File already open (an OPEN instruction executed for the already opened file)
38h
File name is different from that in the receive header
39h
Too many files
3Ah
File number out of range
3Bh
The number of records is greater than the defined maximum value
3Ch
FIELD overflow (FIELD instruction specifies the record length exceeding 255 bytes)
3Dh
FIELD statement specifies a field width which does not match that specified in file creation
3Eh
PUT or GET instruction executed without a FIELD instruction
3Fh
Bad record number (record number is out of range)
Page 308
Error Codes and Error Messages
Table A-1. Execution Errors (Continued) Error Code
Meaning
40h
Parameter not set (ID not set)
41h
File damaged
42h
File write error (writing onto a read-only file attempted)
43h
Not allowed to access data in flash ROM
45h
Device files prohibited from opening concurrently
46h
Communications error
47h
Abnormal end of communications or termination of communications by Clear key
48h
Device timeout (n o CS signal has been responded within the specified time period)
Fatal Errors Table A-2 lists the fatal errors and their meanings. Table A-2. Fatal Errors Error Code
Message fatal error 1:
Out of memory fatal error 2:
Work file I/O error fatal error 3:
Object file I/O error fatal error 4:
Token file I/O error fatal error 5:
Relocation information file I/O error fatal error 6:
Cross reference file I/O error fatal error 7:
Symbol file I/O error fatal error 8:
Compile list file I/O error fatal error 9:
Debug information file I/O error (source-address)
fatal error 10:
Debug information file I/O error (label-address)
fatal error 11:
Debug information file I/O error (variable-intermediate code)
A-3
Page 309
PDT 1100 Terminal Programmer’s Guide
Table A-2. Fatal Errors (Continued)
A-4
Error Code
Message fatal error 12:
Out of disk space for work file fatal error 13:
Out of disk space for object file fatal error 14:
Out of disk space for token file fatal error 15:
Out of disk space for relocation information file fatal error 16:
Out of disk space for cross reference file fatal error 17:
Out of disk space for symbol file fatal error 18:
Out of disk space for compile list file fatal error 19:
Out of disk space for debug information file (source-address)
fatal error 20:
Out of disk space for debug information file (label-address)
fatal error 21:
Out of disk space for debug information file (variable-intermediate code)
fatal error 22:
Source file I/O error fatal error 23:
Cannot find XXXXSRC fatal error 24:
Error count exceeds 500 fatal error 25:
Out of memory (internal labels exceed 3000)
fatal error 26:
Control structure nesting exceeds 30 fatal error 27:
Expression type stack exceeds 50 fatal error 28:
Program too large (object area over-flow)
fatal error 29:
Out of memory for cross reference fatal error 30:
Cannot find include file fatal error 31:
Cannot nest include file