The text of a manual · part 23 of 39
Symbol MS4404/MS4407 Integration Guide: Symbologies, pages 159 to 168
Pages 159 to 168 of 310, from Symbol MS4404/MS4407 Integration Guide
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-4407
Page 159
Chapter 11 Symbologies Overview This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. The imager is shipped with the settings shown in the Symbology Default Table on page 11-2 (also see Appendix A, Standard Defaults for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value:
• Capture the appropriate bar codes in this guide. These new values replace the standard default values in memory.
• For SSI and USB SNAPI hosts, send a “parameter send” command from the host system. Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer Guide for detailed instructions for changing parameter values using this method. NOTE
Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
To return all features to default values, capture *Set All Defaults on page 6-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*Enable UPC-A (00h)
Feature/Option
Page 160
11 - 2 Symbol MS4404/MS4407 Integration Guide
Imaging Sequence Examples In most cases, capturing one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply capture the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 11-14. The imager issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require capturing several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Imaging Unless otherwise specified, to correct an error during an imaging sequence, just re-capture the correct parameter.
Symbology Parameter Defaults Table 11-1 lists the defaults for all symbologies parameters. To change any option, capture the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 11-7. NOTE
See Appendix A, Standard Defaults for all user preferences, hosts, and miscellaneous default parameters.
Table 11-1 Symbology Default Table
Parameter
Parameter Number
Default
Page Number
UPC/EAN UPC-A
01h
Enable
11-7
UPC-E
02h
Enable
11-7
UPC-E1
0Ch
Disable
11-8
EAN-8/JAN 8
04h
Enable
11-8
EAN-13/JAN 13
03h
Enable
11-9
Bookland EAN
53h
Disable
11-9
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
11-10
User-Programmable Supplementals Supplemental 1: Supplemental 2:
F1h 43h F1h 44h
11-13
UPC/EAN/JAN Supplemental Redundancy
50h
10
11-14
Transmit UPC-A Check Digit
28h
Enable
11-14
Transmit UPC-E Check Digit
29h
Enable
11-15
Page 161
Symbologies 11 - 3
Table 11-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Transmit UPC-E1 Check Digit
2Ah
Enable
11-15
UPC-A Preamble
22h
System Character
11-16
UPC-E Preamble
23h
System Character
11-17
UPC-E1 Preamble
24h
System Character
11-18
Convert UPC-E to A
25h
Disable
11-19
Convert UPC-E1 to A
26h
Disable
11-19
EAN-8/JAN-8 Extend
27h
Disable
11-20
Bookland ISBN Format
F1h 40h
ISBN-10
11-21
UCC Coupon Extended Code
55h
Disable
11-22
Code 128
08h
Enable
11-22
UCC/EAN-128
0Eh
Enable
11-23
ISBT 128
54h
Enable
11-24
Code 39
00h
Enable
11-25
Trioptic Code 39
0Dh
Disable
11-25
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
11-26
Code 32 Prefix
E7h
Disable
11-26
Set Length(s) for Code 39
12h 13h
2 to 55
11-27
Code 39 Check Digit Verification
30h
Disable
11-29
Transmit Code 39 Check Digit
2Bh
Disable
11-29
Code 39 Full ASCII Conversion
11h
Disable
11-30
Buffer Code 39
71h
Disable
11-31
Code 93
09h
Disable
11-34
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
11-34
Code 11
0Ah
Disable
11-36
Set Lengths for Code 11
1Ch 1Dh
4 to 55
11-36
Code 128
Code 39
Code 93
Code 11
Page 162
11 - 4 Symbol MS4404/MS4407 Integration Guide
Table 11-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Code 11 Check Digit Verification
34h
Disable
11-38
Transmit Code 11 Check Digit(s)
2Fh
Disable
11-39
Interleaved 2 of 5 (ITF)
06h
Enable
11-39
Set Lengths for I 2 of 5
16h 17h
14
11-40
I 2 of 5 Check Digit Verification
31h
Disable
11-42
Transmit I 2 of 5 Check Digit
2Ch
Disable
11-42
Convert I 2 of 5 to EAN 13
52h
Disable
11-43
Discrete 2 of 5
05h
Disable
11-43
Set Length(s) for D 2 of 5
14h 15h
12
11-44
Codabar
07h
Disable
11-46
Set Lengths for Codabar
18h 19h
5 to 55
11-46
CLSI Editing
36h
Disable
11-48
NOTIS Editing
37h
Disable
11-48
MSI
0Bh
Disable
11-49
Set Length(s) for MSI
1Eh 1Fh
4 to 55
11-50
MSI Check Digits
32h
One
11-52
Transmit MSI Check Digit
2Eh
Disable
11-52
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
11-53
Inverse 1D
F1h 4Ah
Regular
11-54
US Postnet
59h
Enable
11-55
US Planet
5Ah
Enable
11-55
UK Postal
5Bh
Enable
11-56
Transmit UK Postal Check Digit
60h
Enable
11-56
Japan Postal
F0h 22h
Enable
11-57
Australian Postal
F0h 23h
Enable
11-57
Interleaved 2 of 5 (ITF)
Discrete 2 of 5 (DTF)
Codabar (NW - 7)
MSI
Postal Codes
Page 163
Symbologies 11 - 5
Table 11-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Dutch Postal
F0h 46h
Enable
11-58
4State Postal
F1h 50h
Disable
11-58
Transmit US Postal Check Digit
5Fh
Enable
11-59
GS1 DataBar (Formerly RSS, Reduced Space Symbology) GS1 DataBar-14
F0h 52h
Enable
11-60
GS1 DataBar Limited
F0h 53h
Enable
11-60
GS1 DataBar Expanded
F0h 54h
Enable
11-61
Convert GS1 DataBar to UPC/EAN
F0h 8Dh
Disable
11-61
Composite CC-C
F0h 55h
Disable
11-62
Composite CC-A/B
F0h 56h
Disable
11-62
Composite TLC-39
F0h 73h
Disable
11-63
UPC Composite Mode
F0h 58h
Always Linked
11-63
Composite Beep Mode
F0h 8Eh
Beep As Each Code Type is Decoded
11-64
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes
F0h ABh
Disable
11-65
PDF417
0Fh
Enable
11-66
MicroPDF417
E3h
Disable
11-66
Code 128 Emulation
7Bh
Disable
11-67
Data Matrix
F0h 24h
Enable
11-68
Data Matrix Inverse
F1h 4Ch
Regular
11-68
Maxicode
F0h 26h
Enable
11-69
QR Code
F0h 25h
Enable
11-70
MicroQR
F1h 3Dh
Enable
11-70
QR Inverse
F1h 4Bh
Regular
11-71
Aztec
F1h 3Eh
Enable
11-71
Aztec Inverse
F1h 4Dh
Regular
11-72
Composite
2-D Symbologies
Page 164
11 - 6 Symbol MS4404/MS4407 Integration Guide
Table 11-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Symbology-Specific Security Levels Redundancy Level
4Eh
1
11-73
Security Level
4Dh
1
11-75
Intercharacter Gap Size
F0h 7Dh
Normal
11-76
Report Version
11-76
Macro PDF Macro PDF Transmit/Decode Mode Symbols
BCh
Passthrough Mode
11-78
Transmit Macro PDF Control Header
B8h
Disable
11-79
Escape Characters
E9h
None
11-79
Flush Macro PDF Buffer
11-80
Abort Macro PDF Entry
11-80
Page 165
Symbologies 11 - 7
UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, capture the appropriate bar code below.
*Enable UPC-A (01h)
Disable UPC-A (00h)
Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, capture the appropriate bar code below.
*Enable UPC-E (01h)
Disable UPC-E (00h)
Page 166
11 - 8 Symbol MS4404/MS4407 Integration Guide
Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, capture the appropriate bar code below. NOTE
UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
Enable UPC-E1 (01h)
*Disable UPC-E1 (00h)
Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, capture the appropriate bar code below.
*Enable EAN-8/JAN-8 (01h)
Disable EAN-8/JAN-8 (00h)
Page 167
Symbologies 11 - 9
Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, capture the appropriate bar code below.
*Enable EAN-13/JAN-13 (01h)
Disable EAN-13/JAN-13 (00h)
Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, capture the appropriate bar code below.
Enable Bookland EAN (01h)
*Disable Bookland EAN (00h)
NOTE
If you enable Bookland EAN, select a Bookland ISBN Format on page 11-21. Also select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 11-10..
Page 168
11 - 10 Symbol MS4404/MS4407 Integration Guide
Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available:
• If you select Ignore UPC/EAN with Supplementals, and the scanner is presented with a UPC/EAN plus supplemental symbol, the scanner decodes UPC/EAN and ignores the supplemental characters.
• If you select Decode UPC/EAN with Supplementals, the scanner only decodes UPC/EAN symbols with supplemental characters, and ignores symbols without supplementals.
• If you select Autodiscriminate UPC/EAN Supplementals, the scanner decodes UPC/EAN symbols with supplemental characters immediately. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 11-14 before transmitting its data to confirm that there is no supplemental.
• If you select one of the following Supplemental Mode options, the scanner immediately transmits EAN-13 bar codes starting with that prefix that have supplemental characters. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 11-14 before transmitting its data to confirm that there is no supplemental. The scanner transmits UPC/EAN bar codes that do not have that prefix immediately. • Enable 378/379 Supplemental Mode • Enable 978/979 Supplemental Mode NOTE
If you select 978/979 Supplemental Mode and are scanning Bookland EAN bar codes, see Enable/Disable Bookland EAN on page 11-9 to enable Bookland EAN, and select a format using Bookland ISBN Format on page 11-21.
• Enable 977 Supplemental Mode • Enable 414/419/434/439 Supplemental Mode • Enable 491 Supplemental Mode • Enable Smart Supplemental Mode - applies to EAN-13 bar codes starting with any prefix listed previously. • Supplemental User-Programmable Type 1 - applies to EAN-13 bar codes starting with a 3-digit user-defined prefix. Set this 3-digit prefix using User-Programmable Supplementals on page 11-13. • Supplemental User-Programmable Type 1 and 2 - applies to EAN-13 bar codes starting with either of two 3-digit user-defined prefixes. Set the 3-digit prefixes using User-Programmable Supplementals on page 11-13. • Smart Supplemental Plus User-Programmable 1 - applies to EAN-13 bar codes starting with any prefix listed previously or the user-defined prefix set using User-Programmable Supplementals on page 11-13. • Smart Supplemental Plus User-Programmable 1 and 2 - applies to EAN-13 bar codes starting with any prefix listed previously or one of the two user-defined prefixes set using User-Programmable Supplementals on page 11-13. NOTE
To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters.