Page 251

Parameter Menus

Parameter Event Parameter # F0h 03h When enabled, the scanner sends a message to the host when one of the events specified in Table 11-3 on page 11-126 occurs. When disabled, no message is sent.

Enable (01h)

*Disable (00h)

11-129

Page 252

MS XX04 Series Integration Guide

Macro PDF Features Note: These options are supported by the MS 2204, MS 2204VHD and MS 3204 only.

Transmit Symbols in Codeword Format Parameter # Afh Enable this to transmit each PDF symbol as directly decoded data codewords, whether or not that symbol is part of a macro PDF sequence. Note that data is output as codeword values, not as interpreted data. “Codeword values” is an ASCII representation of a number from 000 to 928 for each codeword, preceded by an escape character. This escape character is a backslash by default, but you can change this value. For example, the codeword value 005 is sent to the host in the form of \005 for GLIs, and \C005C for ECIs. This output format is based on the AIM USA Uniform Symbology Specification for PDF417 (1994). All output codewords are exactly 4 characters for GLIs and 6 characters for ECIs. However, there can be non-decodable characters in the PDF symbol, such as a GLI sequence. This special codeword sequence activates a certain kind of interpretation to the encoded data. Non-decodable codewords like GLIs are embedded in the output stream like any other codeword, e.g., \927\001. Because GLIs are indistinguishable from other codewords in the output data stream, the host must recognize them as GLIs and process their interpretations. Note that when a macro PDF sequence is transmitted, the last character in the last block of data transmitted is always \922 (if selected). This indicates the end of that macro PDF transmission.

11-130

Page 253

Parameter Menus

Transmit Symbols in Codeword Format (Continued) Scan the appropriate bar code to enable or disable this.

Enable Transmit In Codeword Format (01h)

*Disable Transmit In Codeword Format (00h)

11-131

Page 254

MS XX04 Series Integration Guide

Transmit Unknown Codewords Parameter # BAh Select Transmit Unknown Codewords to use the output codeword format for transmitting any non-GLI or non-macro PDF codeword. Select Do Not Transmit Unknown Codewords to sound a decode error beep when an unknown codeword is found.

Transmit Unknown Codewords (01h)

*Do Not Transmit Unknown Codewords (00h)

11-132

Page 255

Parameter Menus

Escape Characters Parameter # E9h This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data (e.g., GLI escapes, MacroPDF417 Control Block optional fields) according to the GLI (Global Label Identifier) protocol or the ECI (Extended Channel Interpretation) protocol, or to disable this parameter.

ECI Protocol (01h)

GLI Protocol (02h)

*None (00h)

11-133

Page 256

MS XX04 Series Integration Guide

Delete Character Set ECIs Parameter # E6h Note: This option is supported by the MS 2204, MS 2204VHD and MS 3204 only. Select Delete Character Set ECIs to delete any escape sequences representing Character Set ECIs (also known as GLIs) from its buffer before transmission. In many receiving systems, Character Set ECIs can be removed without affecting the way data is displayed or processed. Select Transmit Character Set ECIs to transmit data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. Scan a bar code to delete or transmit character set ECIs.

Delete Character Set ECIs (01h)

*Transmit Character Set ECIs (00h)

11-134

Page 257

Parameter Menus

ECI Decoder Parameter # E8h Note: This option is supported by the MS 2204, MS 2204VHD and MS 3204 only. This parameter enables the scanner to interpret any Extended Channel Interpretations (ECIs) that are supported by the scanner firmware. This does not affect symbols not encoded using ECIs. This version of the product supports ECIs 000900 through 000913, used for efficient encoding of Common Data Syntax Format 00-99. If this parameter is disabled, and a symbol is scanned that was encoded using an ECI escape, the scanner transmits the ECI escape followed by the uninterpreted data. Scan a bar code to enable or disable this option.

*Enable ECI Decoder (01h)

Disable ECI Decoder (00h)

11-135

Page 258

MS XX04 Series Integration Guide

Transmit Macro PDF User-Selected Fields Note: These options are supported by the MS 2204, MS 2204VHD and MS 3204 only. Enable or disable each of the following parameters to indicate whether or not to transmit the specified field in subsequently scanned Macro PDF417 symbols. The options cannot be changed in the middle of a Macro PDF set entry. All user-selected fields are prefixed by \923 for GLIs, and \C923C for ECIs. Tags and examples in the following parameters demonstrate GLI protocol, but the ECI tag (\C923C) can be used instead if ECI protocol is enabled.

11-136

Page 259

Parameter Menus

Transmit File Name Parameter # B0h Transmit File Name activates transmission of the file name field. The field character tag is \923\000. For example, the filename MANHOURS.WK1 is sent as: \923\000MANHOURS.WK1.

Enable File Name Transmit (01h)

*Disable File Name Transmit (00h)

11-137

Page 260

MS XX04 Series Integration Guide

Transmit Block Count Parameter # B1h Transmit Block Count activates transmission of the block count field. The field character tag is \923\001. For example, the field may be: \923\0011856.

Enable Transmit Block Count (01h)

*Disable Transmit Block Count (00h)

11-138