Page 137

Designing Programs

Modem Command In the Insert A Process dialog box, click on Grou MCL-Link Comm. and then click on Command Modem Command. Click on to open the Modem Command dialog box. This dialog box enables you to send a command to modem.

Figure 4-54. Modem Command Dialog Box

Select Command Init.

Enter the initialization command for the modem.

Dial

Enter the telephone number to dial.

Disconnect

Enter the disconnect command.

Auto Answer

Enter the Auto Answer Hayes Command to put the modem in auto answer mode.

Other

Enter any other modem command.

4-71

Page 138

MCL-Designer for Phaser Series User’s Guide

If Error Goto

Selects the action to perform or the screen to go to if an error occurs. Possible errors are: no answer from modem or no connection with the remote site.

Options Check Cradle

Sets the scanner to check for a connection to a cradle.

Toolbar On Bottom Line

Sets a toolbar to appear on the bottom of the screen when reviewing the file. Not supported on Phaser.

!

Click or

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

4-72 to accept the default setting to apply the

Page 139

Designing Programs

Serial Communications Group String Serial Output In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Sting Serial Output. Click on to open the String Serial Output dialog box. This dialog box enables you to select a variable to send through the serial port to a serial output device.

Figure 4-55. String Serial Output Dialog Box Header

Sets the STX or SOH character to the beginning of a variable. STX: Start of Text (02 ASCII). SOH: Start Output Header

Data/Variable to Send

Selects the variable or data to send. Click on the list box to select a variable or enter a value in the list box.

Footer

Sets the ETX, CR or CR/LF character to the end of the variable. ETX (End of Text) - 03 ASCII. CR (Carriage Return) - hard return. LF (Line Feed) - a new line (13 and 10 ASCII).

If Communication Error Goto

Selects the action to perform or screen to go to if an error occurs.

4-73

Page 140

MCL-Designer for Phaser Series User’s Guide

!

Click or to accept the default setting

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

to apply the

Scanner Serial Output In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Scanner Serial Output. Click on to open the Scanner Serial Output dialog box. This dialog box enables you to select a variable to send through the serial port to a scanner output device.

Figure 4-56. Scanner Serial Output Dialog Box

4-74

Page 141

Designing Programs

Add Barcode Descriptor

Sets the default or specific descriptor to be added to the barcode. Click on the list box to select a descriptor or enter a value in the list box.

Data/Variable to Send

Selects the variable or data to send. Click on the list box to select a variable or enter a value in the list box.

Add Key Code

Sets the key code to be sent. Click on the list box to select a code or enter a value in the list box.

If Communication Error Goto

Selects the action to perform or screen to go to if an error occurs.

!

Click or to accept the default setting

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

to apply the

Receive Data In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command Receive Data. Click on to open the Serial Input dialog box. This dialog box enables you to receive data from the auxiliary port when specific characters are received.

Figure 4-57. Serial Input Dialog Box 4-75

Page 142

MCL-Designer for Phaser Series User’s Guide

Start Character Selects the start character. Click on the appropriate radio button to select the start character. None: Do not wait for start character. STX: Start of Text (02 ASCII). Other: Enter any character in the text box provided. Stop Char.

Selects stop character. Click on the appropriate radio button to select the stop character. Data input will stop when the selecte character is received. ETX: End of Text. CR: Carriage Return. Other: Enter any character in the text box provided. Length: Ends data input when a selected number of character is reached.

to Result Variable Selects the variable that the value is assigned to. Click on open the Variable dialog box to create a new variable or select a existing variable. Refer to Working with Variables on page 4-92 for information on variables. Time Out/ Clear Key

Selects an action to be performed or a screen to go to if the set time interval (seconds) is exceeded.

!

Click or

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

4-76 to accept the default setting to apply the

Page 143

Designing Programs

Print File In the Insert A Process dialog box, click on Group Serial Comm. and then click on Command on to open the Print File. Click Print File dialog box. This dialog box enables you to print a file.

Figure 4-58. Print File Dialog Box Print File File

Selects the file to print.

Replace Variables

Replaces all the variable codes found in file with the actual values of these variables.

If Error Goto

Selects the action to perform or the screen to go to if an error occurs.

Note: Click to go to the Data File Window. For more information, refer to Working With Files on page 4-87 !

Click or to accept the default setting

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

to apply the

4-77

Page 144

MCL-Designer for Phaser Series User’s Guide

Others Group Pause In the Insert A Process dialog box, click on Group Other and then click on Command Pause. Click on to open the Pause dialog box. This dialog box enables you to add a pause interval.

Figure 4-59. Pause Dialog Box Seconds

Sets the pause interval. Use the up and down arrow keys to select the pause interval.

ShortCut Delay

Sets the shortcut delay interval. Click on the check box to enable shortcut delay.

!

Click or

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

4-78 to accept the default setting to apply the

Page 145

Designing Programs

Beep In the Insert A Process dialog box, click on Group Other and then click on Comman Beep. Click on to open the Beep dialog box. This dialog box enables you to insert a beep.

Figure 4-60. Beep Dialog Box Beep Type

Selects the type of beep tone to be inserted. Click on the arrow box to select the combination of beeps desired. Click to test the beep option selected.

!

Click or to accept the default setting

!

Enter the appropriate information to change the values and click changes.

!

Click to close the dialog box without saving the changes.

to apply the

4-79

Page 146

MCL-Designer for Phaser Series User’s Guide

Display Data In the Insert A Process dialog box, click on Grou Other and then click on Command Display Data. Click on to open the Display Data dialog box. This dialog box enables you to display data on the scanner.

Figure 4-61. Display Data Dialog Box

4-80

Line

Sets the display data to appear on 1 or 2 lines. Click on the up or down arrow to change the number of lines.

Column

Sets the display data column width (number of characters per line - maximum 20). Click on the up or down arro to change the number of columns.

Video Mode

Sets the text and background colors. Click on the Normal radio button to display the variable in black on a white background or click on the Reverse radio button to display the variable in white on a black background.

Data

Sets the type of data to appear.Click on the arrow box to select the data type.