The text of a manual · part 21 of 35
P 300STD/FZY/PRO Scanner Product Reference Guide: Chapter 3 Advanced Data Formatting (ADF), pages 193 to 202
Pages 193 to 202 of 325, from P 300STD/FZY/PRO Scanner Product Reference Guide
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P300
Page 193
Advanced Data Formatting (ADF)
Code Lengths (continued)
<FN3>6C13719
<FN3>6C1371A
25
26
<FN3>6C1371B
<FN3>6C1371C
27
28
<FN3>6C1371D
<FN3>6C1371E
29
30
3-21
Page 194
P 300 STD/FZY/PRO Scanner Product Reference Guide
Message Containing A Specific Data String Select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string.
Specific String at Start To apply formatting to data that begins with a specific character or data string: 1. Scan the bar code below. 2. Enter a string representing the desired character or characters (up to a total of 8) using the Alphanumeric Keyboard beginning on page 3-84. 3. Scan End Of Message on page 3-93.
<FN3>6C201 Specific String At Start
Specific String, Any Location To apply formatting to data that contains a specific character or data string: 1. Scan the bar code below. 2. Scan a two-digit number representing the position (include a leading “zero” if necessary) using the Numeric Keypad on page 3-23. 3. Enter the desired character or characters (up to a total of 8) using the Alphanumeric Keyboard beginning on page 3-84. 4. Scan End Of Message on page 3-93.
<FN3>6C200 Specific String Any Location
Any Message OK By not scanning any bar code, all selected code types are formatted, regardless of information contained.
3-22
Page 195
Advanced Data Formatting (ADF)
Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard.
<FN3>A0 0
<FN3>A1 1
<FN3>A2 2
<FN3>A3 3
<FN3>A4 4
<FN3>A5 5
<FN3>A6 6
<FN3>A7 7
<FN3>A8 8
<FN3>A9 9
<FN3>ACancel
3-23
Page 196
P 300 STD/FZY/PRO Scanner Product Reference Guide
Rule Belongs To Set Scan a bar code below to select which set a rule belongs to.
<FN3>6C12A1
<FN3>6C12A2
Rule Belongs To Set 1
Rule Belongs To Set 2
<FN3>6C12A3
<FN3>6C12A4
Rule Belongs To Set 3
Rule Belongs To Set 4
3-24
Page 197
Advanced Data Formatting (ADF)
Actions Select how to format the data meeting the defined criteria before transmission.
Send Data Use the following bar codes to send all data that remains, send all data up to a specific character selected from the Alphanumeric Keyboard on page 3-84, or send the next N characters. N = any number from 1 to 254, selected from the Alphanumeric Keyboard on page 3-84.
<FN3>6A5211 Send Data Up To Character
<FN3>6A110
<FN3>6A141001
Send All Data That Remains
Send Next Character
<FN3>6A141002
<FN3>6A141003
Send Next 2 Characters
Send Next 3 Characters
3-25
Page 198
P 300 STD/FZY/PRO Scanner Product Reference Guide
Send Data (continued)
<FN3>6A141004
<FN3>6A141005
Send Next 4 Characters
Send Next 5 Characters
<FN3>6A141006
<FN3>6A141007
Send Next 6 Characters
Send Next 7 Characters
<FN3>6A141008
<FN3>6A141009
Send Next 8 Characters
Send Next 9 Characters
<FN3>6A14100A
<FN3>6A14100B
Send Next 10 Characters
Send Next 11 Characters
3-26
Page 199
Advanced Data Formatting (ADF)
Send Data (continued)
<FN3>6A14100C
<FN3>6A14100D
Send Next 12 Characters
Send Next 13 Characters
<FN3>6A14100E
<FN3>6A14100F
Send Next 14 Characters
Send Next 15 Characters
<FN3>6A141010
<FN3>6A141011
Send Next 16 Characters
Send Next 17 Characters
3-27
Page 200
P 300 STD/FZY/PRO Scanner Product Reference Guide
Send Data (continued)
<FN3>6A141012
<FN3>6A141013
Send Next 18 Characters
Send Next 19 Characters
<FN3>6A141014
<FN3>6A141032
Send Next 20 Characters
Send Next 50 Characters
<FN3>6A141064
<FN3>6A141096
Send Next 100 Characters
Send Next 150 Characters
3-28
<FN3>6A1410C8
<FN3>6A1410FA
Send Next 200 Characters
Send Next 250 Characters
Page 201
Advanced Data Formatting (ADF)
Send Pause
Send Pause
Setup Field(s) Use the following bar codes to move the cursor in relation to a specified character. Note: If there is no match when the rule is interpreted and the rule fails, the next rule is checked.
Move Cursor To a Character Scan the Move Cursor To Character bar code, then any printable ASCII character from the Alphanumeric Keyboard on page 3-84. This moves the cursor to the position after the matching character. If the character is not there, the rule fails and ADF tries the next rule.
<FN3>6A5230 Move Cursor To Character
Move Cursor to Start of Data Scan this bar code to move cursor to the beginning of the data.
<FN3>6A1231 Move Cursor To Start
3-29
Page 202
P 300 STD/FZY/PRO Scanner Product Reference Guide
Move Cursor Past a Character This parameter moves the cursor past all sequential occurrences of a selected character. Scan the Move Cursor Past Character bar code on page 3-30, then select a character from the Alphanumeric Keyboard on page 3-84. If the character is not there, the cursor does not move (i.e., has no effect).
<FN3>6A5235 Move Cursor Past Character
Skip Ahead “N” Characters Scan one of these bar codes to select the number of positions ahead you wish to move the cursor.
<FN3>6A143301
<FN3>6A143302
Skip Ahead 1 Character
Skip Ahead 2 Characters
<FN3>6A143303
<FN3>6A143304
Skip Ahead 3 Characters
Skip Ahead 4 Characters
3-30