Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 33

MiniScan MS XX04 Series Integration Guide: Chapter 2 Installation, pages 36 to 44

Pages 36 to 44 of 310, from MiniScan MS XX04 Series Integration Guide

The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204

Page 36

MS XX04 Series Integration Guide

Male jack shown for reference

Insertion Direction

1

1 2 3

2 3 Note: Due to many variations of jack and socket styles, identify terminals as shown before soldering leads.

11 -- Ground Ground(Sleeve) (Sleeve) 22 -- Battery Vcc (Middle Contact) (Middle Contact) 33 -- Trigger Trigger(Tip) (Tip)

Figure 2-8. Trigger Jack Connector Pins

2-10

Page 37

Installation

Location and Positioning Caution The location and positioning guidelines provided do not consider unique application characteristics. It is recommended that an opto-mechanical engineer perform an opto-mechanical analysis prior to integration. Note: Integrate the scanner in an environment no more extreme than the product’s specification, where the scanner will not exceed its temperature range. For instance, do not mount the scanner onto or next to a large heat source. When placing the scanner with another device, ensure there is proper convection or venting for heat. Follow these suggestions to ensure product longevity, warranty, and overall satisfaction with the scanner.

Using the MiniScan as an Embedded Scanner The MiniScan can be mounted to read symbols that are automatically presented, or that are presented in a pre-determined location. In these applications, MinScan positioning with respect to the symbol is critical. Failure to properly position the MiniScan can result in unsatisfactory scanning performance. A thermal analysis is also recommended. Two methods of positioning the scanner are provided: •

•

Use the Calculating the Usable Scan Length Method on page 2-12 with consistently good quality symbols. This provides a mathematical solution to find the usable scan length. The Testing the Usable Scan Length Method on page 2-13 uses real situation testing to adjust the usable scan length to fit the application conditions.

2-11

Page 38

MS XX04 Series Integration Guide

Calculating the Usable Scan Length Method Calculate usable scan length as follows (see Figure 2-9 on page 2-13): L = 1.8 x (D+d+B) x Tan (A/2) Table 2-1. Calculation Constants Constants

B

A

MS 1204FZY (Default)

1.17

42°

MS 1204FZY (Narrow Mode)

1.17

30°

MS 2204

1.53

34°

MS 2204VHD

1.53

34°

MS 3204

1.93

34°

MS 804FZY

0.89

46.5°

MS 804FZY (Narrow Mode)

0.89

35°

MS 904HS

0.77

37° where: D = Distance (in inches) from the front edge of the host housing to the bar code. d = The host housing’s internal optical path from the edge of the housing to the front of the MiniScan scanner. B = Internal optical path from the scan mirror to the front edge of the MiniScan scanner. A = Scan angle in degrees. Note: Usable scan length determined by this formula, or 90% of scan line at any working distance. This formula is based on good quality symbols in the center of the working range and length of bar code.

2-12

Page 39

Installation

Bar Code Host System

1/2 L MiniScan

L

A

1/2 L B d

D

Figure 2-9. Usable Scan Length Diagram

Testing the Usable Scan Length Method Due to the variety of symbol sizes, densities, print quality, etc., there is no simple way to calculate the ideal symbol distance. To optimize performance, use the Testing The Usable Scan Length positioning method: 1. Measure the maximum and minimum distances at which the symbols can be read. 2. Check the near and far range on several symbols. If they are not reasonably consistent there may be a printing quality problem that can degrade the performance of the system. Symbol Technologies can provide advice on how to improve the installation. Note: Poor quality symbols (from bad printing, wear, or damage) may not decode well when placed in the center of the depth of field (especially higher density codes). The scan beam has a minimum width in the central area, and when the scanner tries to read all symbol imperfections in this area it may not decode. After a preliminary spot is determined using good quality symbols, test several reduced quality symbols and adjust the spot for the best overall symbol position. 3. Locate the scanner so the symbol is near the middle of the near/far range.

2-13

Page 40

MS XX04 Series Integration Guide

4. Center the symbol (left to right) in the scan line whenever possible. 5. Position the symbol so that the scan line is as near as possible to perpendicular to the bars and spaces in the symbol. 6. Avoid specular reflection (glare) off the symbol by tilting the top or bottom of the symbol away from the scanner. The exact angle is not critical, but it must be large enough so that if a mirror were inserted in the symbol location, the reflected scan line would miss the front surface of the scanner. For the maximum allowable angles refer to the Skew, Pitch and Roll angles listed in each MiniScan Technical Specifications table. 7. If an additional window is to be placed between the scanner and the symbol, determine the optimum symbol location using a representative window in the desired window position. 8. Give the scanner time to dwell on the symbol for several scans. When first enabled, the MiniScan may take two or three scans before it reaches maximum performance. Enable the MiniScan before the symbol is presented, if possible.

Conveyor Applications Conveyor applications require setting the conveyor velocity to optimize the scanner’s ability to read symbols. Also consider the orientation of the symbol with respect to the conveyor direction. Figure 2-10 on page 2-15 illustrates the relationship of the conveyor velocity with respect to a symbol positioned perpendicular to the conveyor direction and Figure 2-11 on page 2-16 illustrates the relationship of the conveyor velocity with respect to a symbol positioned parallel to the conveyor direction.

2-14

Page 41

Installation

Symbol is Perpendicular to Conveyor Movement With the symbol bars perpendicular to the conveyor belt direction (Picket Fence presentation) the relationship is:

V = (R x (F-W)) / N where:

V = Velocity of the conveyor (inches/second) R = Scan Rate (see technical specifications) F = 80% of width of scan beam W = Symbol Width (inches) N = Number of scans over symbol (minimum of 10 scans) F=Field Width W=Sy mbol W idth

Directi on of C onvey or Per

Scan Beam pendic ular to

Symb ol

Figure 2-10. Symbol Perpendicular To Conveyor Movement

Example R = 640 scans per second F = 80% of 6 in. W = 4 in. N = 10 V = (640 x ((0.8 x 6) - 4))) / 10 = 51.2 in./sec

2-15

Page 42

MS XX04 Series Integration Guide

Symbol is Parallel to Conveyor Movement With the symbol bars parallel to the conveyor belt direction (ladder presentation) the relationship is:

V = (R x H) / N where:

V = Velocity of the conveyor (inches/second) R = Scan Rate of scanner (see technical specifications) H = Symbol height N = Number of scans over symbol (minimum of 10 scans)

ght

H=Symbol Hei

Scan Beam lel to onveyor Paral

Direction of C

Symbol

Figure 2-11. Symbol Parallel To Conveyor Movement

Example Use the previous formula to calculate the number of scans for a specific bar code, scanner, and conveyor speed; a minimum of 10 scans per symbol is recommended. R = 640 scans/sec H = 60 mil N = 10 scans V = (640 x .060) / 10 = 3.84 in./sec

2-16

Page 43

Installation

Accessories The following accessories are available for the MiniScan scanner, and can be found in Symbol’s Solution Builder (ordering guide). •

•

•

•

•

For power connection - 110V power supply, US, p/n 50-14000-008 - 220V power supply, Europe, p/n 50-14000-009 - 100V power supply, Asia, p/n 50-14000-010 - 264V Universal power supply (also order cables below), p/n 50-14001-001 - DC line cord (power supply to scanner), p/n 50-16002-009 - AC line cord (wall outlet to power supply), p/n 23844-00-00 RS-232 - Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and no beeper, p/n 25-13227-XX - Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and beeper, p/n 25-13228-XX - Female DB9 with straight connector to RS-232 host (female DB9), p/n 25-58918-XX - Female DB9 with right angle connector to RS-232 host (female DB9), p/n 25-58919-XX - Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and no hardware handshaking, p/n 25-63736-XX Cable Adapters - Female 25 pin D, TxD on pin 2, p/n 50-12100-378 - Female 25 pin D, TxD on pin 3, p/n 50-12100-377 - Male 25 pin D, TxD on pin 2, p/n 50-12100-380 - Male 25 pin D, TxD on pin 3, p/n 50-12100-379 Optional Accessories - Push button trigger cable, p/n 25-04950-XX - Photo sensor trigger cable, p/n 25-13176-XX - Fixed-mount stand, p/n 20-60136-XX - Mounting bracket, p/n KT-65578-01 Software - Software Developer's CD, p/n SW-60371-XX

2-17

Page 44

MS XX04 Series Integration Guide

Software Developer’s CD The Software Developer’s CD provides the software tools required to integrate and communicate with the MiniScan scanners, including: •

Sample Windows® program with source code

•

DLL with source code for building user applications

•

ActiveX component (including help file) for easy integration into VisualBasic programs

•

Simple Serial Interface documentation.

With over 70 programmable parameters, MiniScan scanners can be configured by scanning bar code menus, or through the serial interface using Symbol’s Simple Serial Interface protocol. For Windows®, DOS, and embedded system environments, the CD enables the user to take full advantage of the scanner’s features and obtain maximum performance.

2-18