Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 29 of 35

P 300STD/FZY/PRO Scanner Product Reference Guide, pages 271 to 280

Pages 271 to 280 of 325: Chapter 4 Maintenance and Troubleshooting; Appendix A Programming Reference

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol P300

Page 271

Chapter 4 Maintenance and Troubleshooting Maintenance Cleaning the scanner exit window is the only maintenance required. !

Do not allow any abrasive material to touch the window.

!

Remove any dirt particles with a damp cloth.

!

Wipe the window using a damp cloth, and if necessary, a non-ammonia based detergent.

4-1

Page 272

P 300STD/FZY/PRO Scanner Product Reference Guide

Troubleshooting Table 4-1. Troubleshooting Problem

Possible Cause

Possible Solutions

Nothing happens when you follow the operating instructions.

No power to the scanner.

Symbol is decoded, but not transmitted to the host terminal.

Scanner is not programmed for Be sure the proper host type is selected. the correct host type. (See Chapter 2, Programming the Scanner.)

Scanned data is incorrectly displayed on the terminal.

Scanner is programmed to For a keyboard wedge configuration, work with the wrong keyboard ensure the system is programmed for the type. correct keyboard type, and the CAPS LOCK key is off. RS-232 host setup is wrong. Ensure the scanner’s communication paraneters match the host terminal’s settings. Scanner is programmed to Be sure the proper host is selected. work with the wrong host type. Scanner is programmed with Be sure editing options (e.g., UPC-E to the wrong editing options. UPC-A Conversion) are properly programmed.

Check the system power. Ensure the power supply is connected if your configuration requires a power supply. Scanner is not programmed for Be sure the scanner is programmed for the the correct host. terminal in use. Scanner is not programmed for Be sure the scanner is programmed to read the correct bar code type. the type of bar code you are scanning. Interface/power cables are Check for loose cable connections. loose. Bar code symbol is unreadable. Check the symbol to make sure it is not defaced. Try scanning test symbols of the same bar code type.

Note: If, after performing these checks, the problem is not corrected, contact your distributor or call the Symbol Support Centers. See Service Information on page x for contact information.

4-2

Page 273

Appendix A Programming Reference UCC/EAN-128 UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields. When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character. When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. For example, ]c1 indicates a UCC/EAN-128 symbol with a leading FNC1 character. Standard Code 128 bar codes which do not have a leading FNC 1 may still be used but are not encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN-128 may be mixed in an application. The P 300FZY and P 300PRO scanner autodiscriminates between these symbols, and can enable or disable one or both code types via bar code menus. Table A-1 indicates the behavior of the P 300FZY and P 300PRO in each of the possible parameter settings.

A-1

Page 274

P 300STD/FZY/PRO Scanner Product Reference Guide

Table A-1. Reading Standard Code128 & UCC/EAN 128 Standard Code 128

UCC/EAN128

Effect and Example

Disable

Disable

No Code 128 symbols can be read.

Disable

Enable

Read only symbols with leading FNC 1. Examples: FNC1ABCDFNC1E are read as ABCD 29E AFNC1BCDFNC1E are read as ABCD 29E FNC1FNC1ABCDFNC1E are read as ABCD29E ABCDFNC1E cannot be read ABCDE cannot be read

Enable

Disable

Read only symbols without leading FNC 1. Examples: FNC1ABCDFNC1E cannot be read AFNC1BCDFNC1E cannot be read FNC1FNC1ABCDFNC1E cannot be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE

Enable

Enable

Read both types of symbols. Examples: FNC1ABCDFNC1E are read as ABCD 29E AFNC1BCDFNC1E are read as ABCD 29E FNC1FNC1ABCDFNC1E are read as ABCD29E ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE

A-2

Page 275

Programming Reference

AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character (see Table A-2) m = Modifier Character (see Table A-3)

Table A-2. AIM Code Identifiers Code Identifiers

Code Type

A

Code 39

C

Code 128

E

UPC/EAN

F

Codabar

G

Code 93

H

Code 11

I

Interleaved 2 of 5

L

PDF417

M

MSI Plessey

S

D2 of 5, IATA 2 of 5

X

Code 39 Trioptic

X

Bookland EAN

X

Coupon Code

A-3

Page 276

P 300STD/FZY/PRO Scanner Product Reference Guide

The modifier character is the sum of the applicable option values based on Table A-3. Table A-3. Modifier Characters Code Type Code 39

Option Value

Option

0

No check character or Full ASCII processing.

1

Reader has checked one check character.

3

Reader has checked and stripped check character.

4

Reader has performed Full ASCII character conversion.

5

Reader has performed Full ASCII character conversion and checked one check character.

7

Reader has performed Full ASCII character conversion and checked and stripped check character.

Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4). Trioptic Code 39

0

No option specified at this time. Always transmit 0.

Example: A Trioptic bar code 412356 is transmitted as ]X0412356 Code 128

0

Standard data packet, no Function code 1 in first symbol position.

1

Function code 1 in first symbol character position.

2

Function code 1 in second symbol character position.

Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as ]C1AimId I 2 of 5

0

No check digit processing.

1

Reader has validated check digit.

3

Reader has validated and stripped check digit.

Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123 Codabar

0

No check digit processing.

1

Reader has checked check digit.

3

Reader has stripped check digit before transmission.

Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123

A-4

Page 277

Programming Reference

Table A-3. Modifier Characters (Continued) Code Type

Option Value

Option

Code 93 0

No options specified at this time. Always transmit 0.

Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905 MSI Plessey

0

Single check digit checked.

1

Two check digits checked.

2

Single check digit verified and stripped before transmission.

3

Two check digits verified and stripped before transmission.

Example: An MSI Plessey bar code 4123, with a single check digit checked, is transmitted as ]M04123 D 2 of 5

0 Example:

UPC/EAN

No options specified at this time. Always transmit 0. A D 2 of 5 bar code 4123, is transmitted as ]S04123

0

Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).

1

Two-digit supplement data only.

2

Five-digit supplement data only.

4

EAN-8 data packet.

Example: A UPC-A bar code 012345678905 is transmitted as ]E00012345678905 Bookland EAN

0

No options specified at this time. Always transmit 0.

Example: A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X

A-5

Page 278

P 300STD/FZY/PRO Scanner Product Reference Guide

Prefix / Suffix Values The following values can be assigned as prefixes or suffixes for ASCII character data transmission. If you’re using a keyboard interface, refer to the Synapse “Smart Cable” Interface Guide for keystroke prefix/suffix values. Table A-4. Prefix/Suffix Values Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character 1000 %U NUL 1001 $A SOH 1002 $B STX 1003 $C ETX 1004 $D EOT 1005 $E ENQ 1006 $F ACK 1007 $G BELL 1008 $H BCKSPC 1009 $I HORIZ TAB 1010 $J LF/NW LN 1011 $K VT 1012 $L FF 1013 $M CR/ENTER 1014 $N SO 1015 $O SI 1016 $P DLE 1017 $Q DC1 1018 $R DC2 1019 $S DC3 1020 $T DC4 1021 $U NAK 1022 $V SYN 1023 $W ETB 1024 $X CAN 1025 $Y EM 1026 $Z SUB 1027 %A ESC 1028 %B FS 1029 %C GS

A-6

Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character 1030 %D RS 1031 %E US 1032 Space Space 1033 /A ! 1034 /B " 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 1046 . . 1047 / / 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1057 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ;

Page 279

Programming Reference

Table A-3. Prefix/Suffix Values (continued) Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^

Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character 1095 %O _ 1096 %W ` 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1127 Undefined 7013

ENTER

A-7

Page 280

P 300STD/FZY/PRO Scanner Product Reference Guide

A-8