Page 177

MCL-Code Reference Guide

Table 7-3. Logical Group, Command, and Description (Continued) Logical group Parameters

Miscellaneous

Compute Commands

Command

Description

Page

PI Parameterize Input

Sets the input time-out value and exit keys for all 7-60 subsequent input operations.

PT Parameterize Time

Sets the date and time.

7-62

PX Change Syst. Var

Changes System variable.

7-63

PY Change Parameter

Changes scanner parameter based on parameter number and value.

7-64

BP Beep

Emits a “beep” tone during a user-defined time interval.

7-11

WT Wait

Suspends program execution for a pre-defined delay time.

7-94

CP CRC ComPute CRC Compute various CRCs of the given string as a 5 7-13 digit integer from 00000 to 65535. CP XOR ComPute XOR Compute XOR checksum of given string as a five 7-15 digit integer. CP CVT ComPute ConVerT

This function provides useful conversions.

7-16

7-9

Page 178

MCL-Designer for Phaser Series User’s Guide

Backlight (BL) Function Controls the backlight on the scanner screen.

Syntax BL | parameter where:

Parameter = backlight setting. ON = backlight ON. OFF = backlight OFF. time = backlight on for specified number of seconds (1 to 255 seconds).

Affected System Variables None

Note This command is reserved for future use; the present Phaser design does not incorporate a backlight.

Examples BL | 5

Sets backlight ON for 5 seconds.

BL | ON

Sets backlight ON.

BL | OFF

Sets backlight OFF.

7-10

Page 179

MCL-Code Reference Guide

Beep (BP) Function Emits a specified beep sequence.

Syntax BP | index where: Index = index into the predefined table.

Affected System Variables None

Parameters index: Index into the predefined table.

Notes The beep table is defined as follows: Table 7-4. Beep Sequen c e Beep Description

Beep Index

1 Short High Beep

0

2 Short High Beeps

1

3 Short High Beeps

2

4 Short High Beeps

3

5 Short High Beeps

4

1 Short Low Beep

5

2 Short Low Beeps

6

3 Short Low Beeps

7

4 Short Low Beeps

8

5 Short Low Beeps

9

7-11

Page 180

MCL-Designer for Phaser Series User’s Guide

Table 7-4. Beep Sequences (Continued) Beep Description

Beep Index

1 Long High Beep

10

2 Long High Beeps

11

3 Long High Beeps

12

4 Long High Beeps

13

5 Long High Beeps

14

1 Long Low Beep

15

2 Long Low Beeps

16

3 Long Low Beeps

17

4 Long Low Beeps

18

5 Long Low Beeps

19

4 Short Beeps ---- High – Low – High – Low

20

4 Long Beeps ---- High – Low – High – Low

21

2 Short Beeps ---- High – Low

22

2 Short Beeps ---- Low – High

23

3 Short Beeps ---- High – Low – High

24

3 Short Beeps ---- Low – High – Low

25

4 Long Beeps ---- High – High – Low – Low

26

4 Long Beeps ---- Low – High – Low – High

27

3 Long Beeps ---- Low – High – Low

28

3 Long Beeps ---- High – Low – Low

29

3 Long Beeps ---- Low – High – High

30

4 Long Beeps ---- High – High – High – Low

31

Decode Beep

32

Examples BP | 32

7-12

Generate a decode beep.

Page 181

MCL-Code Reference Guide

ComPute CRC (CP CRC) Function Compute various CRCs of the given string as a 5 digit integer from 00000 to 65535.

Syntax CP | CRC | variable| string | optio where:

Variable = variable receiving value String = input character string Option = specific CRC algorithm 0: MCL-CRC1 1: CCITT 2: CRC1 3: Alternative CRC-16 (with sum initialized to 0x0000) *default: MCL-CRC1 (If no option is selected, the terminal defaults to the MCL-CRC16 algorithm.)

Affected System Variables None

Note Use the command CP|CVT to convert the result of this operation in the desired format.

Examples CP | CRC | A0 | Mouse House | 0 After this operation, the variable A0 will contain 59010 CP | CRC | A0 | Mouse House

7-13

Page 182

MCL-Designer for Phaser Series User’s Guide

After this operation, the variable A0 will contain 59010 CP | CRC | A0 | The hazy sky | 1 After this operation, the variable A0 will contain 59802 CP | CRC | A0 | 02343499 | 2 After this operation, the variable A0 will contain 64622 CP | CRC | A0 | Mouse House | 3 After this operation, the variable A0 will contain 64891

7-14

Page 183

MCL-Code Reference Guide

ComPute XOR (CP XOR) Function Compute XOR checksum of given string as a five digit integer. (Use CP | CVT to convert in another format.)

Syntax CP | XOR | variable | string where:

Variable = variable receiving value String = input character string

Affected System Variables None

Note Use the command CP | CVT to convert the result of this operation in the desired format.

Examples CP | XOR | A0 | Mouse House After this operation, the variable A0 will contain 00218 CP | XOR | A0 | 900345 After this operation, the variable A0 will contain 00244

7-15

Page 184

MCL-Designer for Phaser Series User’s Guide

ComPute ConVert (CP CVT) Function This function provides useful conversions.

Syntax CP | CVT | variable | type | string where:

Variable = variable receiving value Type = type of conversion 0 = convert a char to this ASCII value or convert a string to the sum of ASCII values of each character 1 = get a number as an ASCII code and convert it to a character 2 = convert a number to a string of 2 hexadecimal digit 3 = convert a number to a string of 4 hexadecimal digit 4 = converts a number to a string of 2 characters as used by MCLNet protocol for checksums 5 = converts a number to a string of 4 characters as used by MCLNet protocol for checksums 6 = convert a string of hexadecimal digits to a decimal number (of 5 digits) 7 = convert a string of MCL-Net checksum digits to a decimal number String = input character string or numbe

7-16

Page 185

MCL-Code Reference Guide

Affected System Variables &99 =

0, if conversion is OK. Variable = returns value of conversion. 1, if the number or string cannot be converted. Variable = "?"

Examples CP | CVT | A0 | 0 | X Convert char to an ASCII code. A0 will contain the ASCII code of X = 0008 CP | CVT | A0 | 0 | ABCDE Convert a string to the sum of ASCII codes. A0 will contain the ASCII code of X = 00335 CP | CVT | A0 | 1 | 88 Convert an ASCII code to a character. A0 will contain the character CP | CVT | A0 | 2 | 186 Convert to 2 hexadecimal digits. A0 will contain BA CP | CVT | A0 | 3 | 186 Convert to 4 hexadecimal digits. A0 will contain 00BA CP | CVT | A0 | 2 | 2576 Var 99 = 1 because 25761 cannot be converted to 2 hexadecimal digits. A0 = "?" CP | CVT | A0 | 4 | 186 Convert to 2 MCL-Net checksum characters. A0 will contain ;: CP | CVT | A0 | 5 | 186 Convert to 4 MCL-Net checksum characters. A0 will contain 00;:

7-17

Page 186

MCL-Designer for Phaser Series User’s Guide

CP | CVT | A0 | 4 | 2576 Var 99 = 1 because 25761 cannot be converted to 2 hexadecimal digits. A0 = "?" CP | CVT | A0 | 5 | 2576 Convert to 4 MCL-Net checksum characters. A0 will contain 64: CP | CVT | A0 | 6 | 64A1 Convert from hexadecimal to integer. A0 will contain 25761 CP | CVT | A0 | 7 | ;; Convert from MCL-Net checksum characters to integer. A0 will contain 00187

7-18