The text of a manual · part 9 of 33
MiniScan MS XX04 Series Integration Guide: Chapter 5 MS 2204 Specifications
Pages 65 to 76 of 310, from MiniScan MS XX04 Series Integration Guide
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 65
Chapter 5 MS 2204 Specifications Overview This chapter provides the technical specifications for the MS 2204 scanner.
5-1
Page 66
MS XX04 Integration Guide
MS 2204 Electrical Interface
Figure 5-1. MiniScan Connector Table 5-1 lists the pin functions of the MiniScan MS 2204 interface.
Table 5-1. MS 2204 Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
4
Not used
5
Ground
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
5-2
O = Output
Power supply ground input and signal ground reference.
Page 67
MS 2204 Specifications
MS 2204 Mechanical Drawings
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 5-2. MS 2204 Mechanical Drawing
5-3
Page 68
MS XX04 Integration Guide
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 5-3. MS 2204 Mechanical Drawing
5-4
Page 69
MS 2204 Specifications
MS 2204 Technical Specifications Table 5-2 provides the MS 2204 technical specifications Table 5-2. MS 2204 Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level
5.0 VDC ± 10% 250 ± 30 mA typical 25 ± 5 mA typical 200 mV peak-to-peak max.
Laser Power
0.95 mW ± 0.1 mW, λ = 650 nm nominal
Scan Rate
640 scans/sec.
Scan Frequency: Horizontal
320 Hz ± 5 Hz
Scan Frequency: Vertical
282 Hz ± 5 Hz
Frame Rate
24 frames/sec. 12 Hz ±1 Hz (vertical)
Print Contrast
Minimum 35% absolute dark/light reflectance differential
Scan Angle
Horizontal: 34o ±1.5o Vertical: 34o ±1.5o
Scan Pattern
Smart raster, high density single scan line
Start Time
0.065 sec. to 75% of steady state horizontal amplitude
Skew Tolerance
± 15o from plane parallel to symbol (see Figure 5-4 on page 5-7)
Pitch Angle
± 30o from normal (see Figure 5-4 on page 5-7)
Roll
± 4o from (for scanning benchmark label, assuming 3:1 codeword aspect ratio) (see Figure 5-4 on page 5-7)
Decode Depth of Field
See Figure 5-5 on page 5-8 and Figure 5-6 on page 5-10
Beam Deviation (offset from the nominal)
Horizontal: ±3.0o Vertical: ±3.0o Horizontal tilt: ± 2o
5-5
Page 70
MS XX04 Integration Guide
Table 5-2. MS 2204 Technical Specifications @ 23°C (Continued) Item
Description
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
Multiple 30” drops
Vibration
Unpowered scanner withstands a random vibration along each of the X, Y and Z axes for a period of one hour per axis, defined as follows: 20 to 80 Hz Ramp up to 0.04 G^2/Hz at the rate of 3dB/ octave. 80 to 350 Hz 0.04 G^2/Hz 350 to 2000 Hz Ramp down at the rate of 3 dB/octave.
ESD
± 20kV air discharge ± 8kV indirect discharge
Sealing
IP54
Operating Temperature
-4° to 122°F (-20° to 50°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
Humidity
5% to 95% non-condensing
Laser Class
CDRH Class II, IEC Class 2
Height
1.60 in. (4.06 cm)
Width
2.28 in. (5.79 cm)
Depth
2.94 in. (7.47 cm)
Weight
4.73 oz. (134 gm)
5-6
Page 71
MS 2204 Specifications
Skew
Pitch
+ 49° from normal
+ 55° from normal
Pitch Angle
Skew Angle
15 mil Symbol
15 mil Symbo l
Scan Beam
10 in
10 in
. (2
. (2
54 m
54 m m)
m)
Scan Beam
Roll + 20° from normal Roll Angle mil 15 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
10 in
. (2
54 m m)
Scan Beam
Figure 5-4. Skew, Pitch and Roll 5-7
Page 72
MS XX04 Integration Guide
MS 2204 Decode Zones The decode zone is a function of various symbol characteristics including density, print contrast, wide to narrow ratio and edge acurity. Typical values are shown. Table 5-3 on page 5-9 and Table 5-4 on page 5-11 list the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-12.
MS 2204 1D Decode Zone Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Vcc = 5V
In.
cm
10 25.4 7.5 15.2
MS 22XX
6 mil 5.25
2.0 1.5
7.5 mil
10.1
2.5
5.1
0
0
2.5
5.1
5
10.1
7.5 15.2 10
7.0
13 mil Minimum Element Width
14.0
20 mil Minimum Element Width
19.0
40 mil Minimum Element Width
*
5
24.0
55 mil Minimum Element Width 31.0
In. cm
0 0
5 12.7
10 25.4
15 38.1
20 50.8
25 63.5
30 76.2
Depth of Field * Minimum distance determined by symbol length and scan angle.
Figure 5-5. MS 2204 1D Decode Distances 5-8
35 88.9
25.4
W i d t h o f F i e l d
Page 73
MS 2204 Specifications
MS 2204 1D Decode Distances Table 5-3. MS 2204 1D Decode Distances Symbol Density/ Symbol p/n / Bar Code Type
Bar Code Content/ Contrast1
Typical Working Ranges3
Guaranteed Working Ranges3
Near
Far
Near
Far
6.0 mil 60-01755-01 Code 39
123 80% MRD
2.0 in. 5.08 cm
5.25 in. 13.34 cm
2.75 in. 7.00 cm
4.0 in. 10.16 cm
7.5 mil 64-17452-01 Code 39
ABCDEF 80% MRD
1.5 in. 3.81 cm
7.0 in. 17.78 cm
2.25 in. 5.72 cm
5.0 in. 12.7 cm
13 mil 64-05303-01 100% UPC
012345678905 80% MRD
Note 2
14.0 in. 35.56 cm
N/A
10.5 in. 26.67 cm
20 mil 64-17456-01 Code 39
123 80% MRD
Note 2
19.0 in. 48.26 cm
N/A
14.0 in. 35.56 cm
40 mil 64-17457-01 Code 39
AB 80% MRD
Note 2
24.0 in. 60.96 cm
N/A
18.0 in. 45.72 cm
55 mil 60-01601-01 Code 39
A 80% MRD
Note 2
31.0 in. 78.74 cm
Note 2
25.0 in. 63.50 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.
5-9
Page 74
MS XX04 Integration Guide
MS 2204 2D Decode Zone Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Y-module dimension = 3X. Vcc = 5V
MS-220X
2.5 6.35
W i d t h
0 o f
In.
cm
5
12.7
0
2.5 6.35 6.6 mil
6.0
1.5
5
10 mil Minimum Element Width, 35% 8.0 3.5 10 mil Minimum Element Width, 80% 9.0 3.5 15 mil Minimum Element Width
5.6
In. cm
0 0
2 5.1
4 10.1
6 15.2
8 20.3
10 25.4
12 30.5
15.0
14 35.6
16 40.6
Depth of Field Figure 5-6. MS 2204 2D Slab/Raster Decode Distances
Note: Not optimized for omnidirectional mode.
5-10
12.7
F i e l d
Page 75
MS 2204 Specifications
MS 2204 2D Decode Distances Table 5-4. MS 2204 2D Slab/Raster Decode Distances Symbol Density/ Symbol p/n / Bar Code Type
Bar Code Content/ Contrast1
Typical Working Ranges3 Near
Far
Guaranteed Working Ranges3 Near
Far
6.6 mil 64-14035-01 PDF417
ABCDEF 80% MRD
1.5 in. 3.81 cm
6.00 in. 15.24 cm
Note 2
4.75 in. 12.07 cm
10 mil 64-14937-01 PDF417
012345678905 35% MRD
3.5 in. 8.89 cm
8.0 in. 20.32 cm
Note 2
5.0 in. 12.7 cm
10 mil 64-14037-01 PDF417
80% MRD
3.5 in. 8.89 cm
9.0 in. 22.86 cm
Note 2
7.5 in. 19.05 cm
15 mil 64-14038-01 PDF417
80% MRD
5.6 in. 14.22 cm
15.0 in. 38.10 cm
Note 2
13.0 in. 33.02 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 10°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C.
Note: Not optimized for omnidirectional mode.
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge acuity. Consider width of decode zone at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-12 describes how to calculate the usable scan length.
5-11
Page 76
MS XX04 Integration Guide
5-12