For the Symbol MS-1207

Page 243

Chapter 11 RS-232 Interface

Introduction This chapter provides RS-232 host information for setting up the MiniScan XX07 Series scanner. The RS-232 interface is used to attach the MiniScan scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If your host is not listed in Table 11-2, set the communication parameters to match the host device. Refer to the documentation for the host device. This scanner uses TTL RS-232 levels which interfaces with all PC's with no additional hardware. Note: Particularly noisy electrical environments may require a cable with an RS-232 transceiver. To obtain this cable contact the Symbol Support Center. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates Default

*Baud Rate 9600

Feature/Option

11-1

Page 244

MS XX07 Series Integration Guide

RS-232 Default Parameters Table 11-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 11-6. Note: See Chapter 9, Maintenance and Troubleshooting for all user preferences, hosts, symbologies, and miscellaneous parameters. Table 11-1. RS-232 Host Default Table Parameter

Default

Page Number

RS-232 Host Parameters RS-232 Host Types

Standard1

11-6

Baud Rate

9600

11-9

Parity Type

None

11-11

Stop Bit Select

1 Stop Bit

11-12

Data Bits

8-Bit

11-12

Check Receive Errors

Enable

11-13

Hardware Handshaking

None

11-15

Software Handshaking

None

11-16

Host Serial Response Time-out

2 Sec

11-19

RTS Line State

Low RTS

11-20

Beep on <BEL>

Disable

11-20

Intercharacter Delay

0 msec

11-21

Nixdorf Beep/LED Options

Normal Operation

11-22

1

User selection is required to configure this interface; this is the most common selection.

11-2

Page 245

RS-232 Interface

Table 11-1. RS-232 Host Default Table (Continued) Parameter Ignore Unknown Characters 1

Default Send Bar Code

Page Number 11-23

User selection is required to configure this interface; this is the most common selection.

11-3

Page 246

MS XX07 Series Integration Guide

RS-232 Host Parameters Various RS-232 hosts are configured with their own parameter default settings (Table 112). Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, or standard sets the defaults listed below. Table 11-2. Terminal Specific RS-232 Parameter

Standard (Default)

ICL

Fujitsu

WincorNixdorf Mode A

WincorNixdorf Mode B/ OPOS

Olivetti

Omron

Transmit Code ID No

Yes

Yes

Yes

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/ Suffix

Data/ Suffix

Data/Suffix

Data/Suffix

Prefix/Data/ Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013) CR (1013) CR (1013)

CR (1013)

ETX (1003)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

9600

9600

Parity

None

Even

None

Odd

Odd

Even

None

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

None

None

Software Handshaking

None

None

None

None

None

Ack/Nak

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

Disable

Disable

RTS Line State

Low

High

Low

Low

Low = No data to send

Low

High

Prefix

None

None

None

None

None

STX (1002)

None

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes. **If Nixdorf Mode B is scanned without the scanner connected to the proper host, the scanner may not be able to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.

11-4

Page 247

RS-232 Interface

RS-232 Host Parameters (continued) Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS, Olivetti, or Omron terminal enables the transmission of code ID characters listed in Table 11-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals. Table 11-3. Terminal-Specific Code ID Characters Parameter

ICL

WincorNixdorf Mode A

Fujitsu

WincorNixdorf Mode B/OPOS

Olivetti

Omron

UPC-A

A

A

A

A

A

A

UPC-E

E

E

C

C

C

E

EAN-8/JAN-8

FF

FF

B

B

B

FF

EAN-13/JAN-13

F

F

A

A

A

F

Code 39

C <len>

None

M

M

M <len>

C <len>

Codabar

N <len>

None

N

N

N <len>

N <len>

Code 128

L <len>

None

K

K

K <len>

L <len>

I 2 of 5

I <len>

None

I

I

I <len>

I <len>

Code 93

None

None

L

L

L <len>

None

D 2 of 5

H <len>

None

H

H

H <len>

H <len>

UCC/EAN 128

L <len>

None

P

P

P <len>

L <len>

MSI

None

None

O

O

O <len>

None

Bookland EAN

F

F

A

A

A

F

Trioptic

None

None

None

None

None

None

Code 11

None

None

None

None

None

None

IATA

H<len>

None

H

H

None

None

Code 32

None

None

None

None

None

None

11-5

Page 248

MS XX07 Series Integration Guide

RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. Note: You must select an interface as there is no default; Standard RS-232 is the most common selection.

Standard RS-232

ICL RS-232

Wincor-Nixdorf RS-232 Mode A

Wincor-Nixdorf RS-232 Mode B

11-6

Page 249

RS-232 Interface

RS-232 Host Types (continued)

Olivetti ORS4500

Omron

OPOS/JPOS

Fujitsu RS-232

11-7

Page 250

MS XX07 Series Integration Guide

Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the baud rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Baud Rate 600

Baud Rate 1200

Baud Rate 2400

Baud Rate 4800

11-8