Page 231

Parameter Menus

Data Options Transmit Code ID Character Parameter # 2Dh A code ID character identifies the code type of a scanned bar code. This can be useful when decoding more than one code type. The code ID character is inserted between the prefix character (if selected) and the decoded symbol. Select no code ID character, a Symbol Code ID character, or an AIM Code ID character. The Symbol Code ID characters are listed below. Table 11-2. Symbol Code ID Characters Code Type

Symbol Identifier

UPC-A, UPC-E, UPC-E1, EAN-13, EAN-8

A

Code 39, Code 32

B

Codabar

C

Code 128, ISBT 128

D

Code 93

E

Interleaved 2 of 5

F

Discrete 2 of 5, D 2of 5 IATA

G

Code 11

H

MSI Plessey

J

UCC/EAN 128

K

Bookland EAN

L

Trioptic Code 39

M

Coupon Code

N

RSS (all variants)

R

Composite*

T

Scanlet

W

*Note: UPC/EAN Composite is transmitted in two portions, each with a "T" prefix.

11-109

Page 232

MS XX04 Series Integration Guide

Transmit Code ID Character (continued)

Symbol Code ID Character (02h)

AIM Code ID Character (01h)

*None (00h)

11-110

Page 233

Parameter Menus

Prefix/Suffix Values Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes; see Numeric Bar Codes beginning on page 11-146) that corresponds to that value. See Table A-1 on page A-1 for the four-digit codes. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11-148. Note: In order to use Prefix/Suffix values, first set the Scan Data Transmission Format. See page 11-113.

11-111

Page 234

MS XX04 Series Integration Guide

Prefix/Suffix Values (continued)

Scan Prefix (07h)

Scan Suffix 1 (06h)

Scan Suffix 2 (08h)

Data Format Cancel

11-112

Page 235

Parameter Menus

Scan Data Transmission Format Parameter # EBh To change the scan data format, scan one of the following eight bar codes corresponding to the desired format. Note: To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 11-111.

*Data As Is (00h)

<DATA> <SUFFIX 1> (01h)

<DATA> <SUFFIX 2> (02h)

<DATA> <SUFFIX 1> <SUFFIX 2> (03h)

11-113

Page 236

MS XX04 Series Integration Guide

Scan Data Transmission Format (continued)

<PREFIX> <DATA > (04h)

<PREFIX> <DATA> <SUFFIX 1> (05h)

<PREFIX> <DATA> <SUFFIX 2> (06h)

<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)

11-114

Page 237

Parameter Menus

Simple Serial Interface (SSI) Options Baud Rate Parameter # 9Ch Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Baud Rate 300 (01h)

Baud Rate 600 (02h)

Baud Rate 1200 (03h)

Baud Rate 2400 (04h)

11-115

Page 238

MS XX04 Series Integration Guide

Baud Rate (continued)

Baud Rate 4800 (05h)

*Baud Rate 9600 (06h)

Baud Rate 19,200 (07h)

38,400 (08h)

11-116

Page 239

Parameter Menus

Parity Parameter # 9Eh A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. If you select Odd parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits is contained in the coded character.

Odd (00h)

If you select Even parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits is contained in the coded character.

Even (01h)

11-117

Page 240

MS XX04 Series Integration Guide

Parity (continued) Select Mark parity and the parity bit is always 1.

Mark (02h)

Select Space parity and the parity bit is always 0.

Space (03h)

If no parity is required, select None.

*None (04h)