Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 35

P 300STD/FZY/PRO Scanner Product Reference Guide: Chapter 2 Programming the Scanner, pages 57 to 66

Pages 57 to 66 of 325, from P 300STD/FZY/PRO Scanner Product Reference Guide

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol P300

Page 57

Programming the Scanner

Linear Code Type Security Level (Does not apply to Code 128) The P 300 Series scanner offers four levels of decode security for linear code types (e.g. Code 39, Interleaved 2 of 5). Select a higher security level for low quality bar codes. As security levels increase, the scanner’s aggressiveness decreases. Select the security level appropriate for your bar code quality.

Linear Security Level 1 The following code types must be successfully read twice before being transmitted. Code Type

Length

Codabar

All

MSI Plessey

4 or less

D 2 of 5

8 or less

I 2 of 5

8 or less

Linear Security Level 1

Linear Security Level 2 All code types must be successfully read twice before being transmitted.

Linear Security Level 2

2-21

Page 58

P 300STD/FZY/PRO Scanner Product Reference Guide

Linear Security Level 3 Code types other than the following must be successfully read twice before being transmitted. The following codes must be read three times: Code Type

Length

MSI Plessey

4 or less

D 2 of 5

8 or less

I 2 of 5

8 or less

Codabar

8 or less

Linear Security Level 3

Linear Security Level 4 All code types must be successfully read three times before being transmitted

Linear Security Level 4

2-22

Page 59

Programming the Scanner

Bi-directional Redundancy This parameter is only valid when a Linear Code Type Security Level (see page 2-21) is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

Enable Bi-directional Redundancy

Disable Bi-directional Redundancy

2-23

Page 60

P 300STD/FZY/PRO Scanner Product Reference Guide

Autodiscriminate Response Time This parameter extends the length of time during which the scanner tries to detect which host it is connected to on power up. Note: When connected to an LS 5700/5800 scanner, the 5 second option must be used.

1 second

5 seconds

2-24

Page 61

Programming the Scanner

Scan Stand Options Time Delay to Low Power Mode Note: This parameter is available on the P 300PRO only. For extending laser life in scan stand mode, select the time the scanner remains active following a successful decode. Selectable options include 30 seconds, 1 minute, 2 minutes, 3 minutes. To awaken the scanner in low power mode, present a symbol to the scan path. A successful decode restores it to normal blinking.

30 Second Delay

1 Minute Delay

2 Minute Delay

3 Minute Delay

2-25

Page 62

P 300STD/FZY/PRO Scanner Product Reference Guide

Timeout Between Decodes Note: This parameter is available on the P 300PRO only. Timeout Between Decodes, Same Symbol is used in scan stand mode to prevent the beeper from continuously beeping when a symbol is left in the scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended interval is 0.6 seconds. Timeout Between Decodes, Different Symbols is used in scan stand mode to prevent the beeper from beeping when a different symbol appears in the scanner’s field of view before the timeout period between decodes has expired. This is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds. Select the timeouts between decodes for the same or different symbols. 1. Scan the option bar code you wish to set. 2. Scan two bar codes on the next page which correspond to the desired interval, in 0.1 second increments. 3. If you make an error, or wish to change your selection, scan CANCEL.

Timeout Between Decodes The Same Symbol

Timeout Between Decodes Different Symbols

2-26

Page 63

Programming the Scanner

Timeout Between Decodes (Continued)

0

1

2

3

4

5

6

7

8

9

Cancel

2-27

Page 64

P 300STD/FZY/PRO Scanner Product Reference Guide

Enable/Disable UPC-E/UPC-A To enable or disable UPC-E or UPC-A, scan the appropriate bar code below.

Enable UPC-E

Disable UPC-E

Enable UPC-A

Disable UPC-A

2-28

Page 65

Programming the Scanner

Enable/Disable UPC-E1 To enable or disable UPC-E1, scan the appropriate bar code below.

Enable UPC-E1

Disable UPC-E1

2-29

Page 66

P 300STD/FZY/PRO Scanner Product Reference Guide

Enable/Disable EAN-8/EAN-13 To enable or disable EAN-8 or EAN-13, scan the appropriate bar code below.

Enable EAN-8

Disable EAN-8

Enable EAN-13

Disable EAN-13

2-30