Page 19

Chapter 1 Getting Started Introduction A combination of superb performance and ease of use, the rugged, versatile P 300 series of industrial hand-held scanners offers a wide choice of scanners to meet the demands of your data management tasks in extreme environments. Here’s what each member of the P 300 family offers you: !

P 300STD: undecoded version of the scanner.

!

P 300FZY: decodes damaged or poorly printed bar codes; uses multi-interfaces of RS-232, Wand Emulation, Keyboard Wedge, and Synapse.

!

P 300PRO: performs one and two-dimensional bar code scanning; uses multiinterfaces of RS-232 and Synapse.

!

P 300IMG: performs point-and-shoot image capture, outputs to digital formats of TIFF, JPEG, and BMP. This version is covered in the P 300IMG Quick Reference Guide, p/n 72-40804-xx and the P 300IMG Imager Product Reference Guide, p/n 72-40805-xx.

Unpacking Remove the P 300 Series scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page xi. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

1-1

Page 20

P 300STD/FZY/PRO Scanner Product Reference Guide

Accessories Depending on your host system’s configuration, the following items may be included with your scanner. These items are also available through your local Symbol representative or business partner.

Cables !

Power Supply: p/n 50-14001-001

!

DC Power Adapter: p/n 50-16002-009

!

AC Line Cord: (part number is country-specific)

!

Undecoded Cable: p/n 25-38697-01

!

RS-232 Cable: p/n 25-38698-01

!

Keyboard Wedge Cable: 25-38699-01

!

Wand Emulation Cable: 25-39803-01

!

Synapse Cable: 25-38700-01

User Documentation The following user documentation is provided with your scanner: !

P 300 Scanner Quick Reference Guide, p/n 72-39416-xx

!

P 300 Scanner Series Product Reference Guide, p/n 72-39417-xx.

Optional Accessories Optional accessories include various stands, including an Intellistand, and holders, which are supplied at extra cost. Additional units of standard accessories may also be purchased at extra cost.

Setting Up the P 300 Scanner Installing the Cable Insert the cable into the receptacle on the bottom of the scanner, and twist to the right as shown: Note: Do not pull the trigger while installing a cable on the scanner.

1-2

Page 21

Getting Started

Figure 1-1. Installing the Cable

Switching Cables Different cables are required for different hosts. To change the scanner cable: 1. Turn the cable counter-clockwise to unlock. 2. Pull the cable out of the receptacle on the bottom of the scanner. 3. Insert a new cable in the receptacle. Press the cable into the receptacle and twist to the right. Note: Do not pull the trigger while installing a cable on the scanner.

Connecting Power If your host does not provide power to the scanner, you will need to connect external power to the scanner. 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Cable. 2. Connect the DC cable right-angle connector into the power port on the interface cable. Plug the other end of the DC cable into the power supply. 3. Connect the AC line cord into the power supply. Plug the other end into a wall outlet. 1-3

Page 22

P 300STD/FZY/PRO Scanner Product Reference Guide

Connecting to a Host The P 300 series scanners support a variety of host interfaces. The P 300FZY uses RS-232, Synapse, Keyboard Wedge and Wand emulation to interface to a host system. The P 300PRO uses RS-232 and Synapse to interface to a host system. This section describes how to make each of these connections.

RS-232 Connection Both the P 300FZY and P300PRO scanner use RS-232 to interface to a host system. This connection can be made either directly from the scanner to the host, or indirectly through a Synapse adapter cable to the host.

RS-232 Direct Connection 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Cable on page 1-2. 2. Connect the other end of the cable to the serial port on the host.

Figure 1-2. RS-232 Direct Connection 3. Plug one end of the power supply into the power receptacle on the RS-232 cable. Plug the other end into a wall outlet.

Wand Emulation Connection To perform Wand emulation, the scanner can be connected to a portable data terminal, or a controller which collects the data as wand data, and interprets it for the host.

1-4

Page 23

Getting Started

1. Connect the wand emulation interface cable (p/n 25-39803-01) to the bottom of the scanner, as described in Installing the Cable on page 1-2. 2. Connect the other end of the interface cable into the COM port on the PDT or Controller.

Figure 1-3. Wand Emulation Connection 3. Plug one end of the power cable into the power receptacle on the interface cable, and plug the other end into a wall outlet.

Keyboard Wedge Connection When configured for keyboard wedge input, the host accepts input from the scanner as keystrokes. The P 300 can perform keyboard wedge input using a keyboard wedge cable, or via the Synapse cable. To connect the keyboard wedge cable: 1. Connect the keyboard wedge interface cable (p/n 25-38699-01) to the bottom of the scanner, as described in Installing the Cable on page 1-2.

1-5

Page 24

P 300STD/FZY/PRO Scanner Product Reference Guide

2. Connect the male end of the keyboard cable into the female end of the interface cable. Connect the male end of the interface cable into the keyboard port on the host.

Figure 1-4. Keyboard Wedge Connection 3. Plug one end of the power cable into the power receptacle on the interface cable, and plug the other end into a wall outlet.

Synapse Cable Connection Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The Synapse cable has the built-in intelligence to detect the host to which it is connected. 1. Connect the Synapse adapter cable into the bottom of the scanner, as described in Installing the Cable on page 1-2. 2. Plug the other end of the Synapse adapter cable into the Synapse Smart Cable.

Figure 1-5. Synapse Cable Connection 3. Connect the other end of the Synapse smart cable into the host.

1-6

Page 25

Getting Started

RS-232 Connection using Synapse 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Cable on page 1-2. 2. Plug the other end of the interface cable into the Synapse Smart Cable. 3. Connect the other end of the Synapse Smart Cable to the host.

Figure 1-6. RS-232 Connection using Synapse 4. If needed, plug one end of the power supply into the power receptacle on the RS-232 cable. Plug the other end into a wall outlet. 5. If needed, plug one end of the power supply into the power receptacle on the RS-232 cable. Plug the other end into a wall outlet.

Keyboard Wedge Connection using Synapse To connect the Synapse cable with Keyboard Wedge: 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Cable on page 1-2. 2. Connect the other end of the interface cable into the Synapse cable.

1-7

Page 26

P 300STD/FZY/PRO Scanner Product Reference Guide

3. The other end of the Synapse cable has 2 “flying leads”. Connect the male end of the lead into the female end of the keyboard cable. Connect the male end of the lead into the keyboard port on the host.

Figure 1-7. Keyboard Wedge via Synapse Connection

Programming the Scanner Once the connections are made to the host, the scanner must be programmed to work with that host. Refer to Chapter 2, Programming the Scanner for the specific bar code programming information.

P 300PRO Scanning Mode Options The P 300PRO supports several scanning options:

Smart Raster The P 300PRO programmable “Smart Raster” capability causes the scanner to emit a raster pattern dynamically adjusted to the particular PDF417 bar code’s height. To increase scanning efficiency and decrease decode time, the scanner determines the height of the bar code, opening at a size optimal for decoding that bar code. In normal “Smart Raster” operation, a trigger pull causes a slab raster pattern to appear. If the target is a 1-D bar code, the scanner decodes the symbol. If the target bar code is PDF417,

1-8

Page 27

Getting Started the scanning patterns open up to a full, optimized raster pattern as soon as the scanner is properly aligned over the bar code. Aiming “Dot” Pattern

“Slab” Raster Pattern

Y-Axis

Y-Axis

Open Raster Pattern

Horizontal Displacement (X - Axis)

Figure 1-8. P 300PRO Aiming and Scanning Patterns For best operation in Smart Raster mode, keep the scan pattern as parallel to the symbol’s rows as possible, keep the scanner as still as possible, and hold the scanner at an angle which does not give specular reflection. Likewise, the symbol should be in good condition. Unless otherwise programmed, the P 300PRO operates with Smart Raster performance.

Slab Only Raster Scanner activation creates a slab raster pattern which does not open vertically, regardless of bar code type. This may provide optimal performance on small PDF417 and 1D bar codes.

Always Raster When programmed to this option, the scanner directly opens the raster pattern to the programmed height and at the programmed expansion speed when the trigger is pulled.

Programmable Raster The user programs the height of the raster pattern and the rate at which it expands. Scanner activation creates the slab raster pattern which only opens for PDF417 or MicroPDF417 bar

1-9