Page 77
Designing Programs
Advanced Tab The Advanced tab contains fields that set extra options for the data input.
Figure 4-7. Keyboard Input - Advanced Tab Format Field
Fills the input field with zeroes or blanks on the left or right side. This is used when the input data is smaller than the required input.
Check Range
This option makes it possible to make a selection in the data input. If the input corresponds with the range, it will be read. Otherwise, the input will be ignored.
Check File
This part of the window makes it possible to select that the entered data is or is not in the local data (capture or look up) file. The first field of the file must be the data to check.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
4-11
Page 78
MCL-Designer for Phaser Series User’s Guide
Hot Keys Tab The Hot Keys tab configures some of the keys on the scanner keyboard.
Figure 4-8. Keyboard Input - Hot KeysTab Time Out
Sets a time interval when the scanner will go to another screen or exit if there is no action.
Other Keys
Assigns another function to several keys on the scanner keyboard. These keys include Clear, Up, Down, F+Up, F+Dw and Star (*). When the key is pressed, the selected action occurs.
Function Keys
Assigns another function to the scanner’s function keys. When the key is pressed, the selected action occurs.
!
Click or
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
4-12 to accept the default setting to apply the
Page 79
Designing Programs
Barcode Input Dialog Box The Barcode Input dialog box enables you to insert a barcode variable (enter data from a scanner). There are four tab windows: !
Input Tab
!
Advanced Tab
!
Hot Keys Tab
!
Branch Tab.
InputTab The Input tab (Figure 4-9) enables you to insert a bar code variable (enter the data into a variable using the keyboard).
Figure 4-9. Barcode Input - Input Tab
4-13
Page 80
MCL-Designer for Phaser Series User’s Guide
Input Variable Name
Selects the variable that the input barcode data gets stored into. Click o to open the Variable dialog box to create a new variable or select an existing variable. Refer to Working with Variables on page 4-92 for information on variables.
Select Entry Type(s)
Selects one or more bar code symbologies. TheKeyboar check box allows the operator the opportunity to enter bar code data on the keyboard.
Input Lengt
Sets the length of the bar code input. You can set an interval or a fixed length (minimum=maximum) for the input.
Option Numeric Only
Enter only numeric characters for the barcode variable.
Validation Auto Enter
Sets the program to continue after each scan without having to enter a keystroke.
Enter Key
Sets the program to continue after the operator presses the Enter key
!
Click or
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
4-14 to accept the default setting to apply the
Page 81
Designing Programs
Advanced Tab The Advanced tab sets extra options for the input bar code.
Figure 4-10. Barcode Input - Advanced Tab Check Preamble
Sets a preamble. These preamble characters are compare with the first characters of the input barcode. The data input is rejected if the preamble does not match the data introduction. If the data is not rejected, you can choose to remove these characters.
Fill On Max. Length
Fills the input field with zeroes or blanks on the left or right side. This is used when the input data length is smaller than the required input.
Propose Default Value
Selects a default input value. The default value can be a fixed value or a variable, and can be overwritten at the time of input.
Check File
Selects if the entered data is or is not in the local data file (capture or look up). Note: The first field of the file must be the data to check.
4-15
Page 82
MCL-Designer for Phaser Series User’s Guide
Store Barcode Descriptor
Selects the variable that the barcode descriptor gets stored into. The barcode descriptor is an internal variable which is required to output barcode data to certain host systems (especially RS232 variants and Synapse cables). Click on to open the Variable dialog box to create a new variable or select an existing variable.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
Hot Key Tab The Hot Keys tab configures some of the keys on the scanner keyboard.
Figure 4-11. Barcode Input - Hot Keys Ta
4-16 to apply the
Page 83
Designing Programs
Time Out
Sets a time interval to go to another screen or exit if there is no action.
Other Keys
Assigns another function to several keys on the scanner keyboard. These include Clear, Up, Down, F+Up, F+Dw and Star (*).
Function Keys
Assigns another function to the scanner’s function keys.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
Branch Tab The Branch tab enables the user to set up a case with the bar code type, bar code length or bar code value.
Figure 4-12. Barcode Input - Branch Tab
4-17
Page 84
MCL-Designer for Phaser Series User’s Guide
Enable Test
Enables or disables this test.
IF
Selects a variable or value to test.
Equal
Selects a variable or value to test against the value in theIF list box.
Goto
Selects the action to perform or the screen to go to if the test is true.
Otherwise Goto
Selects the action that occurs if the test is false.
!
Click or to accept the default setting
!
Enter the appropriate information to change the values and click changes.
!
Click to close the dialog box without saving the changes.
to apply the
Note: The values of system variables, in addition to user-defined variables, can be specified using the ampersand ( &”) character plus the name of the system variable to be used. (These system variables are listed in MCL-Code Reference Guid .) For example, system variable 33 (“power source”) indicates whether the scanner is operating off battery power (value=0), in a cradle (value=1), or connected to a host (value=2). This variable can thus be used in a Case-and-Branch to switch automatically between different applications, depending on which of these operating modes the scanner is in.
4-18
Page 85
Designing Programs
Working With Fields Fields are variables, text boxes, or lines that are placed on the screen. The following paragraphs provide information on how to edit these fields.
Placing Fields on a Screen To place fields (display fields or input fields) on the screen: 1. In the Program Designer window, click on one of the buttons listed in Table 4-2. Table 4-2. Field Buttons Placing Display Fields
Placing Input Fields to enter text to enter keyboard input to enter a variable to enter barcode input
2. Set the appropriate settings for that field. 3. Click to accept the information. A cursor, with pages attached, appears on the screen (Figure 4-13).
Figure 4-13. Place a Field on the Screen 4-19
Page 86
MCL-Designer for Phaser Series User’s Guide
4. Position the cursor over a box on the screen. 5. Click the left mouse button to place the field on the screen.
Editing Fields on a Screen To edit a field on the screen: 1. Position the cursor over a field. 2. Double-click on the field. The appropriate dialog box appears. 3. Change or edit the settings. 4. Click to accept the new settings. The field is updated on the screen.
Moving Fields To move a field on the same screen: 1. Position the cursor over a field.
2. Drag the left mouse button. 3. Move the cursor to a new position.
4. Release the mouse button.
4-20