Page 37

Chapter 2 Programming the Scanner Introduction The P 300 Series scanner can be programmed to perform various functions, or activate different features. This chapter describes each feature and provides the programming bar codes necessary for selecting these features for your scanner. Before programming, follow the setup instructions in Chapter 1, Getting Started. The P 300 Series scanner is shipped with the default settings shown in Table 2-1. You can change these default values by scanning the appropriate bar codes included in this chapter. These new values replace the standard default values in memory and are preserved even when the scanner is powered down. The default parameter values can be recalled by scanning the Set All Defaults bar code on page 2-9. Even if the default parameters suit your needs, you must still select a terminal type. The scanner automatically identifies the host type on power-up. It makes this determination provided the host is powered-up before the scanner is attached to it. You must then select the appropriate terminal type for that host. The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Several of the bar code parameters apply only to the P300FZY, and others apply only to the P300PRO. This is noted in the parameter menus.

2-1

Page 38

P 300STD/FZY/PRO Scanner Product Reference Guide

Table 2-1. Default Table Parameter

P300FZY Default

P 300PRO Default

Page #

All Defaults

All Defaults

2-9

Host Type

RS-232

RS-232

2-12

Beeper Volume

High

N/A

2-13

Beeper Tone

Medium

High

2-14

Laser On Time

3.0 seconds

5.0 seconds

2-15

Power Mode

Continuous

Continuous

2-16

Trigger Mode

N/A

Level

2-17

Beep After Good Decode

Enable

Enable

2-18

Transmit “No Read” Message

Disable

Disable

2-19

Decode Buffering

N/A

Enable

2-19

LRC Checksum

Disable

Disable

2-20

1

2

2-21

Bi-directional Redundancy

Disable

Disable

2-23

Autodiscriminate Response Time

1.0 second

N/A

2-24

Time Delay to Low Power Mode

N/A

30 seconds

2-25

Time Out Between Same Symbols

N/A

0.6 seconds

2-26

Time Out Between Different Symbols

N/A

0.0 seconds

2-26

Enable

Enable

2-28

Set Default Parameter

Linear Code Type Security Levels

SCAN STAND OPTIONS

UPC/EAN UPC-A

2-2

Page 39

Programming the Scanner

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

UPC-E

Enable

Enable

2-28

UPC-E1

Disable

Disable

2-29

EAN-8

Enable

Enable

2-30

EAN-13

Enable

Enable

2-30

UPC Coupon Code

Disable

N/A

2-31

Bookland EAN

Disable

Disable

2-32

Decode UPC/EAN Supplementals

Ignore

Ignore

2-33

Decode UPC/EAN Supplemental Redundancy

7

7

2-34

Transmit UPC-A Check Digit

Enable

Enable

2-35

Transmit UPC-E Check Digit

Enable

Enable

2-35

UPC-A Preamble

System Character

System Character

2-36

UPC-E Preamble

System Character

System Character

2-37

UPC-E1 Preamble

System Character

System Character

2-38

Convert UPC-E to A

Disable

Disable

2-39

Convert UPC-E1 to UPC-A

Disable

Disable

2-40

Transmit UPC-E1 Check Digit

Enabled

Enable

2-41

0

0

2-42

EAN-8 Zero Extend

Disable

Disable

2-44

Convert EAN-8 to EAN-13 Type

Disable

Disable

2-45

UPC/EAN Security Levels

2-3

Page 40

P 300STD/FZY/PRO Scanner Product Reference Guide

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

Code 128

Enable

Enable

2-46

UCC/EAN-128

Enable

Enable

2-47

ISBT-128

Enable

Enable

2-48

Code 39

Enable

Enable

2-50

Trioptic Code 39

Disable

Disable

2-51

Set Length(s) for Code 39

2 to 55

1-55

2-53

Code 39 Check Digit Verification

Disable

Disable

2-54

Transmit Code 39 Check Digit

Disable

Disable

2-55

Code 39 Full ASCII Conversion

Disable

Disable

2-56

Buffer Code 39

Disable

N/A

2-57

Convert Code 39 to Code 32

Disable

Disable

2-60

Code 32 Prefix

Disable

Enabled

2-61

Code 93

Disable

Disable

2-62

Set Length(s) for Code 93

4-55

4-55

2-63

Enable

Disable

2-65

14

14

2-66

Disable

Disable

2-68

Code 128

Code 39

Code 93

Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5 I 2 of 5 Check Digit Verification

2-4

Page 41

Programming the Scanner

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

Transmit I 2 of 5 Check Digit

Disable

Disable

2-69

Convert I 2 of 5 to EAN 13

Disable

Disable

2-70

Disable

Disable

2-71

12

12

2-72

Codabar

Disable

Disable

2-74

Set Lengths for Codabar

5-55

5-55

2-75

CLSI Editing

Disable

Disable

2-77

NOTIS Editing

Disable

Disable

2-78

Disable

Disable

2-79

Any Length

Any Length

2-81

MSI Plessey Check Digits

One

One

2-82

Transmit MSI Plessey Check Digit

Disable

Disable

2-83

MSI Plessey Check Digit Algorithm

Mod 10/Mod 10

Mod10/Mod10

2-84

Enable/Disable PDF417

N/A

Enable

2-85

Scanning Mode

N/A

Smart Raster

2-89

Raster Height

N/A

15

2-90

Raster Expansion

N/A

11

2-90

Discrete 2 of 5 Discrete 2 of 5 Set Length(s) for D 2 of 5 Codabar

MSI Plessey MSI Plessey Set Length(s) for MSI Plessey

PDF

2-5

Page 42

P 300STD/FZY/PRO Scanner Product Reference Guide

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

N/A

Slab Raster

2-92

Enable/Disable Micro PDF

N/A

Disable

2-86

Code 128 Emulation

N/A

Enable

2-87

UCC/EAN-128 Emulation

N/A

Ignore

2-88

None

None

2-94

0

0

2-95

7013 (<CR/LF> for serial)

Enter

2-96

Data as is

Data As Is

2-97

Standard

Standard

2-12

Baud Rate

9600

9600

2-100

Parity

None

None

2-101

Do Not Check

Check

2-102

Hardware Handshaking

None

None

2-103

Software Handshaking

None

None

2-104

Host Serial Response Time-out

2.0 Sec.

2.0 Sec.

2-106

RTS Line State

Low

Low

2-107

Stop Bit Select

1

1

2-107

Aiming Mode Micro PDF

Data Options Transmit Code ID Character Pause Duration Prefix/Suffix Values

Scan Data Transmission Format RS-232C RS-232 Host Type

Check Parity

2-6

Page 43

Programming the Scanner

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

ASCII Format

8-Bit

8-Bit

2-108

Beep on <BEL>

Disable

Disable

2-108

0

0

2-109

Wand Host Interface

Symbollink

N/A

2-110

Wand Emulator Bar Output

Bar High

N/A

2-111

Variable Leading Margin

80 ms.

N/A

2-112

Convert All to Code 39

Disable

N/A

2-114

IBM PC/AT

N/A

2-115

North American

N/A

2-116

Enabled

N/A

2-118

0

N/A

2-119

Disable

N/A

2-119

MacroPDF Transmit/Decode Mode Symbols

N/A

Buffer all Symbols; Transmit Macro PDF when complete

2-124

Transmit Symbols in Codeword Format

N/A

Disable

2-126

Escape Characters

N/A

None

2-128

Delete Character Set ECIs

N/A

Enable

2-129

Intercharacter Delay Wand Parameters

Keyboard Wedge Parameters Host Type National Keyboard Type Fast Transmit Intercharacter Delay Convert Control Characters MacroPDF Parameters

2-7

Page 44

P 300STD/FZY/PRO Scanner Product Reference Guide

Table 2-1. Default Table (continued) Parameter

P300FZY Default

P 300PRO Default

Page #

ECI Decoder

N/A

Enable

2-130

Transmit Unknown Codewords

N/A

Disable

2-131

Transmit MacroPDF User-Selectable Fields

N/A

Disable

2-132

Flush Macro Buffer

N/A

Disable

2-135

Abort MacroPDF Entry

N/A

Disable

2-135

Transmit File Name

N/A

Disable

2-133

Transmit Block Count

N/A

Disable

2-133

Transmit Time Stamp

N/A

Disable

2-133

Transmit Sender

N/A

Disable

2-133

Transmit Addresses

N/A

Disable

2-134

Transmit File Size

N/A

Disable

2-134

Transmit Checksum

N/A

Disable

2-134

Transmit Macro PDF Control Header

N/A

Disable

2-134

Last Block Marker

N/A

Disable

2-134

Transmit Macro PDF User-Selected Field:

2-8

Page 45

Programming the Scanner

Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 2-1 on page 2-2.

Set All Defaults

2-9

Page 46

P 300STD/FZY/PRO Scanner Product Reference Guide

Host Type RS-232C Host Types Three RS-232C hosts are set up with their own parameter default settings (Table 2-2.) Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 2-2. Terminal-Specific RS-232C Parameter

Standard

ICL

FUJITSU

NIXDORF Mode A/ Mode B

Transmit Code ID

No

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

9600

Parity

None

Even

None

Odd

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

Software Handshaking

None

None

None

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

indefinite

Stop Bit Select

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

*Low = No data to send

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

2-10