Page 99

Parameter Menus

Convert UPC-E to UPC-A Parameter # 25h This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Scan DO NOT CONVERT UPC-E TO UPC-A to transmit UPC-E (zero suppressed) decoded data.

Convert UPC-E To UPC-A (Enable) (01h)

*Do Not Convert UPC-E To UPC-A (Disable) (00h)

7-39

Page 100

MS-804FZY and MS-904HS Integration Guide

Convert UPC-E1 to UPC-A Parameter # 26h Enable this parameter to convert UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Scan DO NOT CONVERT UPC-E TO UPC-A to transmit UPC-E1 (zero suppressed) decoded data.

Convert UPC-E1 To UPC-A (Enable) (01h)

*Do Not Convert UPC-E1 To UPC-A (Disable) (00h)

7-40

Page 101

Parameter Menus

EAN Zero Extend Parameter # 27h When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this parameter to transmit EAN-8 symbols as is.

Enable EAN Zero Extend (01h)

*Disable EAN Zero Extend (00h)

7-41

Page 102

MS-804FZY and MS-904HS Integration Guide

UPC/EAN Security Level Parameter # 4Dh The MS-804FZY and MS-904HS offer four levels of decode security for UPC/EAN bar codes. Select higher levels of security for decreasing levels of bar code quality. Increasing security decreases the scanner’s aggressiveness, so choose only that level of security necessary for the application.

UPC/EAN Security Level 0 This default setting allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

*UPC/EAN Security Level 0 (00h)

UPC/EAN Security Level 1 Select this option if misdecodes occur. This security level eliminates most misdecodes.

UPC/EAN Security Level 1 (01h)

7-42

Page 103

Parameter Menus

UPC/EAN Security Level 2 Select this option if Security level 1 fails to eliminate misdecodes.

UPC/EAN Security Level 2 (02h)

UPC/EAN Security Level 3 If misdecodes still occur after selecting Security Level 2, select this security level. Be advised, selecting this option is an extreme measure against misdecoding severely out of spec bar codes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, try to improve the quality of the bar codes.

UPC/EAN Security Level 3 (03h)

7-43

Page 104

MS-804FZY and MS-904HS Integration Guide

Linear UPC/EAN Decode Parameter # 44h This option applies to code types containing two adjacent blocks (e.g., UPC-A, EAN-8, EAN-13). When enabled, a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. Enable this option when bar codes are in proximity to each other.

Enable Linear UPC/EAN Decode (01h)

*Disable Linear UPC/EAN Decode (00h)

7-44

Page 105

Parameter Menus

UPC Half Block Stitching Parameter # 4Ah This parameter enables UPC Half Block Stitching.

Enable UPC Half Block Stitching (01h)

*Disable UPC Half Block Stitching (00h)

7-45

Page 106

MS-804FZY and MS-904HS Integration Guide

Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below.

*Enable Code 128 (01h)

Disable Code 128 (00h)

7-46

Page 107

Parameter Menus

Enable/Disable UCC/EAN-128 Parameter # 0Eh To enable or disable UCC/EAN-128, scan the appropriate bar code below.

*Enable UCC/EAN-128 (01h)

Disable UCC/EAN-128 (00h)

7-47

Page 108

MS-804FZY and MS-904HS Integration Guide

Enable/Disable ISBT 128 Parameter # 54h To enable or disable ISBT 128, scan the appropriate bar code below.

Enable ISBT 128 (01h)

*Disable ISBT 128 (00h)

Lengths for Code 128 No length setting is required for Code 128.

7-48