Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 6

MDM 3006 Modem Module Quick Reference, pages 4 to 9

Pages 4 to 9 of 32: MDM 3006 Connectors; Connecting to the Phone Line; Configuring for Palm OS

The original document is the PDF (266 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MDM-3006

Page 4

M D M M o d e m

3 0 0 6 M o d u l e

MDM 3006 Connectors RJ-11 Phone Jack Battery Charger Connector

Attaching and Removing the MDM 3006 To attach the MDM 3006 to your terminal, place it at the bottom of the terminal as shown, and press the terminal into place. To remove, pull the terminal from the MDM 3006. While the MDM 3006 is attached, you cannot: • • use a cradle for battery charging or communication use the RS-232 serial port on the bottom of the terminal.

Charging the Terminal’s Battery To charge the terminal’s battery with the MDM 3006 attached, you need a power supply and a line cord. Note:

Use only a Symbol-approved power supply (p/n 5014000-107) output rated 9VDC and minimum 2A. The power supply is certified to EN60950 with SELV outputs.

Hinweis:Benutzen Sie nur eine Symbol Technologies genehmigt Stromversorgung (p/n 50-14000-107) in den Ausgabe: 9VDC und minimum 2A. Die Stromversorgung ist bescheinigt nach EN60950 mit SELV Ausgaben. 2

Page 5

Q u i c k

R e f e r e n c e

To charge the terminal’s battery:

Line Cord

Power Supply

The terminal’s battery is fully charged after two hours, if terminal is off. You can continue to use the terminal while it is plugged into the wall outlet.

Connecting to the Phone Line To dial in to a remote host computer using the MDM 3006, you will need an RJ-11 cable. To connect this cable: 1. Insert the RJ-11 cable into the RJ-11 phone jack on the MDM 3006. 2. Connect the other end of the cable into an analog telephone jack on the wall.

3

Page 6

M D M M o d e m

Caution:

3 0 0 6 M o d u l e

To reduce the risk of fire, use only No. 26 AWG or larger RJ-11 cable.

Using the Correct Telephone Line Type Use a standard analog phone line. In an office, use a line connected to a fax machine or modem. In a hotel, request a room with a standard phone line. If necessary, check with the local phone company or administrator to ensure you’re using the right type of line before connecting to the modem.

Configuring for Palm OS Note:

Modem drivers for Palm OS version 3.2 and 3.5 are available at http://devzone.symbol.com. The drivers enable power to the modem through the terminal's serial port. For OS version 3.2, use PowerDrv32.prc; for version 3.5, use PowerDrv35.prc. Use HotSync to load the driver onto the terminal, and then perform a soft reset.

Host Computer Setup To use the MDM 3006 to synchronize with your network, Palm Desktop Software must be installed and an external modem must be attached to the host computer's COM port. 1. Install Palm Desktop Software on your host computer. Download the latest version from www.palm.com/support. Refer to the instructions included with the software you download.

4

Page 7

Q u i c k

R e f e r e n c e

2. Start Palm Desktop and configure the HotSync Manager for modem connections. Refer to the instructions included with software you download.

Modem Requirements • • • • • • a terminal an MDM 3006 modem telephone number from your dial-in server administrator a dial-in account on the host system, including a user ID and password a RJ11 or RJ12 modem cable a functioning telephone jack that supports plug-in modems connected to the local telephone system.

Terminal Setup To define modem connection settings: 1. Tap the Applications icon in the Graffiti area to display the Applications Launcher screen. 2. Tap the Prefs icon to display the Preferences screen. 3. Tap the triangle in the upper right corner of the screen to display a menu and select Connection. 4. Tap New... to create a new connection, or select Custom from Available Configuration drop-down menu and tap Edit.... 5. Enter a name for the connection in the Name: text box.

5

Page 8

M D M M o d e m

3 0 0 6 M o d u l e

6. Select PwrCradle to Modem from the Connection Method drop-down menu. 7. Select TouchTone from the Dialing drop-down menu. Note:

Do not select Rotary unless you are sure your telephone service does not support Touch Tone dialing.

8. Select Off from the Volume drop-down menu (there is no speaker in this modem). 9. Tap the Details... button to select speed and flow control. 10. Select 57,600 bps from the Speed drop-down menu for best performance. 11. Select Automatic from the Flow Ctl drop-down menu for the modem connection. 12. If necessary, edit the Init String: text box to set country parameters. The modem defaults to operation with US telephone networks. To operate the modem with other country telephone networks, you must set the appropriate country code. See Modem Country Setup on page 19. 13. Tap the OK button until you return to the Preferences screen shown in step 2 on page 5. To prepare your terminal for a modem HotSync operation: 1. Tap the Applications icon in the Graffiti area to display the Applications Launcher screen.

6

Page 9

Q u i c k

R e f e r e n c e

2. Tap the HotSync icon. 3. Tab Modem on the HotSync screen.

4. Tap the Menu icon in the Graffiti area and select Modem Sync Prefs... from the Options menu. 5. Tap Direct to modem. 6. Tap the OK button. 7. Tap the Enter phone # button to open the Phone Setup screen. 8. Enter the telephone number required to access the modem connected to your host computer in the Phone #: text box. 9. If necessary, select the Dial Prefix: check box and enter a dial prefix (such as “9”) to access an outside line. A comma can be used to insert a “pause” in the dialing sequence. 10. If your phone line has call waiting, select the Disable call waiting: check box and enter a code to avoid an interruption during the modem HotSync operation. 11. If you want to use a calling card to place the call, select the Use calling card: check box and enter the calling card number.

7