Page 137

Parameter Menus

Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.

*Enable UPC-E (01h)

Disable UPC-E (00h)

10-29

Page 138

MS XX07 Series Integration Guide

Enable/Disable UPC-E1 Parameter # 0Ch To enable or disable UPC-E1, scan the appropriate bar code below.

Enable UPC-E1 (01h)

*Disable UPC-E1 (00h)

10-30

Page 139

Parameter Menus

Enable/Disable EAN-8 Parameter # 04h To enable or disable EAN-8, scan the appropriate bar code below.

*Enable EAN-8 (01h)

Disable EAN-8 (00h)

10-31

Page 140

MS XX07 Series Integration Guide

Enable/Disable EAN-13 Parameter # 03h To enable or disable EAN-13, scan the appropriate bar code below.

*Enable EAN-13 (01h)

Disable EAN-13 (00h)

10-32

Page 141

Parameter Menus

Enable/Disable Bookland EAN Parameter # 53h To enable or disable EAN Bookland, scan the appropriate bar code below.

Enable Bookland EAN (01h)

*Disable Bookland EAN (00h)

10-33

Page 142

MS XX07 Series Integration Guide

UPC/EAN Coupon Code Parameter # 55h When enabled, this parameter decodes UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/EAN-128 Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.

Enable UPC/EAN Coupon Code

*Disable UPC/EAN Coupon Code

Note: Use the Decode UPC/EAN Supplemental Redundancy parameter to control autodiscrimination of the EAN-128 (right half) of a coupon code.

10-34

Page 143

Parameter Menus

Decode UPC/EAN Supplementals Parameter # 10h Supplementals are appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). Three options are available. •

If UPC/EAN with supplemental characters is selected, the scanner does not decode UPC/EAN symbols without supplemental characters.

•

If UPC/EAN without supplemental characters is selected, and the MiniScan is presented with a UPC/EAN plus supplemental symbol, the scanner decodes the UPC/EAN and ignores the supplemental characters.

•

If autodiscriminate is selected, scan Decode UPC/EAN Supplemental Redundancy on page 10-37, then select a value from the numeric bar codes beginning on page 10-132. A value of 5 or more is recommended.

•

If Enable 378/379 Supplemental Mode is selected, the scanner identifies supplementals for EAN-13 bar codes starting with a ‘378’ or ‘379’ prefix only. All other UPC/EAN bar codes are decoded immediately and the supplemental characters ignored.

•

If Enable 978 Supplemental Mode is selected, the scanner identifies supplementals for EAN-13 bar codes starting with a ‘978’ prefix only. All other UPC/ EAN bar codes are decoded immediately and the supplemental characters ignored.

•

If Enable Smart Supplemental Mode is selected, the scanner identifies supplementals for EAN-13 bar codes starting with a ‘378’, ‘379’, or ‘978’ prefix only. All other UPC/EAN bar codes are decoded immediately and the supplemental characters ignored. Note: To minimize the risk of invalid data transmission, we recommend selecting either read or ignore supplemental characters.

Select the desired option by scanning one of the following bar codes.

Decode UPC/EAN With Supplementals (01h)

10-35

Page 144

MS XX07 Series Integration Guide

Decode UPC/EAN Supplementals (continued)

*Ignore UPC/EAN With Supplementals (00h)

Autodiscriminate UPC/EAN Supplementals (02h)

Enable 378/379 Supplemental Mode (04h)

Enable 978 Supplemental Mode (05h)

Enable Smart Supplemental Mode (03h)

10-36

Page 145

Parameter Menus

Decode UPC/EAN Supplemental Redundancy Parameter # 50h With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times (from 2 to 30) a symbol without supplementals is decoded before transmission. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected. Scan the bar code below to select a decode redundancy value. Next scan two numeric bar codes beginning on page 10-132. Enter a leading zero for single digit numbers. To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 10-134.

Decode UPC/EAN Supplemental Redundancy

10-37

Page 146

MS XX07 Series Integration Guide

Transmit UPC-A Check Digit Parameter # 28h Scan the appropriate bar code below to transmit the symbol with or without the UPC-A check digit.

*Transmit UPC-A Check Digit (01h)

Do Not Transmit UPC-A Check Digit (00h)

10-38