Page 197

Parameter Menus

MSI Plessey Enable/Disable MSI Plessey Parameter # 0Bh To enable or disable MSI Plessey, scan the appropriate bar code below.

Enable MSI Plessey (01h)

*Disable MSI Plessey (00h)

10-89

Page 198

MS XX07 Series Integration Guide

Set Lengths for MSI Plessey Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. Lengths for MSI Plessey can be set for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select MSI Plessey One Discrete Length, then scan 1, 4, to decode only MSI Plessey symbols containing 14 characters. Numeric bar codes begin on page 10-132. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.

MSI Plessey - One Discrete Length

Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select MSI Plessey Two Discrete Lengths, then scan 0, 2, 1, 4, to decode only MSI Plessey symbols containing 2 or 14 characters. Numeric bar codes begin on page 10-132. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.

MSI Plessey - Two Discrete Lengths

10-90

Page 199

Parameter Menus

Length Within Range - Select this option to decode codes within a specified range. For example, to decode MSI Plessey symbols containing between 4 and 12 characters, first scan MSI Plessey Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 10-132. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.

*MSI Plessey - Length Within Range

Any Length - Scan this option to decode MSI Plessey symbols containing any number of characters. Note: Selecting this option can cause misdecodes for MSI Plessey codes.

MSI Plessey - Any Length

10-91

Page 200

MS XX07 Series Integration Guide

MSI Plessey Check Digits Parameter # 32h These check digits at the end of the bar code verify the integrity of the data. At least one check digit is required. Check digits are not automatically transmitted with the data.

*One MSI Plessey Check Digit (00h)

If two check digits is selected, also select an MSI Plessey Check Digit Algorithm. See page 10-94.

Two MSI Plessey Check Digit (01h)

10-92

Page 201

Parameter Menus

Transmit MSI Plessey Check Digit Parameter # 2Eh Scan this symbol to transmit the check digit with the data.

Transmit MSI Plessey Check Digit (Enable) (01h)

Scan this symbol to transmit data without the check digit.

*Do Not Transmit MSI Plessey Check Digit (Disable) (00h)

10-93

Page 202

MS XX07 Series Integration Guide

MSI Plessey Check Digit Algorithm Parameter # 33h When the Two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Select one of the following algorithms.

MOD 10/ MOD 11 (00h)

*MOD 10/ MOD 10 (01h)

10-94

Page 203

Parameter Menus

PDF417/MicroPDF417 Note: These options are supported by the MS 2207, MS 2207VHD, and MS 3207 only.

Enable/Disable PDF417 Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below.

Enable PDF417 (01h)

Disable PDF417 (00h)

10-95

Page 204

MS XX07 Series Integration Guide

Enable/Disable MicroPDF417 Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below.

Enable MicroPDF417 (01h)

*Disable MicroPDF417 (00h)

10-96

Page 205

Parameter Menus

MicroPDF Performance Parameter # F0h 65h If there are problems decoding MicroPDF symbols, select Selective Performance. F0h 65h This can decrease decoding aggressiveness on some symbols.

*Standard Performance for MicroPDF (00h)

Selective Performance for MicroPDF (03h)

10-97

Page 206

MS XX07 Series Integration Guide

Code 128 Emulation Parameter # 7Bh When this parameter is enabled, the scanner transmits data from certain MicroPDF417 symbols as if it was encoded in Code 128 symbols. Transmit AIM Symbology Identifiers must be enabled for this parameter to work. If Code 128 Emulation is enabled, these MicroPDF417 symbols are transmitted with one of the following prefixes: ]C1 if the first codeword is 903-907, 912, 914, 915

]C2 if the first codeword is 908 or 909

]C0 if the first codeword is 910 or 911

If disabled, they are transmitted with one of the following prefixes: ]L3 if the first codeword is 903-907, 912, 914, 915

]L4 if the first codeword is 908 or 909

]L5 if the first codeword is 910 or 911

Scan a bar code below to enable or disable Code 128 Emulation.

Enable Code 128 Emulation (01h)

*Disable Code 128 Emulation (00h)

10-98