Page 267

MCL-Code Reference Guide

Table 7-6. System Setup Variables (Continued) Variable

Default Value

20 Y Y N Y Y N Y Y N Y N N N N N Y 24

0070137013

Description Bar-code type mask: Y = enable, N = disable. Contains a 16 characters mask (one character per symbology). char. 1 = UPC A (leftmost character). char. 2 = UPC E0. char. 3 = UPC E1. char. 4 = EAN13. char. 5 = EAN 8. char. 6 = Standard 2/5. char. 7 = Interleave 2/5. char. 8 = Code 39. char. 9 = CODABAR. char. 10 = Code 128. char. 11 = Code 93. char. 12 = Code 11. char. 13 = MSI. char. 14 = Code 49. char. 15 = PDF417. char. 16 = EAN128 (rightmost character). Scan Options Control: Variable which controls the format of data as transmitted from the default application. Note that unless the user specifically writes code to utilize this variable, the scan options control affects ONLYthe default application. The format of this variable is: wxyyyyzzzz where: w x is the enable code for data prefix (0 is disabled, 1 is enabled) is the enable code for data suffix (0 is disabled, 1 is enabled) is the keycat/keycode of the data prefix is the keycat/keycode of the data suffix yyyy zzzz For example: 0170137013 Specifies that data will be transmitted with a suffix of CR/LF (as specified by keycat/keycode 7013). * : Read Only variable

7-99

Page 268

MCL-Designer for Phaser Series User’s Guide

Table 7-6. System Setup Variables (Continued) Variable

Default Value

Description

25

1

Keyboard Click: 0 = Off. 1 = On.

27

4

Display Contrast 0 = Least Contrast (lightest). 7 = Most Contrast (darkest).

28

512

System Memory size, in KB*. 512 = 512 KB 1024 = 1024 KB (1 MB). 4096 = 4096 KB (4 MB). 8192 = 8192 KB (8 MB). Note that 256KB of the memory is allocated for system code and user scripts on the 512 KB and 1 MB scanners, while 512 KB of the memory is allocated on the 4 MB and 8 MB scanners. So, on a 512 KB scanner, only 256 KB is available for data storage.

29

0

Address format used by MCL-Net: 0 = decimal addresses. 1 = Hexadecimal addresses.

30

10

Power off delay in seconds.

33

0

Power source:* 0 = batteries. 1 = cradle. 2 = cable.

35

Batteries status: * 0 = good. 1 = low. 2 = dead.

40

Hours from internal clock system: format 00 to 23 *.

41

Minutes from internal clock system: format 00 to 59 *.

42

Seconds from internal clock system: format 00 to 59 *.

* : Read Only variable

7-100

Page 269

MCL-Code Reference Guide

Table 7-6. System Setup Variables (Continued) Variable

Default Value

Description

43

Day from internal clock system: format 01 to 31 *.

44

Month from internal clock system: format 01 to 12 *.

45

Year from internal clock system: format 1980 to 2079 *.

46

Julian day: format 001 to 365 *.

52

Date Format: 1 = Not Used. 2 = Not Used. 3 = MM DD YYYY 4 = DD MM YYYY

53

1

Date Separator: 1=/ 2=3=: 4 = no separator.

54

1

Hour format: 1 = 24 2 = 12

55

0

Decimal separator: 0=. 1=,

56

4*

TF_type = Supported TF (file transfer) format (scanner to host). 0= TF Extended (Binary format support). 3= TF Counter size in 3 digits. 4= TF Counter size in 4 digits (Default value).

59

’ | ‘(ASCII 124)

68

None

70

Field separator. Program number of currently active program (0 - 8). Version information:* NBRVSMxx, where xx is AA, AB, AC, ... BA, BB, ... to indicate revision level of scanner code.

* : Read Only variable

7-101

Page 270

MCL-Designer for Phaser Series User’s Guide

Table 7-6. System Setup Variables (Continued) Variable

Default Value

Description

71

Scanner Identification number (001 to 254).

72

Date and time in format CCYYMMDDHHMMSS.

73

Date MM/DD/YY (depending on code page).

74

Time HH:MM:SS.

75

Day of week (0 = Sunday, 1 = Monday, .....).

76

AM/PM *.

78

None

Week number for the current date (1 - 53)

85

MCL Interpreter version x.x *.

86

Not supported.

89

Version date * format: formatted according to the Date Format and Date Separator parameters

90-99 * : Read Only variable

7-102

Various return codes from MCL commands.

Page 271

MCL-Code Reference Guide

PY Parameter Numbers The following table (Table 7-7) lists the PY Parameter Numbers. Table 7-7. PY Parameter Number Parameter

Parameter Number

Options

Default Value

Code 39 Code 39

0x00

0 Disable 1 Enable

Enable

Code 39 Length 1

0x12

2

Code 39 Length 2

0x13

Any length (len1 = len2 = 0) Range (len2 > len1) Discrete lengths (len1 > len2)

Verify Code 39 Check Digit

0x30

0 Disable 1 Enable

Disable

Transmit Code 39 Check Digit 0x2B

0 Do Not Transmit 1 Transmit

Do Not Transmit

Code 39 Full ASCII

0x11

0 Disable 1 Enable

Disable

Convert Code 39 to Code 32

0x56

0 Disable 1 Enable

Disable

Code 32 Prefix

0xe7

0 Disable 1 Enable

Disable

Trioptic Code 39

0x0

0 Disable 1 Enable

Disable

55

UPC/EAN UPC-A

0x01

0 Disable 1 Enable

Enable

UPC-E

0x02

0 Disable 1 Enable

Enable

EAN-13

0x03

0 Disable 1 Enable

Enable

7-103

Page 272

MCL-Designer for Phaser Series User’s Guide

Table 7-7. PY Parameter Numbers (Continued) Parameter

Parameter Number

Options

Default Value

UPC/EAN - Continued EAN-8

0x04

0 Disable 1 Enable

Enable

UPC-E1

0x0C

0 Disable 1 Enable

Disable

Bookland EA

0x53

0 Disable 1 Enable

Disable

Coupon

0x55

0 Disable 1 Enable

Disable

Decode UPC/EAN Supplementals

0x10

0 Ignore Supps 1 Decode Supps only 2 Auto-discriminate Supps

Ignore Supps

Supplementals Redundancy

0x50

2-20

7

Transmit UPC-A Check Digit

0x28

0 Disable 1 Enable

Enable

Transmit UPC-E Check Digit

0x29

0 Disable 1 Enable

Enable

Transmit UPC-E1 Check Digit 0x2A

0 Disable 1 Enable

Enable

UPC-A Preamble

0x22

0 None 1 System Character 2 System Character and Country Code

System Character

UPC-E Preamble

0x23

0 None 1 System Character 2 System Character and Country Code

System Character

7-104

Page 273

MCL-Code Reference Guide

Table 7-7. PY Parameter Numbers (Continued) Parameter

Parameter Number

Options

Default Value

UPC/EAN - Continued UPC-E1 Preamble

0x24

0 None 1 System Character 2 System Character and Country Code

System Character

Convert UPC-E to UPC-A

0x25

0 Disable 1 Enable

Disable

Convert UPC-E1 to UPC-A

0x26

0 Disable 1 Enable

Disable

EAN-8 Zero Extend

0x27

0 Disable 1 Enable

Disable

EAN-8 to EAN-13 Type

0xE0

0 Type is EAN-13 1 Type is EAN-8

Type is EAN-13

UPC/EAN Security Level

0x4

0-3

0

Discrete 2 of 5 Discrete 2 of 5

0x05

0 Disable 1 Enable

Disable

Discrete 2 of 5 Length 1

0x14

12

Discrete 2 of 5 Length 2

0x15

Any length (len1 = len2 = 0) Range (len2 > len1) Discrete lengths (len2 < len1)

0

Interleaved 2 of 5 Interleaved 2 of 5

0x06

0 Disable 1 Enable

Enable

Interleaved 2 of 5 Length 1

0x16

14

Interleaved 2 of 5 Length 2

0x17

Any length (len1 = len2 = 0) Range (len2 > len1) Discrete lengths (len2 < len1)

Verify I 2 of 5 Check Digit

0x31

0 None 1 USS Check Digit 2 OPCC Check Digit

0 None

7-105

Page 274

MCL-Designer for Phaser Series User’s Guide

Table 7-7. PY Parameter Numbers (Continued) Parameter

Parameter Number

Options

Default Value

Interleaved 2 of 5 - Continued Transmit I 2 of 5 Check Digit

0x2C

0 Do not transmit 1 Transmit

Do not transmit

Convert I 2of 5 to EAN-13

0x52

0 Disable 1 Enable

Disable

Codabar Codabar

0x07

0 Disable 1 Enable

Disable

Codabar Length 1

0x18

5

Codabar Length 2

0x19

Any length (len1 = len2 = 0) Range of lengths (len2 > len1) Discrete Lengths (len2 < len1)

CLSI

0x36

0 Disable 1 Enable

Disable

Notis

0x37

0 Disable 1 Enable

Disable

55

Code 128 Code 128

0x08

0 Disable 1 Enable

Enable

EAN-128

0x0E

0 Disable 1 Enable

Enable

Code 93 Code 93

0x09

0 Disable 1 Enable

Disable

Code 93 Length 1

0x1A

4

Code 93 Length 2

0x1B

Any length (len1 = len2 = 0) Range of lengths (len2 > len1) Discrete Lengths (len2 < len1)

7-106

55

Page 275

MCL-Code Reference Guide

Table 7-7. PY Parameter Numbers (Continued) Parameter

Parameter Number

Options

Default Value

Code 11 Code 11

0x0A

0 Disable 1 Enable

Disable

Code 11 Length 1

0x1C

4

Code 11 Length 2

0x1

Any length (len1 = len2 = 0) Range of lengths (len2 > len1) Discrete Lengths (len2 < len1)

Verify Code 11 Check Digit

0x34

0 Disable 1 Enable

Disable

0 Do not transmit 1 Transmit

Do not transmit

Transmit Code 11 Check Digit 0x2F

55

MSI MSI

0x0B

0 Disable 1 Enable

Disable

MSI Length 1

0x1E

1

MSI Length 2

0x1F

Any length (len1 = len2 = 0) Range of lengths (len2 > len1) Discrete Lengths (len2 < len1)

MSI Check Digits

0x32

0 One check digit 1 Two check digits

One check digit

MSI Check Digit Scheme

0x33

0 Mod-11, Mod-10 1 Mod-10, Mod-10

Mod-10, Mod-10

Transmit MSI Check Digit

0x2E

1 Transmit 0 Do not transmit

Do not transmit

55

General Transmit Options Transmit Code ID

0x2

0 None 1 AIM ID’s 2 Symbol ID’s

None

Transmit “No Read” Characters

0x5E

0 Disable 1 Enable

Disable

7-107

Page 276

MCL-Designer for Phaser Series User’s Guide

Table 7-7. PY Parameter Numbers (Continued) Parameter

Parameter Number

Options

Default Value

General Laser On Timeout

0x88

5 – 99 (1/10 second units)

30 (3 seconds)

General Decode Parameters Bi-directional Redundancy

0x43

0 Disable 1 Enable

Disable

Linear Security Level

0x4E

1-3

1

Beeper/User Interface Parameters Beep on Good Decode (for use 0x38 by default application)

0 Disable 1 Enable

Enable

Beeper Volume

0x8C

0 High 1 Medium 2 Low

High

Beeper Frequency

0x91

0 High 1 Medium 2 Low

High

Primary Serial Port Parameters Response Timeout

0x9B

5 – 99 (1/10 second units)

20 (2 seconds)

Baud Rate

0x9C

2 = 600 3 = 1200 4 = 2400 5 = 4800 6 = 9600 7 = 19200 8 = 38400

9600

Stop Bits

0x9

1 = 1 stop bit 2 = 2 stop bits

1 stop bit

7-108