Page 37
Chapter 2 Programming the Scanner Introduction The P 300 Series scanner can be programmed to perform various functions, or activate different features. This chapter describes each feature and provides the programming bar codes necessary for selecting these features for your scanner. Before programming, follow the setup instructions in Chapter 1, Getting Started. The P 300 Series scanner is shipped with the default settings shown in Table 2-1. You can change these default values by scanning the appropriate bar codes included in this chapter. These new values replace the standard default values in memory and are preserved even when the scanner is powered down. The default parameter values can be recalled by scanning the Set All Defaults bar code on page 2-9. Even if the default parameters suit your needs, you must still select a terminal type. The scanner automatically identifies the host type on power-up. It makes this determination provided the host is powered-up before the scanner is attached to it. You must then select the appropriate terminal type for that host. The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Several of the bar code parameters apply only to the P300FZY, and others apply only to the P300PRO. This is noted in the parameter menus.
2-1
Page 38
P 300STD/FZY/PRO Scanner Product Reference Guide
Table 2-1. Default Table Parameter
P300FZY Default
P 300PRO Default
Page #
All Defaults
All Defaults
2-9
Host Type
RS-232
RS-232
2-12
Beeper Volume
High
N/A
2-13
Beeper Tone
Medium
High
2-14
Laser On Time
3.0 seconds
5.0 seconds
2-15
Power Mode
Continuous
Continuous
2-16
Trigger Mode
N/A
Level
2-17
Beep After Good Decode
Enable
Enable
2-18
Transmit “No Read” Message
Disable
Disable
2-19
Decode Buffering
N/A
Enable
2-19
LRC Checksum
Disable
Disable
2-20
1
2
2-21
Bi-directional Redundancy
Disable
Disable
2-23
Autodiscriminate Response Time
1.0 second
N/A
2-24
Time Delay to Low Power Mode
N/A
30 seconds
2-25
Time Out Between Same Symbols
N/A
0.6 seconds
2-26
Time Out Between Different Symbols
N/A
0.0 seconds
2-26
Enable
Enable
2-28
Set Default Parameter
Linear Code Type Security Levels
SCAN STAND OPTIONS
UPC/EAN UPC-A
2-2
Page 39
Programming the Scanner
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
UPC-E
Enable
Enable
2-28
UPC-E1
Disable
Disable
2-29
EAN-8
Enable
Enable
2-30
EAN-13
Enable
Enable
2-30
UPC Coupon Code
Disable
N/A
2-31
Bookland EAN
Disable
Disable
2-32
Decode UPC/EAN Supplementals
Ignore
Ignore
2-33
Decode UPC/EAN Supplemental Redundancy
7
7
2-34
Transmit UPC-A Check Digit
Enable
Enable
2-35
Transmit UPC-E Check Digit
Enable
Enable
2-35
UPC-A Preamble
System Character
System Character
2-36
UPC-E Preamble
System Character
System Character
2-37
UPC-E1 Preamble
System Character
System Character
2-38
Convert UPC-E to A
Disable
Disable
2-39
Convert UPC-E1 to UPC-A
Disable
Disable
2-40
Transmit UPC-E1 Check Digit
Enabled
Enable
2-41
0
0
2-42
EAN-8 Zero Extend
Disable
Disable
2-44
Convert EAN-8 to EAN-13 Type
Disable
Disable
2-45
UPC/EAN Security Levels
2-3
Page 40
P 300STD/FZY/PRO Scanner Product Reference Guide
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
Code 128
Enable
Enable
2-46
UCC/EAN-128
Enable
Enable
2-47
ISBT-128
Enable
Enable
2-48
Code 39
Enable
Enable
2-50
Trioptic Code 39
Disable
Disable
2-51
Set Length(s) for Code 39
2 to 55
1-55
2-53
Code 39 Check Digit Verification
Disable
Disable
2-54
Transmit Code 39 Check Digit
Disable
Disable
2-55
Code 39 Full ASCII Conversion
Disable
Disable
2-56
Buffer Code 39
Disable
N/A
2-57
Convert Code 39 to Code 32
Disable
Disable
2-60
Code 32 Prefix
Disable
Enabled
2-61
Code 93
Disable
Disable
2-62
Set Length(s) for Code 93
4-55
4-55
2-63
Enable
Disable
2-65
14
14
2-66
Disable
Disable
2-68
Code 128
Code 39
Code 93
Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5 I 2 of 5 Check Digit Verification
2-4
Page 41
Programming the Scanner
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
Transmit I 2 of 5 Check Digit
Disable
Disable
2-69
Convert I 2 of 5 to EAN 13
Disable
Disable
2-70
Disable
Disable
2-71
12
12
2-72
Codabar
Disable
Disable
2-74
Set Lengths for Codabar
5-55
5-55
2-75
CLSI Editing
Disable
Disable
2-77
NOTIS Editing
Disable
Disable
2-78
Disable
Disable
2-79
Any Length
Any Length
2-81
MSI Plessey Check Digits
One
One
2-82
Transmit MSI Plessey Check Digit
Disable
Disable
2-83
MSI Plessey Check Digit Algorithm
Mod 10/Mod 10
Mod10/Mod10
2-84
Enable/Disable PDF417
N/A
Enable
2-85
Scanning Mode
N/A
Smart Raster
2-89
Raster Height
N/A
15
2-90
Raster Expansion
N/A
11
2-90
Discrete 2 of 5 Discrete 2 of 5 Set Length(s) for D 2 of 5 Codabar
MSI Plessey MSI Plessey Set Length(s) for MSI Plessey
2-5
Page 42
P 300STD/FZY/PRO Scanner Product Reference Guide
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
N/A
Slab Raster
2-92
Enable/Disable Micro PDF
N/A
Disable
2-86
Code 128 Emulation
N/A
Enable
2-87
UCC/EAN-128 Emulation
N/A
Ignore
2-88
None
None
2-94
0
0
2-95
7013 (<CR/LF> for serial)
Enter
2-96
Data as is
Data As Is
2-97
Standard
Standard
2-12
Baud Rate
9600
9600
2-100
Parity
None
None
2-101
Do Not Check
Check
2-102
Hardware Handshaking
None
None
2-103
Software Handshaking
None
None
2-104
Host Serial Response Time-out
2.0 Sec.
2.0 Sec.
2-106
RTS Line State
Low
Low
2-107
Stop Bit Select
1
1
2-107
Aiming Mode Micro PDF
Data Options Transmit Code ID Character Pause Duration Prefix/Suffix Values
Scan Data Transmission Format RS-232C RS-232 Host Type
Check Parity
2-6
Page 43
Programming the Scanner
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
ASCII Format
8-Bit
8-Bit
2-108
Beep on <BEL>
Disable
Disable
2-108
0
0
2-109
Wand Host Interface
Symbollink
N/A
2-110
Wand Emulator Bar Output
Bar High
N/A
2-111
Variable Leading Margin
80 ms.
N/A
2-112
Convert All to Code 39
Disable
N/A
2-114
IBM PC/AT
N/A
2-115
North American
N/A
2-116
Enabled
N/A
2-118
0
N/A
2-119
Disable
N/A
2-119
MacroPDF Transmit/Decode Mode Symbols
N/A
Buffer all Symbols; Transmit Macro PDF when complete
2-124
Transmit Symbols in Codeword Format
N/A
Disable
2-126
Escape Characters
N/A
None
2-128
Delete Character Set ECIs
N/A
Enable
2-129
Intercharacter Delay Wand Parameters
Keyboard Wedge Parameters Host Type National Keyboard Type Fast Transmit Intercharacter Delay Convert Control Characters MacroPDF Parameters
2-7
Page 44
P 300STD/FZY/PRO Scanner Product Reference Guide
Table 2-1. Default Table (continued) Parameter
P300FZY Default
P 300PRO Default
Page #
ECI Decoder
N/A
Enable
2-130
Transmit Unknown Codewords
N/A
Disable
2-131
Transmit MacroPDF User-Selectable Fields
N/A
Disable
2-132
Flush Macro Buffer
N/A
Disable
2-135
Abort MacroPDF Entry
N/A
Disable
2-135
Transmit File Name
N/A
Disable
2-133
Transmit Block Count
N/A
Disable
2-133
Transmit Time Stamp
N/A
Disable
2-133
Transmit Sender
N/A
Disable
2-133
Transmit Addresses
N/A
Disable
2-134
Transmit File Size
N/A
Disable
2-134
Transmit Checksum
N/A
Disable
2-134
Transmit Macro PDF Control Header
N/A
Disable
2-134
Last Block Marker
N/A
Disable
2-134
Transmit Macro PDF User-Selected Field:
2-8
Page 45
Programming the Scanner
Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 2-1 on page 2-2.
Set All Defaults
2-9
Page 46
P 300STD/FZY/PRO Scanner Product Reference Guide
Host Type RS-232C Host Types Three RS-232C hosts are set up with their own parameter default settings (Table 2-2.) Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 2-2. Terminal-Specific RS-232C Parameter
Standard
ICL
FUJITSU
NIXDORF Mode A/ Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Suffix
CR/LF (7013)
CR (1013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
None
Even
None
Odd
Hardware Handshaking
None
RTS/CTS Option 3
None
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
indefinite
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No data to send
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
2-10