Page 107

Programming the Scanner

Enable/Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5, scan the appropriate bar code below.

Enable Discrete 2 of 5

Disable Discrete 2 of 5

2-71

Page 108

P 300STD/FZY/PRO Scanner Product Reference Guide

Set Lengths for Discrete 2 of 5 Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select D 2 of 5 One Discrete Length, then scan 1, 4, the only D 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

D 2 of 5 - One Discrete Length

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only D 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

D 2 of 5 - Two Discrete Lengths

2-72

Page 109

Programming the Scanner

Length Within Range - This option allows you to decode a code type within a specified range. For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

D 2 of 5 - Length within Range

Any Length - Scanning this option allows you to decode D 2 of 5 symbols containing any number of characters. Note: Selecting this option may lead to misdecodes for D 2 of 5 codes.

D 2 of 5 - Any Length

2-73

Page 110

P 300STD/FZY/PRO Scanner Product Reference Guide

Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below.

Enable Codabar

Disable Codabar

2-74

Page 111

Programming the Scanner

Set Lengths for Codabar Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. It also includes any start or stop characters. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Codabar One Discrete Length, then scan 1, 4, the only Codabar symbols decoded are those containing 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

Codabar - One Discrete Length

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, the only Codabar symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

Codabar - Two Discrete Lengths

Length Within Range - This option allows you to decode a code type within a specified range. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

Codabar - Length within Range

2-75

Page 112

P 300STD/FZY/PRO Scanner Product Reference Guide

Any Length - Scanning this option allows you to decode Codabar symbols containing any number of characters.

Codabar - Any Length

2-76

Page 113

Programming the Scanner

CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters.

Enable CLSI Editing

Disable CLSI Editing

2-77

Page 114

P 300STD/FZY/PRO Scanner Product Reference Guide

NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.

Enable NOTIS Editing

Disable NOTIS Editing

2-78

Page 115

Programming the Scanner

Enable/Disable MSI Plessey To enable or disable MSI Plessey, scan the appropriate bar code below.

Enable MSI Plessey

Disable MSI Plessey

2-79

Page 116

P 300STD/FZY/PRO Scanner Product Reference Guide

Set Lengths for MSI Plessey Lengths for MSI Plessey may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select MSI Plessey One Discrete Length, then scan 1, 4, the only MSI Plessey symbols decoded are those containing 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

MSI Plessey - One Discrete Length

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select MSI Plessey Two Discrete Lengths, then scan 0, 2, 1, 4, the only MSI Plessey symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

MSI Plessey - Two Discrete Lengths

2-80