The text of a manual · part 17 of 39
Symbol MS4404/MS4407 Integration Guide: Symbol MS4404 - RS-232 (Serial) Interface, pages 115 to 122
Pages 115 to 122 of 310, from Symbol MS4404/MS4407 Integration Guide
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-4407
Page 115
Chapter 9 Symbol MS4404 - RS-232 (Serial) Interface Overview This chapter describes how to set up the Symbol MS4404 with a serial host. The serial interface is used to connect the Symbol MS4404 to point-of-sale devices, host computers, or other devices with an available serial port (e.g., com port). If the host is not listed in Table 9-2, refer to the documentation for the host device to set communication parameters to match the host. NOTE
The Symbol MS4404 uses RS-232C signal levels. Throughout the programming bar code menus, default values are indicated with asterisks (*).
.
* Indicates Default
NOTE
*Baud Rate 57,600
Feature/Option
The serial host type requires proper configuration of the sysconfig lines, and typically require using bar code menus as part of initial configuration. Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Page 116
9-2
Symbol MS4404/MS4407 Integration Guide
Serial Parameter Defaults Table 9-1 lists the defaults for serial host parameters. To change any option, capture the appropriate bar code(s) provided in the Serial Host Parameters section beginning on page 9-3. NOTE
See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 9-1 Serial Host Default Table
Parameter
Default
Page Number
Serial Host Parameters Serial Host Types
SSI Host
9-5
Baud Rate
9600
9-6
Parity Type
None
9-8
Stop Bit Select
1 Stop Bit
9-8
Data Bits
8-Bit
9-9
Check Receive Errors
Enable
9-9
Hardware Handshaking
None
9-10
Software Handshaking
None
9-12
Host Serial Response Time-out
2 Sec
9-14
RTS Line State
Low RTS
9-15
Beep on <BEL>
Disable
9-15
Intercharacter Delay
0 msec
9-16
Nixdorf Beep/LED Options
Normal Operation
9-17
Ignore Unknown Characters
Send Bar Code
9-17
Page 117
Symbol MS4404 - RS-232 (Serial) Interface
9-3
Serial Host Parameters Various serial hosts are set up with their own parameter default settings (Table 9-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below. Table 9-2
Terminal Specific Serial
Parameter
ICL
Fujitsu
Wincor-Nixdorf Mode A
Wincor-Nixdorf Mode B/OPOS/JPOS
Olivetti
Omron
Transmit Code ID
Yes
Yes
Yes
Yes
Yes
Yes
Data Transmission Format
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix/Data/ Suffix
Data/Suffix
Suffix
CR (1013)
CR (1013)
CR (1013)
CR (1013)
ETX (1002)
CR (1013)
Baud Rate
9600
9600
9600
9600
9600
9600
Parity
Even
None
Odd
Odd
Even
None
Hardware Handshaking
RTS/CTS Option 3
None
RTS/CTS Option 3
RTS/CTS Option 3
None
None
Software Handshaking
None
None
None
None
Ack/Nak
None
Serial Response Time-out
9.9 Sec.
2 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
Beep On <BEL>
Disable
Disable
Disable
Disable
Disable
Disable
RTS Line State
High
Low
Low
Low = No data to send
Low
High
Prefix
None
None
None
None
STX (1003)
None
*In the Nixdorf Mode B, if CTS is Low, imaging is disabled. When CTS is High, you can capture bar codes. **If you select Nixdorf Mode B and the imager is not connected to the proper host, it may appear unable to decode. If this happens, select a different serial host type within 5 seconds of cycling power to the imager. Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 9-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.
Page 118
9-4
Symbol MS4404/MS4407 Integration Guide
Table 9-3
Terminal Specific Code ID Characters ICL
Fujitsu
Wincor-Nixdorf Mode A
Wincor-Nixdorf Mode B/OPOS/JPOS
Olivetti
Omron
UPC-A
A
A
A
A
A
A
UPC-E
E
E
C
C
C
E
EAN-8/JAN-8
FF
FF
B
B
B
FF
EAN-13/JAN-13
F
F
A
A
A
F
Code 39
C <len>
None
M
M
M <len>
C <len>
Codabar
N <len>
None
N
N
N <len>
N <len>
Code 128
L <len>
None
K
K
K <len>
L <len>
I 2 of 5
I <len>
None
I
I
I <len>
I <len>
Code 93
None
None
L
L
L <len>
None
D 2 of 5
H <len>
None
H
H
H <len>
H <len>
UCC/EAN 128
L <len>
None
P
P
P <len>
L <len>
MSI
None
None
O
O
O <len>
None
Bookland EAN
F
F
A
A
A
F
Trioptic
None
None
None
None
None
None
Code 11
None
None
None
None
None
None
IATA
H<len>
None
H
H
None
None
Code 32
None
None
None
None
None
None
Other
None
None
None
None
None
None
Page 119
Symbol MS4404 - RS-232 (Serial) Interface
9-5
Serial Host Types To select a serial host interface, capture one of the following bar codes.
Enable SSI Host (No Variant)*
ICL Serial
Wincor-Nixdorf Serial Mode A
Wincor-Nixdorf Serial Mode B
Olivetti ORS4500
Omron
*Selecting Enable SSI Host (No Variant) activates the serial driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another serial host type bar code changes these settings.
Page 120
9-6
Symbol MS4404/MS4407 Integration Guide
Serial Host Types (continued)
OPOS/JPOS
Fujitsu Serial
Baud Rate Baud rate is the number of bits of data transmitted per second. Set the imager's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
Baud Rate 600
Baud Rate 1200
Baud Rate 2400
Baud Rate 4800
Page 121
Symbol MS4404 - RS-232 (Serial) Interface
Baud Rate (continued)
*Baud Rate 9600
Baud Rate 19,200
Baud Rate 38,400
Baud Rate 57,600
Baud Rate 115,200
9-7
Page 122
9-8
Symbol MS4404/MS4407 Integration Guide
Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
• Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
• Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.
• Select None when no parity bit is required.
Odd
Even
*None Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
*1 Stop Bit
2 Stop Bits