The text of a manual · part 10 of 39
Symbol MS4404/MS4407 Integration Guide, pages 57 to 70
Pages 57 to 70 of 310: Maintenance & Troubleshooting; User Preferences
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-4407
Page 57
Chapter 5 Maintenance & Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.
Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the exit window with a damp cloth and, if necessary, a non-ammonia based detergent.
Page 58
5-2
Symbol MS4404/MS4407 Integration Guide
Troubleshooting Problem No red LED or nothing happens during a capture attempt.
Possible Cause No power to the imager.
Possible Solutions Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.
Imager cannot read the bar code.
Interface/power cables are loose.
Re-connect loose cables.
Imager is not programmed for the correct bar code type.
Ensure the imager is programmed to read the type of bar code to be decoded. Try capturing other bar code(s) and other bar code types.
Laser activates, followed by a beep sequence.
NOTE
Incorrect communication parameters.
Set the correct communication parameters (baud rate, parity, stop bits, etc.)
Bar code symbol is unreadable.
Check the symbol to ensure it is not defaced. Try capturing similar symbols of the same code type.
Inappropriately hot environment.
Remove the imager from the hot environment, and allow it to cool down.
Beeper is configured.
Refer to Beeper Signals on page 3-3 for beeper indication descriptions.
If after performing these checks the symbol still does not decode, contact the distributor or contact Motorola Enterprise Mobility Support. See page xv for contact information.
Page 59
Chapter 6 User Preferences Overview This chapter describes each user preference feature and provides the programming bar codes necessary for selecting these features.
Host Selection Select a host type according to the pinout information in Table 4-2 on page 4-3 (connecting pins 4 and 8). The default serial host for the Symbol MS4404 is SSI and the default USB host for the Symbol MS4407 is SNAPI with Imaging, as these host types provide more flexibility during integration when configuring the unit via host command. Selecting other host configurations require using bar code menus and are not available via host programming. These hosts do not support host triggering, and require a method to trigger the reader for initial configuration. Use caution when selecting one of these hosts. Be sure to consider how setting up via bar code menu, which includes providing a triggering method, can impact integration. See each host chapter for configuration options for each host type.
Changing Default Values The imager ships with the settings shown in User Preferences Default Table on page 6-3 (also see Appendix A, Standard Defaults for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value:
• Capture the appropriate bar codes in this guide. These new values replace the standard default values in memory.
• For SSI and USB SNAPI hosts, send a “parameter send” command from the host system. Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer Guide for detailed instructions for changing parameter values using this method.
Page 60
6-2
Symbol MS4404/MS4407 Integration Guide
NOTE
Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
To return all features to default values, capture Set Default Parameter on page 6-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*High Volume
Feature/Option
(00h) Option Hex Value for programming via SSI command
Imaging Sequence Examples In most cases, capturing one bar code sets the parameter value. For example, to set the beeper tone to high, capture the High Frequency (beeper tone) bar code listed under Beeper Tone on page 6-4. The imager issues a fast warble beep signal and a good decode LED signal, signifying a successful parameter entry. Other parameters, such as Presentation Mode Session Timeout, require capturing several bar codes. See these parameter descriptions for this procedure.
Errors While Decoding Unless otherwise specified, to correct an error during a decoding sequence, just re-capture the correct parameter.
Page 61
User Preferences
6-3
User Preferences Parameter Defaults Table 6-1 lists defaults for user preferences parameters. To change any parameter value, capture the appropriate bar code(s) provided in User Preferences on page 6-3. NOTE
Table 6-1
See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters.
User Preferences Default Table Parameter Number
Parameter
Default
Page Number
User Preferences Set Default Parameter
All Defaults
6-3
Parameter Scanning
ECh
Enable
6-4
Beeper Tone
91h
Medium
6-4
Beeper Volume
8Ch
High
6-5
Trigger Mode
8Ah
Presentation
6-6
Picklist Mode
F0h 92h
Disabled Always
6-7
Power Mode
80h
Continuous On
6-8
Time Delay to Low Power Mode
92h
1.0 Sec
6-8
Decode Session Timeout
88h
9.9 Sec
6-9
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
6-10
Beep After Good Decode
38h
Enable
6-10
Presentation Mode Session Timeout
F0h, 90h
2 Seconds
6-11
User Preferences Set Default Parameter Capture this bar code to return all parameters to the default values listed in Table A-1 on page A-1.
*Set All Defaults
Page 62
6-4
Symbol MS4404/MS4407 Integration Guide
Parameter Scanning Parameter # ECh To disable decoding of parameter bar codes, capture the Disable Parameter Scanning bar code below. Note that you can still decode the Set Defaults parameter bar code. To enable decoding of parameter bar codes, capture either Enable Parameter Scanning or Set All Defaults.
*Enable Parameter Scanning (01h)
Disable Parameter Scanning (00h)
Beeper Tone Parameter # 91h To select a decode beep frequency (tone), capture the Low Frequency, Medium Frequency, or High Frequency bar code.
Low Frequency (02h)
*Medium Frequency (Optimum Setting) (01h)
High Frequency (00h)
Page 63
User Preferences
Beeper Volume Parameter # 8Ch To select a beeper volume, capture the Low Volume, Medium Volume, or High Volume bar code.
Low Volume (02h)
Medium Volume (01h)
*High Volume (00h)
6-5
Page 64
6-6
Symbol MS4404/MS4407 Integration Guide
Trigger Mode Parameter # 8Ah • Level - A trigger event activates decode processing, which continues until the trigger event ends, a valid decode, or the decode session time-out is reached.
• Presentation Mode - When the Symbol MS440X detects an object in its field of view it triggers and attempt to decode. The range of object detection does not vary under normal lighting conditions. This applies to decode mode only. In this mode the unit does not enter its sleep state.
• Host - A host command issues the triggering signal. The Symbol MS440X interprets a trigger pull as a level triggering option.
Level (00h)
*Presentation Mode (07h)
Host (08h)
Page 65
User Preferences
6-7
Picklist Mode Parameter # F0h 92h Picklist mode enables the imager to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the imager:
• Disabled Always (default) - Picklist mode is always disabled. • Enabled Out of Scanstand - Picklist mode is enabled when the imager is out of Scanstand mode and disabled when the imager is in Scanstand mode.
• Enabled Always- Picklist mode is always enabled.
*Disabled Always (00h)
Enabled Out of Scanstand (01h)
Enabled Always (02h)
Page 66
6-8
Symbol MS4404/MS4407 Integration Guide
Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In low power mode, the imager enters into a low power consumption mode to preserve battery life after each decode attempt. In continuous power mode, power remains on after each decode attempt.
*Continuous On (00h)
Low Power Mode (01h)
Time Delay to Low Power Mode Parameter # 92h This parameter sets the time the imager remains active after decoding. The imager wakes upon trigger pull or when the host attempts to communicate with the imager. NOTE
This parameter only applies when Power Mode is set to Low Power. To program a different value for this parameter than those provided below, see the Simple Serial Interface (SSI) Programmer Guide.
*1 Second (11h)
5 Seconds (15h)
Page 67
User Preferences
6-9
Time Delay to Low Power Mode (continued)
1 Minute (21h)
5 Minutes (25h)
15 Minutes (2Bh)
1 Hour (31h)
Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a decode attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, capture the bar code below. Next, capture two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set a Decode Session Timeout of 0.5 seconds, capture the bar code below, then capture the 0 and 5 bar codes. To correct an error or change the selection, capture Cancel on page D-3.
Decode Session Timeout
Page 68
6 - 10 Symbol MS4404/MS4407 Integration Guide
Timeout Between Decodes, Same Symbol Parameter # 89h This option is used in presentation mode to prevent multiple reads of a symbol left in the Symbol MS440X field of view. The timeout begins when the symbol is removed from the field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds. To select the timeout between decodes for the same symbol, capture the bar code below, then capture two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.
Timeout Between Decodes, Same Symbol
Beep After Good Decode Parameter # 38h Capture a bar code below to select whether or not the imager issues a beep signal after a good decode. If selecting Do Not Beep After Good Decode, beeper signals are issued during parameter menu imaging and to indicate error conditions.
*Beep After Good Decode (Enable) (01h)
Do Not Beep After Good Decode (Disable) (00h)
Page 69
User Preferences 6 - 11
Presentation Mode Session Timeout Parameter # F0h, 90h To set the duration of the attempt to decode a bar code detected in presentation mode, capture the bar code below. Next, capture three numeric bar codes from Appendix D, Numeric Bar Codes to select a value between 1 and 255 that represents tenths of a second. Single digit numbers must have a leading zero. For example, to set 0.5 seconds, capture the bar code below, then capture the 0, 0, 5 bar codes. To correct an error or change the selection, capture Cancel on page D-3. The default value is 2 seconds.
Presentation Mode Session Timeout
Page 70
6 - 12 Symbol MS4404/MS4407 Integration Guide