Symbol MS4404/MS4407 Integration Guide: Symbologies, pages 159 to 168

Pages 159 to 168 of 310, from Symbol MS4404/MS4407 Integration Guide

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-4407

Page 159

Chapter 11 Symbologies Overview This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. The imager is shipped with the settings shown in the Symbology Default Table on page 11-2 (also see Appendix A, Standard Defaults for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value:

• Capture the appropriate bar codes in this guide. These new values replace the standard default values in memory.

• For SSI and USB SNAPI hosts, send a “parameter send” command from the host system. Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer Guide for detailed instructions for changing parameter values using this method. NOTE

Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.

To return all features to default values, capture *Set All Defaults on page 6-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*Enable UPC-A (00h)

Feature/Option

Page 160

11 - 2 Symbol MS4404/MS4407 Integration Guide

Imaging Sequence Examples In most cases, capturing one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply capture the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 11-14. The imager issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require capturing several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.

Errors While Imaging Unless otherwise specified, to correct an error during an imaging sequence, just re-capture the correct parameter.

Symbology Parameter Defaults Table 11-1 lists the defaults for all symbologies parameters. To change any option, capture the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 11-7. NOTE

See Appendix A, Standard Defaults for all user preferences, hosts, and miscellaneous default parameters.

Table 11-1 Symbology Default Table

Parameter

Parameter Number

Default

Page Number

UPC/EAN UPC-A

01h

Enable

11-7

UPC-E

02h

Enable

11-7

UPC-E1

0Ch

Disable

11-8

EAN-8/JAN 8

04h

Enable

11-8

EAN-13/JAN 13

03h

Enable

11-9

Bookland EAN

53h

Disable

11-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

11-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

F1h 43h F1h 44h

11-13

UPC/EAN/JAN Supplemental Redundancy

50h

10

11-14

Transmit UPC-A Check Digit

28h

Enable

11-14

Transmit UPC-E Check Digit

29h

Enable

11-15

Page 161

Symbologies 11 - 3

Table 11-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Transmit UPC-E1 Check Digit

2Ah

Enable

11-15

UPC-A Preamble

22h

System Character

11-16

UPC-E Preamble

23h

System Character

11-17

UPC-E1 Preamble

24h

System Character

11-18

Convert UPC-E to A

25h

Disable

11-19

Convert UPC-E1 to A

26h

Disable

11-19

EAN-8/JAN-8 Extend

27h

Disable

11-20

Bookland ISBN Format

F1h 40h

ISBN-10

11-21

UCC Coupon Extended Code

55h

Disable

11-22

Code 128

08h

Enable

11-22

UCC/EAN-128

0Eh

Enable

11-23

ISBT 128

54h

Enable

11-24

Code 39

00h

Enable

11-25

Trioptic Code 39

0Dh

Disable

11-25

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

11-26

Code 32 Prefix

E7h

Disable

11-26

Set Length(s) for Code 39

12h 13h

2 to 55

11-27

Code 39 Check Digit Verification

30h

Disable

11-29

Transmit Code 39 Check Digit

2Bh

Disable

11-29

Code 39 Full ASCII Conversion

11h

Disable

11-30

Buffer Code 39

71h

Disable

11-31

Code 93

09h

Disable

11-34

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

11-34

Code 11

0Ah

Disable

11-36

Set Lengths for Code 11

1Ch 1Dh

4 to 55

11-36

Code 128

Code 39

Code 93

Code 11

Page 162

11 - 4 Symbol MS4404/MS4407 Integration Guide

Table 11-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Code 11 Check Digit Verification

34h

Disable

11-38

Transmit Code 11 Check Digit(s)

2Fh

Disable

11-39

Interleaved 2 of 5 (ITF)

06h

Enable

11-39

Set Lengths for I 2 of 5

16h 17h

14

11-40

I 2 of 5 Check Digit Verification

31h

Disable

11-42

Transmit I 2 of 5 Check Digit

2Ch

Disable

11-42

Convert I 2 of 5 to EAN 13

52h

Disable

11-43

Discrete 2 of 5

05h

Disable

11-43

Set Length(s) for D 2 of 5

14h 15h

12

11-44

Codabar

07h

Disable

11-46

Set Lengths for Codabar

18h 19h

5 to 55

11-46

CLSI Editing

36h

Disable

11-48

NOTIS Editing

37h

Disable

11-48

MSI

0Bh

Disable

11-49

Set Length(s) for MSI

1Eh 1Fh

4 to 55

11-50

MSI Check Digits

32h

One

11-52

Transmit MSI Check Digit

2Eh

Disable

11-52

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

11-53

Inverse 1D

F1h 4Ah

Regular

11-54

US Postnet

59h

Enable

11-55

US Planet

5Ah

Enable

11-55

UK Postal

5Bh

Enable

11-56

Transmit UK Postal Check Digit

60h

Enable

11-56

Japan Postal

F0h 22h

Enable

11-57

Australian Postal

F0h 23h

Enable

11-57

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Postal Codes

Page 163

Symbologies 11 - 5

Table 11-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Dutch Postal

F0h 46h

Enable

11-58

4State Postal

F1h 50h

Disable

11-58

Transmit US Postal Check Digit

5Fh

Enable

11-59

GS1 DataBar (Formerly RSS, Reduced Space Symbology) GS1 DataBar-14

F0h 52h

Enable

11-60

GS1 DataBar Limited

F0h 53h

Enable

11-60

GS1 DataBar Expanded

F0h 54h

Enable

11-61

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

11-61

Composite CC-C

F0h 55h

Disable

11-62

Composite CC-A/B

F0h 56h

Disable

11-62

Composite TLC-39

F0h 73h

Disable

11-63

UPC Composite Mode

F0h 58h

Always Linked

11-63

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

11-64

UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes

F0h ABh

Disable

11-65

PDF417

0Fh

Enable

11-66

MicroPDF417

E3h

Disable

11-66

Code 128 Emulation

7Bh

Disable

11-67

Data Matrix

F0h 24h

Enable

11-68

Data Matrix Inverse

F1h 4Ch

Regular

11-68

Maxicode

F0h 26h

Enable

11-69

QR Code

F0h 25h

Enable

11-70

MicroQR

F1h 3Dh

Enable

11-70

QR Inverse

F1h 4Bh

Regular

11-71

Aztec

F1h 3Eh

Enable

11-71

Aztec Inverse

F1h 4Dh

Regular

11-72

Composite

2-D Symbologies

Page 164

11 - 6 Symbol MS4404/MS4407 Integration Guide

Table 11-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Symbology-Specific Security Levels Redundancy Level

4Eh

1

11-73

Security Level

4Dh

1

11-75

Intercharacter Gap Size

F0h 7Dh

Normal

11-76

Report Version

11-76

Macro PDF Macro PDF Transmit/Decode Mode Symbols

BCh

Passthrough Mode

11-78

Transmit Macro PDF Control Header

B8h

Disable

11-79

Escape Characters

E9h

None

11-79

Flush Macro PDF Buffer

11-80

Abort Macro PDF Entry

11-80

Page 165

Symbologies 11 - 7

UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, capture the appropriate bar code below.

*Enable UPC-A (01h)

Disable UPC-A (00h)

Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, capture the appropriate bar code below.

*Enable UPC-E (01h)

Disable UPC-E (00h)

Page 166

11 - 8 Symbol MS4404/MS4407 Integration Guide

Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, capture the appropriate bar code below. NOTE

UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1 (01h)

*Disable UPC-E1 (00h)

Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, capture the appropriate bar code below.

*Enable EAN-8/JAN-8 (01h)

Disable EAN-8/JAN-8 (00h)

Page 167

Symbologies 11 - 9

Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, capture the appropriate bar code below.

*Enable EAN-13/JAN-13 (01h)

Disable EAN-13/JAN-13 (00h)

Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, capture the appropriate bar code below.

Enable Bookland EAN (01h)

*Disable Bookland EAN (00h)

NOTE

If you enable Bookland EAN, select a Bookland ISBN Format on page 11-21. Also select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 11-10..

Page 168

11 - 10 Symbol MS4404/MS4407 Integration Guide

Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available:

• If you select Ignore UPC/EAN with Supplementals, and the scanner is presented with a UPC/EAN plus supplemental symbol, the scanner decodes UPC/EAN and ignores the supplemental characters.

• If you select Decode UPC/EAN with Supplementals, the scanner only decodes UPC/EAN symbols with supplemental characters, and ignores symbols without supplementals.

• If you select Autodiscriminate UPC/EAN Supplementals, the scanner decodes UPC/EAN symbols with supplemental characters immediately. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 11-14 before transmitting its data to confirm that there is no supplemental.

• If you select one of the following Supplemental Mode options, the scanner immediately transmits EAN-13 bar codes starting with that prefix that have supplemental characters. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 11-14 before transmitting its data to confirm that there is no supplemental. The scanner transmits UPC/EAN bar codes that do not have that prefix immediately. • Enable 378/379 Supplemental Mode • Enable 978/979 Supplemental Mode NOTE

If you select 978/979 Supplemental Mode and are scanning Bookland EAN bar codes, see Enable/Disable Bookland EAN on page 11-9 to enable Bookland EAN, and select a format using Bookland ISBN Format on page 11-21.

• Enable 977 Supplemental Mode • Enable 414/419/434/439 Supplemental Mode • Enable 491 Supplemental Mode • Enable Smart Supplemental Mode - applies to EAN-13 bar codes starting with any prefix listed previously. • Supplemental User-Programmable Type 1 - applies to EAN-13 bar codes starting with a 3-digit user-defined prefix. Set this 3-digit prefix using User-Programmable Supplementals on page 11-13. • Supplemental User-Programmable Type 1 and 2 - applies to EAN-13 bar codes starting with either of two 3-digit user-defined prefixes. Set the 3-digit prefixes using User-Programmable Supplementals on page 11-13. • Smart Supplemental Plus User-Programmable 1 - applies to EAN-13 bar codes starting with any prefix listed previously or the user-defined prefix set using User-Programmable Supplementals on page 11-13. • Smart Supplemental Plus User-Programmable 1 and 2 - applies to EAN-13 bar codes starting with any prefix listed previously or one of the two user-defined prefixes set using User-Programmable Supplementals on page 11-13. NOTE

To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters.