Page 259
RS-232 Interface
ACK/NAK When this option is selected, after transmitting data, the scanner expects either an ACK or NAK response from the host. When the scanner receives a NAK, it re-transmits the data and waits for either an ACK or NAK. After three unsuccessful attempts to send data, the scanner issues an error indication and discards the data. The scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the scanner does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.
ACK/NAK
ENQ When this option is selected, the scanner waits for an ENQ character from the host before transmitting data. If the scanner does not receive an ENQ within the Host Serial Response Time-out, it issues an error indication and discards the data. The host must transmit an ENQ character at least every Host Serial Response Time-out to prevent transmission errors.
ENQ
11-17
Page 260
MS XX07 Series Integration Guide
ACK/NAK with ENQ This combines the two previous options.
ACK/NAK with ENQ
XON/XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character. There are two situations for XON/XOFF: •
XOFF is received before the scanner has data to send. When the scanner has data to send, it waits up to Host Serial Response Time-out for an XON character before transmission. If the scanner does not receive an XON within this time, it issues an error indication and discards the data.
•
XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.
XON/XOFF
11-18
Page 261
RS-232 Interface
Host Serial Response Time-out This parameter specifies how long the scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when an ACK/NAK Software Handshaking mode or RTS/CTS Hardware Handshaking is enabled.
*Minimum: 2 Sec
Low: 2.5 Sec
Medium: 5 Sec
High: 7.5 Sec
Maximum: 9.9 Sec
11-19
Page 262
MS XX07 Series Integration Guide
RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state.
*Host: Low RTS
Host: High RTS
Beep on <BEL> When this parameter is enabled, the scanner issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
Beep On <BEL> Character (Enable)
*Do Not Beep On <BEL> Character (Disable)
11-20
Page 263
RS-232 Interface
Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions.
*Minimum: 0 msec
Low: 25 msec
Medium: 50 msec
High: 75 msec
Maximum: 99 msec
11-21
Page 264
MS XX07 Series Integration Guide
Nixdorf Beep/LED Options When Nixdorf Mode B is selected, this indicates when the scanner beeps and turns on its LED after a decode.
*Normal Operation (Beep/LED immediately after decode)
Beep/LED After Transmission
Beep/LED After CTS Pulse
11-22
Page 265
RS-232 Interface
Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes with Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then four (error) beeps sound on the scanner.
*Send Bar Code (with unknown characters)
Do Not Send Bar Codes (with unknown characters)
11-23
Page 266
MS XX07 Series Integration Guide
11-24