The text of a manual · part 22 of 33
MiniScan MS XX04 Series Integration Guide, pages 201 to 210
Pages 201 to 210 of 310
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 201
Parameter Menus
Length Within Range - Select this option to decode only codes within a specified range. For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11-148.
I 2 of 5 - Length Within Range
Any Length - Scan this option to decode I 2 of 5 symbols containing any number of characters. Note: Selecting this option can lead to misdecodes for I 2 of 5 codes.
I 2 of 5 - Any Length
11-79
Page 202
MS XX04 Series Integration Guide
I 2 of 5 Check Digit Verification Parameter # 31h When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).
*Disable (00h)
USS Check Digit (01h)
OPCC Check Digit (02h)
11-80
Page 203
Parameter Menus
Transmit I 2 of 5 Check Digit Parameter # 2Ch Scan this symbol to transmit the check digit with the data.
Transmit I 2 of 5 Check Digit (Enable) (01h)
Scan this symbol to transmit data without the check digit.
*Do Not Transmit I 2 of 5 Check Digit (Disable) (00h)
11-81
Page 204
MS XX04 Series Integration Guide
Convert I 2 of 5 to EAN-13 Parameter # 52h This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. To accomplish this, I 2 of 5 must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
Convert I 2 of 5 to EAN-13 (Enable) (01h)
*Do Not Convert I 2 of 5 to EAN-13 (Disable) (00h)
11-82
Page 205
Parameter Menus
Discrete 2 of 5 Enable/Disable Discrete 2 of 5 Parameter # 05h To enable or disable Discrete 2 of 5, scan the appropriate bar code below.
Enable Discrete 2 of 5 (01h)
*Disable Discrete 2 of 5 (00h)
11-83
Page 206
MS XX04 Series Integration Guide
Set Lengths for Discrete 2 of 5 Parameter # L1 = 14h, L2 = 15h The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. Lengths for D 2 of 5 can be set for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select D 2 of 5 One Discrete Length, then scan 1, 4, to decode only D 2 of 5 symbols containing 14 characters. Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11148.
*D 2 of 5 - One Discrete Length
Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, to decode only D 2 of 5 symbols containing 2 or 14 characters. Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11-148.
D 2 of 5 - Two Discrete Lengths
11-84
Page 207
Parameter Menus
Length Within Range - Select this option to decode codes within a specified range. For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must be preceded by a leading zero). Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11-148.
D 2 of 5 - Length Within Range
Any Length - Scan this option to decode D 2 of 5 symbols containing any number of characters. Note: Selecting this option can lead to misdecodes for D 2 of 5 codes.
D 2 of 5 - Any Length
11-85
Page 208
MS XX04 Series Integration Guide
Codabar Enable/Disable Codabar Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below.
Enable Codabar (01h)
*Disable Codabar (00h)
11-86
Page 209
Parameter Menus
Set Lengths for Codabar Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters) the code contains, including start or stop characters. Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select Codabar One Discrete Length, then scan 1, 4, to decode only Codabar symbols containing 14 characters. Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11148.
Codabar - One Discrete Length
Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, to decode only Codabar symbols containing 2 or 14 characters. Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11-148.
Codabar - Two Discrete Lengths
11-87
Page 210
MS XX04 Series Integration Guide
Length Within Range - Select this option to decode a code within a specified range. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 11-146. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 11148.
*Codabar - Length Within Range
Any Length - Scan this option to decode Codabar symbols containing any number of characters.
Codabar - Any Length
11-88