Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 39

Symbol MS4404/MS4407 Integration Guide: Symbol MS4404 - RS-232 (Serial) Interface, pages 115 to 122

Pages 115 to 122 of 310, from Symbol MS4404/MS4407 Integration Guide

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-4407

Page 115

Chapter 9 Symbol MS4404 - RS-232 (Serial) Interface Overview This chapter describes how to set up the Symbol MS4404 with a serial host. The serial interface is used to connect the Symbol MS4404 to point-of-sale devices, host computers, or other devices with an available serial port (e.g., com port). If the host is not listed in Table 9-2, refer to the documentation for the host device to set communication parameters to match the host. NOTE

The Symbol MS4404 uses RS-232C signal levels. Throughout the programming bar code menus, default values are indicated with asterisks (*).

.

* Indicates Default

NOTE

*Baud Rate 57,600

Feature/Option

The serial host type requires proper configuration of the sysconfig lines, and typically require using bar code menus as part of initial configuration. Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.

Page 116

9-2

Symbol MS4404/MS4407 Integration Guide

Serial Parameter Defaults Table 9-1 lists the defaults for serial host parameters. To change any option, capture the appropriate bar code(s) provided in the Serial Host Parameters section beginning on page 9-3. NOTE

See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Table 9-1 Serial Host Default Table

Parameter

Default

Page Number

Serial Host Parameters Serial Host Types

SSI Host

9-5

Baud Rate

9600

9-6

Parity Type

None

9-8

Stop Bit Select

1 Stop Bit

9-8

Data Bits

8-Bit

9-9

Check Receive Errors

Enable

9-9

Hardware Handshaking

None

9-10

Software Handshaking

None

9-12

Host Serial Response Time-out

2 Sec

9-14

RTS Line State

Low RTS

9-15

Beep on <BEL>

Disable

9-15

Intercharacter Delay

0 msec

9-16

Nixdorf Beep/LED Options

Normal Operation

9-17

Ignore Unknown Characters

Send Bar Code

9-17

Page 117

Symbol MS4404 - RS-232 (Serial) Interface

9-3

Serial Host Parameters Various serial hosts are set up with their own parameter default settings (Table 9-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below. Table 9-2

Terminal Specific Serial

Parameter

ICL

Fujitsu

Wincor-Nixdorf Mode A

Wincor-Nixdorf Mode B/OPOS/JPOS

Olivetti

Omron

Transmit Code ID

Yes

Yes

Yes

Yes

Yes

Yes

Data Transmission Format

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/ Suffix

Data/Suffix

Suffix

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

9600

Parity

Even

None

Odd

Odd

Even

None

Hardware Handshaking

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

None

None

Software Handshaking

None

None

None

None

Ack/Nak

None

Serial Response Time-out

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

Disable

RTS Line State

High

Low

Low

Low = No data to send

Low

High

Prefix

None

None

None

None

STX (1003)

None

*In the Nixdorf Mode B, if CTS is Low, imaging is disabled. When CTS is High, you can capture bar codes. **If you select Nixdorf Mode B and the imager is not connected to the proper host, it may appear unable to decode. If this happens, select a different serial host type within 5 seconds of cycling power to the imager. Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 9-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.

Page 118

9-4

Symbol MS4404/MS4407 Integration Guide

Table 9-3

Terminal Specific Code ID Characters ICL

Fujitsu

Wincor-Nixdorf Mode A

Wincor-Nixdorf Mode B/OPOS/JPOS

Olivetti

Omron

UPC-A

A

A

A

A

A

A

UPC-E

E

E

C

C

C

E

EAN-8/JAN-8

FF

FF

B

B

B

FF

EAN-13/JAN-13

F

F

A

A

A

F

Code 39

C <len>

None

M

M

M <len>

C <len>

Codabar

N <len>

None

N

N

N <len>

N <len>

Code 128

L <len>

None

K

K

K <len>

L <len>

I 2 of 5

I <len>

None

I

I

I <len>

I <len>

Code 93

None

None

L

L

L <len>

None

D 2 of 5

H <len>

None

H

H

H <len>

H <len>

UCC/EAN 128

L <len>

None

P

P

P <len>

L <len>

MSI

None

None

O

O

O <len>

None

Bookland EAN

F

F

A

A

A

F

Trioptic

None

None

None

None

None

None

Code 11

None

None

None

None

None

None

IATA

H<len>

None

H

H

None

None

Code 32

None

None

None

None

None

None

Other

None

None

None

None

None

None

Page 119

Symbol MS4404 - RS-232 (Serial) Interface

9-5

Serial Host Types To select a serial host interface, capture one of the following bar codes.

Enable SSI Host (No Variant)*

ICL Serial

Wincor-Nixdorf Serial Mode A

Wincor-Nixdorf Serial Mode B

Olivetti ORS4500

Omron

*Selecting Enable SSI Host (No Variant) activates the serial driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another serial host type bar code changes these settings.

Page 120

9-6

Symbol MS4404/MS4407 Integration Guide

Serial Host Types (continued)

OPOS/JPOS

Fujitsu Serial

Baud Rate Baud rate is the number of bits of data transmitted per second. Set the imager's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.

Baud Rate 600

Baud Rate 1200

Baud Rate 2400

Baud Rate 4800

Page 121

Symbol MS4404 - RS-232 (Serial) Interface

Baud Rate (continued)

*Baud Rate 9600

Baud Rate 19,200

Baud Rate 38,400

Baud Rate 57,600

Baud Rate 115,200

9-7

Page 122

9-8

Symbol MS4404/MS4407 Integration Guide

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

• Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

• Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

• Select None when no parity bit is required.

Odd

Even

*None Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

*1 Stop Bit

2 Stop Bits