Page 47
Chapter 4 MS-904HS Specifications Overview This chapter provides the technical specifications for the MS-904HS (High Performance) scanners.
4-1
Page 48
MS-804FZY and MS-904HS Integration Guide
MS-904HS Electrical Interface
Figure 4-1. MiniScan Connector Table 4-1 lists the pin functions of the MS-904HS interface.
Table 4-1. MS-904HS Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
4
Not used
5
Ground
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50 mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
4-2
O = Output
Power supply ground input and signal ground reference.
Page 49
MS-904HS Specifications
MS-904HS Technical Specifications Table 4-2. MS-904HS Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Idle Current Standby Current Vcc Noise Level
5.0 VDC ±10% 130 mA ±30 mA typical 70 mA ±10 mA typical 20 mA ±5 mA typical 100 mV peak-to-peak max.
Scan Rate
186 (±13) scans/sec (bidirectional)
Laser Power
0.8 mW ±0.1 mW, λ = 650 nm nominal
Print Contrast (minimum)
25% absolute dark/light reflectance measured at 650 nm
Scan Angle
37° (typical)
Skew Tolerance
± 45° from normal (see Figure 4-2 on page 4-5)
Pitch Angle
± 60° from normal (see Figure 4-2 on page 4-5)
Roll
± 30° from vertical (see Figure 4-2 on page 4-5)
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
Multiple 30” drops
Vibration
Withstands a sinusoidal vibration of 4 G along each of the mutually perpendictular axes for a period of 1 hr per axis over a frequency range of 20Hz to 1600 Hz.
ESD
± 15kV air discharge ± 8kV indirect discharge
Laser Class
CDRH Class II, IEC Class 2
Operating Temperature
32° to 104°F (0° to 40°C)
Storage Temperature
-40° to 140°F (-40° to 60°C)
Humidity
5% to 95% non-condensing
Note: Environmental and/or Tolerance Parameters are not cumulative.
4-3
Page 50
MS-804FZY and MS-904HS Integration Guide
Table 4-2. MS-904HS Technical Specifications @ 23°C (Continued) Item
Description
Height
1.02 in. (2.59 cm) maximum
Width
1.93 in. (4.90 cm) maximum
Depth
2.31 in. (5.87 cm) maximum
Weight
1.70 oz. (48.20 g)
Note: Environmental and/or Tolerance Parameters are not cumulative.
4-4
Page 51
MS-904HS Specifications
Skew
Pitch
+ 60° from normal
Pitch Angle
+ 65° from normal
Skew Angle
20 mil Symbol
20 mil Symbo l
Scan Beam
8.0
8.0 in. ( in. (
203
203
.2 m
.2 m m)
m)
Scan Beam
Roll Roll Angle
+ 30° from normal mil 20 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
8.0 in. ( 203 .2 mm )
Scan Beam
Figure 4-2. MS-904HS Skew, Pitch and Roll 4-5
Page 52
MS-804FZY and MS-904HS Integration Guide
MS-904HS Decode Zone The figures shown are typical values. Table 4-3 on page 4-7 lists the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating The Usable Scan Length Method on page 2-10.
Note: Typical performance at 73.4˚F (23˚C) on high quality symbols.
MS 904HS in.
cm
8
20.3
6
15.2
4
10.2
2
5.1
0
0
2
5.1
4
10.2
6
15.2
8
20.3
5 mil 1.0 1.0
3.5 7.5 mil
6.0
10 mil
0.5 1.0
7.5 100% UPC
10.5 20 mil 16.0 40 mil
*
21.0 55 mil 23.0 in. 0 cm 0
5 12.7
10 25.4
15 38.1
20 50.8
Depth of Field *Minimum distance determined by symbol length and scan angle
Figure 4-3. MS-904HS Decode Zone (Typical)
4-6
W i d t h o f F i e l d
Page 53
MS-904HS Specifications
Table 4-3. MS-904HS Decode Distances Symbol Density/ Symbol p/n / Bar Code Type/ W-N Ratio
Bar Code Content/ Contrast1
Typical Working Ranges
Guaranteed Working Ranges
Near
Far
Near
Far
5 mil 64-17453-01 Code 39; 1:2.5
ABCDEFGH 90% MRD
1.0 in. 2.54 cm
3.5 in. 8.89 cm
1.5 in. 3.81 cm
2.5 in. 6.35 cm
7.5 mil 64-17452-01 Code 39; 1:2.5
ABCDEF 90% MRD
1.0 in. 2.54 cm
6.0 in. 15.24 cm
1.5 in. 3.81 cm
5.0 in. 12.7 cm
10 mil Code 39; 1:2.2
FGH 90% MRD Note 4
0.5 in. 1.27 cm
7.5 in. 19.05 cm
1.1 in. 2.79 cm
6.0 in. 15.24 cm
13 mil 64-05303-01 100% UPC
12345678905 90% MRD
1.0 in. 2.54 cm
10.5 in. 26.67 cm
1.5 in. 3.81 cm
9.0 in. 22.86 cm
20 mil 60-01429-01 Code 39; 1:2.2
123 90% MRD Note 4
Note 2
16.0 in. 40.64 cm
Note 2
14.0 in. 35.56 cm
40 mil 64-17457-01 Code 39; 1:2.2
AB 90% MRD Note 4
Note 2
21.0 in. 53.34 cm
Note 2
16.5 in. 41.91 cm
55 mil 64-17458-01 Code 39; 1:3
CD 90% MRD Note 4
Note 2
23.0 in. 58.42 cm
Note 2
17.5 in. 44.45 cm
Notes: 1. CONTRAST measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities (not specified) largely depend on the width of the bar code and the scan angle. 3. Working range specifications at ambient temperature (23°C), pitch=15°, roll=0°, skew=0°, photographic quality, ambient light<200 ft-c. 4. The MS-904HS does not decode 1 to 4 digit Code 39 bar codes by default. To test this specification, enable Code 39 Length 2 bar codes (see Set Lengths for Code 39 on page 7-53).
4-7
Page 54
MS-804FZY and MS-904HS Integration Guide
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system. Calculating The Usable Scan Length Method on page 2-10 describes how to calculate the usable scan length. The scan angle is provided in Table 4-3.
4-8