Page 45

Quick Tour

Menu Options 1. Click to set the scanner menu keys. The Menu List dialog box (Figure 2-11) appears.

Figure 2-11. Menu List Window 2. In the Menu Options area, type SCAN DATA. 3. In the Shortcut area, click on the list box and select F1. 4. In the Goto Program area, click on the list box and select S02 - SCREEN 2. Thi enables the SCAN DATA program to run when the F1 key is pressed. 5. Click to accept the information. 6. The Menu design is complete and a program can now be designed.

2-9

Page 46

MCL-Designer for Phaser Series User’s Guide

Designing a Program This section provides the steps required to create a small program. This program allows the operator to enter a barcode and input keyboard data. 1. In the MCL Designer window, click the Main tab.

Figure 2-12. MCL Designer - MainTa 2. Click on the Main Program button for the first Program (1). The Program Designer window (Figure 2-13) appears.

2-10

Page 47

Quick Tour

Figure 2-13. Program Designer Window

Display Text - Screen 1 1. In the Program Designer window, click (Figure 2-14).

to display the Display Text dialog box

2. In the Display Text box, type: SCAN BARCODE.

Figure 2-14. Display Text Dialog Box

2-11

Page 48

MCL-Designer for Phaser Series User’s Guide

3. Click to accept the information. 4. A cursor,with pages attached, appears on the Menu Screen. Position the cursor over the first line. 5. Click the left mouse button to place the text box on the screen.

Display Text - Screen 2 1. Click to switch to Screen 2.

2. Click to display the Display Text dialog box.

3. In the Display Text box, type: Code:.

Figure 2-15. Display Text Dialog Box 4. Click to accept the information. 5. A cursor,with pages attached, appears on the Menu Screen. Position the cursor over the left side of the first line in Screen 2. 6. Click the left mouse button to place the text box on the screen.

2-12

Page 49

Quick Tour

Barcode Input 1. Click to open the Barcode Input dialog box.

Figure 2-16. Barcode Input Dialog Box - Input Tab 2. In the Input tab, click on to open the

Variables dialog box.

Figure 2-17. Variables Dialog Box 3. Click on the A0 cell and in the Variable Name column, type: CODE.

2-13

Page 50

MCL-Designer for Phaser Series User’s Guide

4. Click to accept the information. 5. In the Select Entry Type(s)area, click on the UPC -A, UPC-E0, UPC-E1, EAN 13, EAN 8, PDF 417 and Keyboard check boxes. 6. In the Input Length area, select 1 for Minimum and 13 for Maximum 7. In the Option area, click on the Numeric only check box. 8. In the Validation area, click on the Auto Enter radio button to allow barcode input without clicking the Enter key.

Hot Keys 1. In the Barcode Input dialog box, choose the Hot Keys tab.

Figure 2-18. Barcode Input Dialog Box - Hot KeysTab 2. In the Other Keys area, click on the Clear list box and select Exit. 3. Click to accept the information. 4. A cursor,with pages attached, appears on the screen. Position the cursor to the right of the word CODE in the first line in Screen 2. 5. Click the left mouse button to place the text box on the screen.

2-14

Page 51

Quick Tour

Display Text - Screen 3 1. Click to switch to Screen 3 2. Click to display the Display Text dialog box.

Figure 2-19. Display Text Dialog Box 3. In the Display Text box, type: Qty:. 4. Click to accept the information. 5. A cursor,with pages attached, appears on the screen. Position the cursor over the left side of the first line in Screen 3. 6. Click the left mouse button to place the text box on the screen.

2-15

Page 52

MCL-Designer for Phaser Series User’s Guide

Keyboard Input 1. Click to open the Keyboard Input dialog box.

Figure 2-20. Keyboard Input Dialog Box -Input Tab 2. In the Input tab, click to open the

Variables dialog box.

Figure 2-21. Variables Window 3. Click on the A1 cell and in the Variable Name column, type: QTY. 4. Click to accept the information. 5. In the Input Type area, click on the Numeric radio button. 6. In the Default Value area, type: 1. 2-16