Chapter 7 Maintenance & Troubleshooting Introduction This chapter includes instructions on cleaning and storing the mobile computer, and provides troubleshooting solutions for potential problems during mobile computer operation.

Maintaining the Mobile Computer For trouble-free service, observe the following tips when using the mobile computer:

• Protect the mobile computer from temperature extremes. Do not leave it on the dashboard of a car on a hot day, and keep it away from heat sources.

• Do not store or use the mobile computer in any location that is extremely dusty, damp, or wet. • Use a soft lens cloth to clean the mobile computer. If the surface of the mobile computer screen becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution.

• Periodically replace the rechargeable Li-ion battery to ensure maximum battery life and product performance. Battery life depends on individual usage patterns.

• Take care not to scratch the screen of the mobile computer. When working with the mobile computer, use the supplied stylus or plastic-tipped pens intended for use with a touch-sensitive screen. Never use an actual pen or pencil or other sharp object on the surface of the mobile computer screen.

• The touch-sensitive screen of the mobile computer contains glass. Take care not to drop the mobile computer or subject it to strong impact.

Battery Safety Guidelines • The area in which the units are charged should be clear of debris and combustible materials or chemicals. Particular care should be taken where the device is charged in a non-commercial environment.

• Do not use incompatible batteries and chargers. If you have any questions about the compatibility of a battery or a charger, contact Motorola Enterprise Mobility support. See Service Information on page xii for contact information.

Page 196

7-2

MC909X Mobile Computer User Guide

• Do not crush, puncture, or place a high degree of pressure on the battery. • Severe impact from dropping any battery-operated device on a hard surface could cause the battery to overheat.

• Do not leave or store the equipment in or near areas that might get very hot, such as in a parked vehicle or near a radiator or other heat source. Do not place battery into a microwave oven or dryer.

• Do not dispose of batteries in fire. • If you suspect damage to your equipment or battery, call Motorola Enterprise Mobility support to arrange for inspection. See Service Information on page xii for contact information.

Page 197

Maintenance & Troubleshooting

7-3

Troubleshooting Mobile Computer Table 7-1 Troubleshooting the Mobile Computer

Problem

Cause

Solution

Mobile computer does not turn on.

Lithium-ion battery not charged.

Charge or replace the lithium-ion battery in the mobile computer.

Lithium-ion battery not installed properly.

Ensure battery is installed properly. See Installing and Removing the Main Battery on page 1-6.

System crash.

Perform a warm boot. If the mobile computer still does not turn on, perform a cold boot. See Resetting the Mobile Computer on page 2-49.

Battery failed.

Replace battery. If the mobile computer still does not operate, try a warm boot, then a cold boot. See Resetting the Mobile Computer on page 2-49.

Mobile computer removed from cradle while battery was charging.

Insert mobile computer in cradle and begin charging. The lithium-ion battery requires less than four hours to recharge fully.

Cannot see characters on display.

Mobile computer not powered on.

Press the Power button.

During data communication, no data was transmitted, or transmitted data was incomplete.

Mobile computer removed from cradle or unplugged from host computer during communication.

Replace the mobile computer in the cradle, or reattach the Synchronization cable and re-transmit.

Incorrect cable configuration.

See the System Administrator.

Communication software was incorrectly installed or configured.

Perform setup. Refer to the MC909X Integrator Guide for details.

Volume setting is low or turned off.

Adjust volume.

Rechargeable lithium-ion battery did not charge.

No sound is audible.

Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Page 198

7-4

MC909X Mobile Computer User Guide

Table 7-1 Troubleshooting the Mobile Computer (Continued)

Problem

Cause

Solution

Mobile computer turns itself off.

Mobile computer is inactive.

The mobile computer turns off after a period of inactivity. If the mobile computer is running on battery power, this period can be set to 30 sec., 1, 2, 3, 4, 5 or 6 minutes. If the mobile computer is running on external power, this period can be set to 1, 2, 3, 5, 10, 15 and 30 minutes. For Windows Mobile 5.0 devices, Check the power settings by tapping Start > Settings > System tab > Power icon > Advanced tab. For Windows CE 5.0 devices, Check the power settings by tapping Start > Settings > Control Panel > Power icon > Power Off tab. Change the setting if you need a longer delay before the automatic shutoff feature activates.

Battery is depleted.

Replace the battery.

Battery is not inserted properly.

Insert the battery properly (see Installing and Removing the Main Battery on page 1-6).

Tapping the window buttons or icons does not activate the corresponding feature.

LCD screen not aligned correctly.

Re-calibrate the screen.

The system is hung.

Warm boot the system. To perform a warm boot (see Resetting the Mobile Computer on page 2-49).

A message appears stating that the mobile computer memory is full.

Too many files stored on the mobile computer.

Delete unused memos and records. You can save these records on the host computer.

Too many applications installed on the mobile computer.

If you have installed additional applications on the mobile computer, remove them to recover memory. For Windows Mobile 5.0 devices, tap Start > Settings > System tab > Remove Programs icon. For Windows CE 5.0 devices, tap Start > Settings > Control Panel > Remove Programs icon. Select the unused program and tap Remove.

Page 199

Maintenance & Troubleshooting

7-5

Table 7-1 Troubleshooting the Mobile Computer (Continued)

Problem

Cause

Solution

The mobile computer does not accept scan input.

Scanning application is not loaded.

Verify that the unit is loaded with a scanning application. See the System Administrator.

Unreadable bar code.

Ensure the symbol is not defaced.

Distance between exit window and bar code is incorrect.

Ensure mobile computer is within proper scanning range.

Mobile computer is not programmed for the bar code.

Ensure the mobile computer is programmed to accept the type of bar code being scanned.

Mobile computer is not programmed to generate a beep.

If a beep on a good decode is expected and a beep is not heard, check that the application is set to generate a beep on good decode.

Battery is low.

If the scanner stops emitting a laser beam when the trigger is pressed, check the battery level. When the battery is low, the scanner shuts off before the mobile computer low battery condition notification. Note: If the scanner is still not reading symbols, contact the distributor or Symbol Technologies.

Microsoft security feature prevents connection to two separate networks.

Disconnect from the WLAN or WWAN network prior to connecting to a host computer using ActiveSync.

WLAN or WWAN connection is lost when the mobile computer is connected to a host computer using ActiveSync.

Bluetooth Connection Table 7-2 Troubleshooting Bluetooth Connection

Problem Mobile computer cannot find any Bluetooth devices nearby.

Cause

Solution

Too far from other Bluetooth devices.

Move closer to the other Bluetooth device(s), within a range of 10 meters.

The Bluetooth device(s) nearby are not turned on.

Turn on the Bluetooth device(s) you wish to find.

The Bluetooth device(s) are not in discoverable mode.

Set the Bluetooth device(s) to discoverable mode. If needed, refer to the device’s user documentation for help.

Page 200

7-6

MC909X Mobile Computer User Guide

Table 7-2 Troubleshooting Bluetooth Connection (Continued)

Problem

Cause

Solution

Mobile computer keeps powering down to protect memory contents.

The mobile computer’s battery is low.

Recharge the battery.

When trying to connect a Bluetooth phone and mobile computer, the phone thinks a different mobile computer (that I previously paired with the phone) is used.

The phone remembers the name and address of the mobile computer it last paired with via the Bluetooth radio.

Manually delete the pairing device and name from the phone. Refer to the phone’s user documentation for instructions.

There is a delay during a resume from suspend.

This is the normal behavior.

No solution required.

Four Slot Charge Only Cradle Table 7-3 Troubleshooting the Four Slot Charge Only Cradle

Problem Mobile computer charge indicator LED does not light.

Cause

Solution

Cradle is not receiving power.

Ensure the power supply is securely connected and receiving power.

Mobile computer is not seated correctly in the cradle.

Ensure the battery is properly installed in the mobile computer, and re-seat the mobile computer in the cradle.

The battery is not properly installed in the mobile computer. The battery in the mobile computer is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Note: The Four Slot Charge Only Cradle has no power indication.

Page 201

Maintenance & Troubleshooting

7-7

Four Slot Ethernet Cradle Table 7-4 Troubleshooting the Four Slot Ethernet Cradle

Symptom

Cause

Solution

Attempt by the mobile computer to ActiveSync failed.

Mobile computer removed from the cradle while the LED was blinking green.

Wait one minute and reinsert the mobile computer in the cradle. This allows the cradle to attempt another synchronization.

ActiveSync on the host computer has not yet closed the previous ActiveSync session.

Wait one minute and reinsert the mobile computer in the cradle. This allows the cradle to attempt another synchronization.

Incorrect cable configuration.

Check your DHCP server and determine which IP address was allocated to the cradle, then check connectivity by pinging the cradle.

Communications software improperly configured.

Perform setup as described in the MC909X Integrator Guide. Check your DHCP server and determine which IP address was allocated to the mobile computer slot, then check connectivity by pinging the cradle.

Mobile computer ActiveSync disabled or not configured to accept network connection.

For Windows Mobile 5.0 devices, tap Start > Programs > ActiveSync icon > Menu > Connections. Uncheck the Synchronize all PCs using this connection: check box.

During communications, no data was transmitted, or transmitted data was incomplete.

For Windows CE 5.0 devices, tap Start > Settings > Control Panel > PC Connections icon. Uncheck the Enable direct connections to the desktop computer check box.

Host ActiveSync disabled or not configured to accept network connection.

On the host computer, check File > Connection Settings > Allow network (Ethernet) Server Connection with this desktop computer.

Mobile computer removed from cradle during communications.

Replace mobile computer in cradle and retransmit.

Mobile computer has no active connection.

An icon will be visible in the status bar if a connection is currently active.

Communication software was incorrectly installed or configured.

Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Page 202

7-8

MC909X Mobile Computer User Guide

Table 7-4 Troubleshooting the Four Slot Ethernet Cradle (Continued)

Symptom

Cause

Solution

Mobile computer has successfully connected through the cradle, but no data is being transmitted over the connection.

Data is being transferred over the S24 radio link.

Temporarily disable the radio link to force data transmission through the cradle. Tap the wireless LAN icon from the systray. Enter an in-valid value in the ESSID: text box and tap the OK button. Power cycle the mobile computer. Verify that your radio link has been disabled (the wireless LAN icon has a red box with an “!” on it). Once you have completed your data transmission, re-enable your radio link.

All Communication Status LEDs are flashing red.

The unit could not configure itself, or it has lost the lease on its IP address.

Connect the unit to an Ethernet network with a correctly functioning DHCP server.

Failed automatic cradle configuration via local DHCP service.

Connect a properly configured DHCP server or DHCP relay agent to the subnet, and power cycle the cradle. Check the DHCP server log to verify that the cradle is receiving a response to its DHCP request.

The Ethernet link may be down.

Ensure the ethernet cable is connected to an active hub.

Mobile computer has been inserted incorrectly into the cradle.

Remove, wait a minute, and then reinsert the mobile computer, ensuring it fits snugly onto the connector at the bottom of the cradle.

Cradle is not receiving power.

Ensure the power supply is securely connected and receiving power.

Communication Status LED does not light up.

Page 203

Maintenance & Troubleshooting

7-9

Table 7-4 Troubleshooting the Four Slot Ethernet Cradle (Continued)

Symptom

Cause

Battery is not recharging.

Warning Message - “! Unable to obtain a server assigned IP address. Try again later or enter an IP address in Network Settings.”

Solution

Mobile computer removed from the cradle too soon.

Replace the mobile computer into the cradle. It can take up to four hours to recharge a completely depleted battery pack if mobile computer is suspended or longer if the mobile computer is on. For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Mobile computer is not inserted correctly into the cradle.

Remove the mobile computer and reinsert it correctly. Verify charging is active. For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

This message occurs if a suspend/resume cycle is performed and the mobile computer radio is not associated (e.g. due to being out of range)

Tap OK to close the message. The mobile computer will obtain address information and communicate through the Ethernet cradle.

Four Slot Spare Battery Charger Table 7-5 Troubleshooting The Four Slot Spare Battery Charger

Symptom Batteries not charging.

Possible Cause

Solution

Battery was removed from the charger or charger was unplugged from AC power too soon.

Ensure MSR is receiving power. Ensure mobile computer is attached correctly. Confirm main battery is charging. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge a battery (if the mobile computer is off and longer if the mobile computer is operating). For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Battery contacts not connected to charger.

Verify that the battery is seated in the battery well correctly with the contacts facing down.

Page 204

7 - 10 MC909X Mobile Computer User Guide

Single Slot Serial/USB Cradle Table 7-6 Troubleshooting the Single Slot Serial/USB Cradle

Symptom

Possible Cause

Solution

LEDs do not light when mobile computer or spare battery is inserted.

Cradle is not receiving power.

Ensure the power cable is connected securely to both the cradle and to AC power.

Mobile computer is not seated firmly in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is firmly seated.

Spare battery is not seated firmly in the cradle.

Remove and re-insert the spare battery into the charging slot, ensuring it is firmly seated.

Mobile computer was removed from cradle or cradle was unplugged from AC power too soon.

Ensure cradle is receiving power. Ensure mobile computer is seated correctly. Confirm main battery is charging. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge a battery (if the mobile computer is off and longer if the mobile computer is operating). For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

The mobile computer is not fully seated in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is firmly seated.

Battery not fully seated in charging slot.

Remove and re-insert the spare battery into the cradle, ensuring it is firmly seated.

Battery inserted incorrectly.

Ensure the contacts are facing down and toward the back of the cradle.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Mobile computer removed from cradle during communications.

Replace mobile computer in cradle and retransmit.

Incorrect cable configuration.

See the System Administrator.

Communications software is not installed or configured properly.

Perform setup as described in the MC909X Integrator Guide.

Mobile computer battery is not charging.

Spare battery is not charging.

During data communications, no data was transmitted, or transmitted data was incomplete.

Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Page 205

Maintenance & Troubleshooting 7 - 11

Cable Adapter Module Table 7-7 Troubleshooting The Cable Adapter Module

Symptom

Possible Cause

Solution

Mobile computer battery is not charging.

Mobile computer was removed from CAM or CAM was unplugged from AC power too soon.

Ensure CAM is receiving power. Ensure mobile computer is attached correctly. Confirm main battery is charging. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge a battery (if the mobile computer is off and longer if the mobile computer is operating). For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

The mobile computer is not fully attached to the CAM.

Detach and re-attach the CAM to the mobile computer, ensuring it is firmly connected.

Mobile computer detached from CAM during communications.

Re-attach mobile computer to CAM and retransmit.

Incorrect cable configuration.

See the System Administrator.

Communications software is not installed or configured properly.

Perform setup as described in the MC909X Integrator Guide.

During data communications, no data was transmitted, or transmitted data was incomplete.

Ensure that Microsoft ActiveSync 4.1 or greater is installed on the host computer.

Magnetic Stripe Reader Table 7-8 Troubleshooting the Magnetic Stripe Reader

Symptom

Possible Cause

Solution

MSR cannot read card.

Mobile computer detached from MSR during card swipe.

Re-attach mobile computer to MSR and reswipe the card.

Faulty magnetic stripe on card.

See the System Administrator.

MSR application is not installed or configured properly.

Ensure the MSR application is installed on the mobile computer. Ensure the MSR application is configured correctly.

Page 206

7 - 12 MC909X Mobile Computer User Guide

Table 7-8 Troubleshooting the Magnetic Stripe Reader (Continued)

Symptom

Possible Cause

Solution

Mobile computer battery is not charging.

Mobile computer was removed from MSR or MSR was unplugged from AC power too soon.

Ensure MSR is receiving power. Ensure mobile computer is attached correctly. Confirm main battery is charging. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge a battery (if the mobile computer is off and longer if the mobile computer is operating). For Windows Mobile 5.0 devices, view battery status by tapping Start > Settings > System tab > Power icon. For Windows CE 5.0 devices, view battery status by tapping Start > Settings > Control Panel > Power icon.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

The mobile computer is not fully attached to the MSR.

Detach and re-attach the MSR to the mobile computer, ensuring it is firmly connected.

Mobile computer detached from MSR during communications.

Reattach mobile computer to MSR and retransmit.

Incorrect cable configuration.

See the System Administrator.

Communications software is not installed or configured properly.

Perform setup as described in the MC909X Integrator Guide.

During data communications, no data was transmitted, or transmitted data was incomplete.

Page 207

Maintenance & Troubleshooting 7 - 13

Modem Module Table 7-9 Troubleshooting the Modem Module

Symptom

Possible Cause

Mobile computer is not communicating through the modem.

The modem cable is not fully connected.

Connect the modem cable securely to both the modem and the telephone jack.

Modem is not securely connected to the mobile computer.

Reconnect the modem firmly to the mobile computer.

Communication software is not installed or configured properly.

Set up the communication software as described in the MC909X Integrator Guide.

Problem in the telephone lines.

Connect a conventional telephone and dial the remote modem to verify the telephone lines are functioning. If the remote modem does not answer the call and emit answering tones, contact the remote System Administrator.

Mobile computer’s battery is low or discharged, which shuts off power to the modem.

Install a charged battery in the MC909X, or use an external DC power adapter to recharge the battery.

A partnership was not established with the host computer.

Establish a partnership with the host computer (refer to the MC909X Integrator Guide).

Host computer is not selected in the ActiveSync window on the mobile computer.

Select a host computer in the ActiveSync window, and perform setup (refer to the MC909X Integrator Guide).

Mobile computer or modem was disconnected from the telephone line while ActiveSync was in progress.

Disconnect the modem cable for 30 seconds to hang up the local telephone connection. Close any open windows on the mobile computer and any modem connections.

ActiveSync fails.

Solution

Page 208

7 - 14 MC909X Mobile Computer User Guide

Table 7-9 Troubleshooting the Modem Module (Continued)

Symptom Dial-out fails

Possible Cause

Solution

Location setting is incorrect.

Verify Dialing Locations. Verify Dialing Patterns are correct for the current location. For example, enter ‘G’ in the For local calls, dial: field to dial directly, or ‘9,G’ if the telephone system requires dialing ‘9’ first to access an outside line.

Incorrect server phone number.

Verify the connection phone number in the Connecting window.

Pulse dialing not supported for country.

Use a connection within a tone-dialing system.

Dialtone detection not supported.

The service you subscribe to (e.g., a remote answering service) may use a different type of dialtone. Disable dialtone detection on the modem by entering the initialization string “ATXO” in the Extra dial-string modem commands: text box of the Modem Settings window.

The Connection Manager routes are incorrect.

Warm boot the mobile computer and confirm the connection settings.