Page 137
Designing Programs
Modem Command In the Insert A Process dialog box, click on Grou MCL-Link Comm. and then click on Command Modem Command. Click on to open the Modem Command dialog box. This dialog box enables you to send a command to modem.
Figure 4-54. Modem Command Dialog Box
Select Command Init.
Enter the initialization command for the modem.
Dial
Enter the telephone number to dial.
Disconnect
Enter the disconnect command.
Auto Answer
Enter the Auto Answer Hayes Command to put the modem in auto answer mode.
Other
Enter any other modem command.
4-71
Page 138
MCL-Designer for Phaser Series User’s Guide
If Error Goto
Selects the action to perform or the screen to go to if an error occurs. Possible errors are: no answer from modem or no connection with the remote site.
Options Check Cradle
Sets the scanner to check for a connection to a cradle.
Toolbar On Bottom Line
Sets a toolbar to appear on the bottom of the screen when reviewing the file. Not supported on Phaser.
!
Click or
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
4-72 to accept the default setting to apply the
Page 139
Designing Programs
Serial Communications Group String Serial Output In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Sting Serial Output. Click on to open the String Serial Output dialog box. This dialog box enables you to select a variable to send through the serial port to a serial output device.
Figure 4-55. String Serial Output Dialog Box Header
Sets the STX or SOH character to the beginning of a variable. STX: Start of Text (02 ASCII). SOH: Start Output Header
Data/Variable to Send
Selects the variable or data to send. Click on the list box to select a variable or enter a value in the list box.
Footer
Sets the ETX, CR or CR/LF character to the end of the variable. ETX (End of Text) - 03 ASCII. CR (Carriage Return) - hard return. LF (Line Feed) - a new line (13 and 10 ASCII).
If Communication Error Goto
Selects the action to perform or screen to go to if an error occurs.
4-73
Page 140
MCL-Designer for Phaser Series User’s Guide
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
Scanner Serial Output In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Scanner Serial Output. Click on to open the Scanner Serial Output dialog box. This dialog box enables you to select a variable to send through the serial port to a scanner output device.
Figure 4-56. Scanner Serial Output Dialog Box
4-74
Page 141
Designing Programs
Add Barcode Descriptor
Sets the default or specific descriptor to be added to the barcode. Click on the list box to select a descriptor or enter a value in the list box.
Data/Variable to Send
Selects the variable or data to send. Click on the list box to select a variable or enter a value in the list box.
Add Key Code
Sets the key code to be sent. Click on the list box to select a code or enter a value in the list box.
If Communication Error Goto
Selects the action to perform or screen to go to if an error occurs.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
Receive Data In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Receive Data. Click on to open the Serial Input dialog box. This dialog box enables you to receive data from the auxiliary port when specific characters are received.
Figure 4-57. Serial Input Dialog Box 4-75
Page 142
MCL-Designer for Phaser Series User’s Guide
Start Character Selects the start character. Click on the appropriate radio button to select the start character. None: Do not wait for start character. STX: Start of Text (02 ASCII). Other: Enter any character in the text box provided. Stop Char.
Selects stop character. Click on the appropriate radio button to select the stop character. Data input will stop when the selecte character is received. ETX: End of Text. CR: Carriage Return. Other: Enter any character in the text box provided. Length: Ends data input when a selected number of character is reached.
to Result Variable Selects the variable that the value is assigned to. Click on open the Variable dialog box to create a new variable or select a existing variable. Refer to Working with Variables on page 4-92 for information on variables. Time Out/ Clear Key
Selects an action to be performed or a screen to go to if the set time interval (seconds) is exceeded.
!
Click or
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
4-76 to accept the default setting to apply the
Page 143
Designing Programs
Print File In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command on to open the Print File. Click Print File dialog box. This dialog box enables you to print a file.
Figure 4-58. Print File Dialog Box Print File File
Selects the file to print.
Replace Variables
Replaces all the variable codes found in file with the actual values of these variables.
If Error Goto
Selects the action to perform or the screen to go to if an error occurs.
Note: Click to go to the Data File Window. For more information, refer to Working With Files on page 4-87 !
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
4-77
Page 144
MCL-Designer for Phaser Series User’s Guide
Others Group Pause In the Insert A Process dialog box, click on Group Other and then click on Command Pause. Click on to open the Pause dialog box. This dialog box enables you to add a pause interval.
Figure 4-59. Pause Dialog Box Seconds
Sets the pause interval. Use the up and down arrow keys to select the pause interval.
ShortCut Delay
Sets the shortcut delay interval. Click on the check box to enable shortcut delay.
!
Click or
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
4-78 to accept the default setting to apply the
Page 145
Designing Programs
Beep In the Insert A Process dialog box, click on Group Other and then click on Comman Beep. Click on to open the Beep dialog box. This dialog box enables you to insert a beep.
Figure 4-60. Beep Dialog Box Beep Type
Selects the type of beep tone to be inserted. Click on the arrow box to select the combination of beeps desired. Click to test the beep option selected.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
4-79
Page 146
MCL-Designer for Phaser Series User’s Guide
Display Data In the Insert A Process dialog box, click on Grou Other and then click on Command Display Data. Click on to open the Display Data dialog box. This dialog box enables you to display data on the scanner.
Figure 4-61. Display Data Dialog Box
4-80
Line
Sets the display data to appear on 1 or 2 lines. Click on the up or down arrow to change the number of lines.
Column
Sets the display data column width (number of characters per line - maximum 20). Click on the up or down arro to change the number of columns.
Video Mode
Sets the text and background colors. Click on the Normal radio button to display the variable in black on a white background or click on the Reverse radio button to display the variable in white on a black background.
Data
Sets the type of data to appear.Click on the arrow box to select the data type.