Page 167
Parameter Menus
Code 32 Prefix Parameter # E7h Enable this parameter to add the prefix character “A” to all Code 32 bar codes. Convert Code 39 to Code 32 must be enabled for this parameter to function.
*Enable Code 32 Prefix (01h)
Disable Code 32 Prefix (00h)
10-59
Page 168
MS XX07 Series Integration Guide
Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. One Discrete Length - This option limits decodes to only those Code 39 symbols containing a selected length. Lengths are selected from the numeric bar codes beginning on page 10-132. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.
Code 39 - One Discrete Length
Two Discrete Lengths - This option limits decodes to only those Code 39 symbols containing either of two selected lengths. Lengths are selected from the numeric bar codes beginning on page 10-132. For example, to decode only those Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.
Code 39 - Two Discrete Lengths
10-60
Page 169
Parameter Menus
Length Within Range - This option limits decodes to only those Code 39 symbols within a specified range. The range is selected using the numeric bar codes beginning on page 10-132. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.
*Code 39 - Length Within Range
Any Length - Scan this option to decode Code 39 symbols containing any number of characters.
Code 39 - Any Length
10-61
Page 170
MS XX07 Series Integration Guide
Code 39 Check Digit Verification Parameter # 30h When this feature is enabled, the scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only those Code 39 symbols which include a modulo 43 check digit are decoded.
Enable Code 39 Check Digit (01h)
*Disable Code 39 Check Digit (00h)
10-62
Page 171
Parameter Menus
Transmit Code 39 Check Digit Parameter # 2Bh Scan this symbol to transmit the check digit with the data.
Transmit Code 39 Check Digit (Enable) (01h)
Scan this symbol to transmit data without the check digit.
*Do Not Transmit Code 39 Check Digit (Disable) (00h)
10-63
Page 172
MS XX07 Series Integration Guide
Enable/Disable Code 39 Full ASCII Parameter # 11h To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent of ABC ENTER. Do not enable Code 39 Full ASCII and Trioptic Code 39 simultaneously. The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.
Enable Code 39 Full ASCII (01h)
*Disable Code 39 Full ASCII (00h)
10-64
Page 173
Parameter Menus
Code 39 Decode Performance Parameter # 46h Note: This option is supported by the MS 2207, MS 2207VHD, and MS 3207 only. This option offers three levels of decode performance or “aggressiveness” for Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation, which is useful when scanning very long and/or truncated bar codes. Increased levels reduce decode security. If you enable this option, you can select a Decode Performance level from the next page to suit performance needs. Note: This option only works with Code 39 One Discrete Length.
*Enable Code 39 Decode Performance (01h)
Disable Code 39 Decode Performance (00h)
10-65
Page 174
MS XX07 Series Integration Guide
Code 39 Decode Performance Level Parameter # 47h Note: This option is supported by the MS 2207, MS 2207VHD, and MS 3207 only. Select a level of decode performance.
Code 39 Decode Performance Level 1 (03h)
Code 39 Decode Performance Level 2 (02h)
*Code 39 Decode Performance Level 3 (01h)
10-66
Page 175
Parameter Menus
Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below.
Enable Code 93 (01h)
*Disable Code 93 (00h)
10-67
Page 176
MS XX07 Series Integration Guide
Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Code 93 can be set for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select Code 93 One Discrete Length, then scan 1, 4, to limit decoding to only Code 93 symbols containing 14 characters. Numeric bar codes begin on page 10-132. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.
Code 93 - One Discrete Length
Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4, to limit the decoding to only Code 93 symbols containing 2 or 14 characters. Numeric bar codes begin on page 10-132. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134.
Code 93 - Two Discrete Lengths
10-68