The text of a manual · part 27 of 33
MiniScan MS XX04 Series Integration Guide, pages 251 to 260
Pages 251 to 260 of 310
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 251
Parameter Menus
Parameter Event Parameter # F0h 03h When enabled, the scanner sends a message to the host when one of the events specified in Table 11-3 on page 11-126 occurs. When disabled, no message is sent.
Enable (01h)
*Disable (00h)
11-129
Page 252
MS XX04 Series Integration Guide
Macro PDF Features Note: These options are supported by the MS 2204, MS 2204VHD and MS 3204 only.
Transmit Symbols in Codeword Format Parameter # Afh Enable this to transmit each PDF symbol as directly decoded data codewords, whether or not that symbol is part of a macro PDF sequence. Note that data is output as codeword values, not as interpreted data. “Codeword values” is an ASCII representation of a number from 000 to 928 for each codeword, preceded by an escape character. This escape character is a backslash by default, but you can change this value. For example, the codeword value 005 is sent to the host in the form of \005 for GLIs, and \C005C for ECIs. This output format is based on the AIM USA Uniform Symbology Specification for PDF417 (1994). All output codewords are exactly 4 characters for GLIs and 6 characters for ECIs. However, there can be non-decodable characters in the PDF symbol, such as a GLI sequence. This special codeword sequence activates a certain kind of interpretation to the encoded data. Non-decodable codewords like GLIs are embedded in the output stream like any other codeword, e.g., \927\001. Because GLIs are indistinguishable from other codewords in the output data stream, the host must recognize them as GLIs and process their interpretations. Note that when a macro PDF sequence is transmitted, the last character in the last block of data transmitted is always \922 (if selected). This indicates the end of that macro PDF transmission.
11-130
Page 253
Parameter Menus
Transmit Symbols in Codeword Format (Continued) Scan the appropriate bar code to enable or disable this.
Enable Transmit In Codeword Format (01h)
*Disable Transmit In Codeword Format (00h)
11-131
Page 254
MS XX04 Series Integration Guide
Transmit Unknown Codewords Parameter # BAh Select Transmit Unknown Codewords to use the output codeword format for transmitting any non-GLI or non-macro PDF codeword. Select Do Not Transmit Unknown Codewords to sound a decode error beep when an unknown codeword is found.
Transmit Unknown Codewords (01h)
*Do Not Transmit Unknown Codewords (00h)
11-132
Page 255
Parameter Menus
Escape Characters Parameter # E9h This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data (e.g., GLI escapes, MacroPDF417 Control Block optional fields) according to the GLI (Global Label Identifier) protocol or the ECI (Extended Channel Interpretation) protocol, or to disable this parameter.
ECI Protocol (01h)
GLI Protocol (02h)
*None (00h)
11-133
Page 256
MS XX04 Series Integration Guide
Delete Character Set ECIs Parameter # E6h Note: This option is supported by the MS 2204, MS 2204VHD and MS 3204 only. Select Delete Character Set ECIs to delete any escape sequences representing Character Set ECIs (also known as GLIs) from its buffer before transmission. In many receiving systems, Character Set ECIs can be removed without affecting the way data is displayed or processed. Select Transmit Character Set ECIs to transmit data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. Scan a bar code to delete or transmit character set ECIs.
Delete Character Set ECIs (01h)
*Transmit Character Set ECIs (00h)
11-134
Page 257
Parameter Menus
ECI Decoder Parameter # E8h Note: This option is supported by the MS 2204, MS 2204VHD and MS 3204 only. This parameter enables the scanner to interpret any Extended Channel Interpretations (ECIs) that are supported by the scanner firmware. This does not affect symbols not encoded using ECIs. This version of the product supports ECIs 000900 through 000913, used for efficient encoding of Common Data Syntax Format 00-99. If this parameter is disabled, and a symbol is scanned that was encoded using an ECI escape, the scanner transmits the ECI escape followed by the uninterpreted data. Scan a bar code to enable or disable this option.
*Enable ECI Decoder (01h)
Disable ECI Decoder (00h)
11-135
Page 258
MS XX04 Series Integration Guide
Transmit Macro PDF User-Selected Fields Note: These options are supported by the MS 2204, MS 2204VHD and MS 3204 only. Enable or disable each of the following parameters to indicate whether or not to transmit the specified field in subsequently scanned Macro PDF417 symbols. The options cannot be changed in the middle of a Macro PDF set entry. All user-selected fields are prefixed by \923 for GLIs, and \C923C for ECIs. Tags and examples in the following parameters demonstrate GLI protocol, but the ECI tag (\C923C) can be used instead if ECI protocol is enabled.
11-136
Page 259
Parameter Menus
Transmit File Name Parameter # B0h Transmit File Name activates transmission of the file name field. The field character tag is \923\000. For example, the filename MANHOURS.WK1 is sent as: \923\000MANHOURS.WK1.
Enable File Name Transmit (01h)
*Disable File Name Transmit (00h)
11-137
Page 260
MS XX04 Series Integration Guide
Transmit Block Count Parameter # B1h Transmit Block Count activates transmission of the block count field. The field character tag is \923\001. For example, the field may be: \923\0011856.
Enable Transmit Block Count (01h)
*Disable Transmit Block Count (00h)
11-138