Page 129
Chapter 6
Maintenance & Troubleshooting
Chapter 6 Maintenance & Troubleshooting
Introduction This chapter includes instructions on cleaning and storing the EDA, and provides troubleshooting solutions for potential problems during EDA operation.
Maintaining the EDA For trouble-free service, observe the following tips when using the EDA: •
Do not scratch the screen of the EDA. When working with the EDA, use the supplied stylus or plastic-tipped pens intended for use with a touch-sensitive screen. Never use an actual pen or pencil or other sharp object on the surface of the EDA screen. Symbol recommends using a screen protector, p/n KT-67525-01.
•
The touch-sensitive screen of the EDA is glass. Do not to drop the EDA or subject it to strong impact.
•
Protect the EDA from temperature extremes. Do not leave it on the dashboard of a car on a hot day, and keep it away from heat sources.
•
Do not store or use the EDA in any location that is dusty, damp, or wet.
•
Use a soft lens cloth to clean the EDA. If the surface of the EDA screen becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution.
•
Periodically replace the rechargeable battery to ensure maximum battery life and product performance. Battery life depends on individual usage patterns.
•
A screen protector is applied to the EDA. Symbol recommends using this to minimize wear and tear. Screen protectors enhance the usability and durability of touch screen displays. Benefits include:
- Protection from scratches and gouges - Durable writing and touch surface with tactile feel - Abrasion and chemical resistance - Glare reduction - Keeping the device’s screen looking new - Quick and easy installation.
Page 130
6-2
MC70 User Guide
Troubleshooting EDA Table 6-1 Troubleshooting the EDA Problem
Cause
EDA does not turn on.
Lithium-ion battery not charged.
Charge or replace the lithium-ion battery in the EDA.
Lithium-ion battery not installed properly.
Install the battery properly. See Installing and Removing the Main Battery on page 1-4.
System crash.
Perform a warm boot. If the EDA still does not turn on, perform a cold boot. See Resetting the EDA on page 2-24.
Battery failed.
Replace battery. If the EDA still does not operate, perform a warm boot, then a cold boot. See Resetting the EDA on page 2-24.
EDA removed from cradle while battery was charging.
Insert EDA in cradle. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours.
Cannot see characters on display.
EDA not powered on.
Press the Power button.
During data communication, no data transmitted, or transmitted data was incomplete.
EDA removed from cradle or disconnected from host computer during communication.
Replace the EDA in the cradle, or reattach the communication cable and re-transmit.
Incorrect cable configuration.
See the system administrator.
Communication software was incorrectly installed or configured.
Perform setup. Refer to the MC70 Integrator Guide for details.
No sound.
Volume setting is low or turned off.
Adjust the volume. See Speaker Icon on page 2-3.
EDA shuts off.
EDA is inactive.
The EDA turns off after a period of inactivity. If the EDA is running on battery power, set this period from 1 to 5 minutes, in one-minute intervals. If the EDA is running on external power, set this period to 1, 2, 5, 10, 15, or 30 minutes. Check the Power window by selecting Start - Settings - System tab and tapping the Power icon. Select the Advanced tab and change the setting for a longer delay before the automatic shutoff feature activates.
Battery is depleted.
Replace the battery.
Battery is not inserted properly.
Insert the battery properly. See Installing and Removing the Main Battery on page 1-4.
Rechargeable lithium-ion battery did not charge.
Solution
Page 131
Maintenance & Troubleshooting
6-3
Table 6-1 Troubleshooting the EDA (Continued) Problem
Cause
Solution
Tapping the window buttons or icons does not activate the corresponding feature.
Screen is not calibrated correctly.
Re-calibrate the screen. See Calibrating the Screen on page 1-8.
The system is not responding.
Warm boot the system. See Resetting the EDA on page 2-24.
Too many files stored on the EDA.
Delete unused memos and records. If necessary, save these records on the host computer (or use an SD card for additional memory).
Too many applications installed on the EDA.
Remove user-installed applications on the EDA to recover memory. Select Start - Settings - System tab and tap the Remove Programs icon. Select the unused program and tap Remove.
EDA keeps powering down to protect memory contents.
The EDA’s battery is low.
Recharge the battery.
The radio is powered on for a long time.
Because this mode requires battery power, power it off when not needed. Using the SetDeviceState() API (refer to the SMDK Help File), set the Bluetooth to D4 power state.
The EDA does not accept scan input.
Scanning application is not loaded.
Load a scanning application on the EDA. See the system administrator.
Unreadable bar code.
Ensure the symbol is not defaced.
Distance between exit window and bar code is incorrect.
Place the EDA within proper scanning range.
EDA is not programmed for the bar code.
Program the EDA to accept the type of bar code being scanned.
EDA is not programmed to generate a beep.
If the EDA does not beep on a good decode, set the application to generate a beep on good decode.
Battery is low.
If the scanner stops emitting a laser beam upon a trigger press, check the battery level. When the battery is low, the scanner shuts off before the EDA low battery condition notification. Note: If the scanner is still not reading symbols, contact the distributor or Symbol Technologies.
A message appears stating that the EDA memory is full.
Page 132
6-4
MC70 User Guide
Bluetooth Connection Table 6-2 Troubleshooting Bluetooth Connection Problem
EDA cannot find any Bluetooth devices nearby.
Cause
Solution
Too far from other Bluetooth devices.
Move closer to the other Bluetooth device(s), within a range of 10 meters.
The Bluetooth device(s) nearby are not turned on.
Turn on the Bluetooth device(s) to find.
The Bluetooth device(s) are not in discoverable mode.
Set the Bluetooth device(s) to discoverable mode. If needed, refer to the device’s user documentation for help.
When trying to connect a Bluetooth phone and EDA, the phone thinks a previously paired EDA is used.
The phone remembers the name and address of the EDA it last paired with via the Bluetooth radio.
Manually delete the pairing device and name from the phone. Refer to the phone’s user documentation for instructions.
Can’t make my Ericsson R520 phone discoverable.
You attempted to bond with the phone, and when the phone presented a “pairing query,” you entered No. This prevents the phone from being discoverable until it is reset.
Reset the phone by removing its battery.
There is a delay in the Bluetooth stack re-initializing during a resume from suspend.
This is normal behavior.
No solution required.
Page 133
Maintenance & Troubleshooting
6-5
Table 6-2 Troubleshooting Bluetooth Connection (Continued) Problem
Cause
Solution
Piconet (the connection between a Bluetooth master and one or more Bluetooth slaves) drops.
The EDA suspends and the Bluetooth radio power turns off.
An application can register for notification of an EDA resume by creating a message queue using the CreateMsgQueue() API and power notifications using the RequestPowerNotifications() API (refer to the SMDK Help File). After an application receives a resume notification it should close open Bluetooth sessions and reopen them.This reestablishes the piconet lost during the suspend.
My application created a successful RFCOMM session with another Bluetooth device but the session was dropped.
Device went out of range or was shut off.
Check the return value of APIs for errors. Look for a DCD state change event in the Microsoft Bluetooth stack DCD window of the Bluetooth connection.
After completing an RFCOMM session with another Bluetooth device, I was unable to create a virtual COM port to connect to another Bluetooth device.
The Microsoft Bluetooth stack holds a baseband connection for ten seconds after an application closes its session and exits. This was designed to allow for speedy connections to the same device if other profiles were to connect.
Either wait 10 seconds, choose a different COM port number for the virtual COM port, or modify HKLM\software\Microsoft\bluetooth\l2cap\IdlePhys (which defines the number of seconds to hold the connection).
One of the devices are out of range.
Page 134
6-6
MC70 User Guide
Single Slot USB/Serial Cradle Table 6-3 Troubleshooting the Single Slot USB/Serial Cradle Symptom
Possible Cause
Action
LEDs do not light when EDA or spare battery is inserted.
Cradle is not receiving power.
Ensure the power cable is connected securely to both the cradle and to AC power.
EDA is not seated firmly in the cradle.
Remove and re-insert the EDA into the cradle, ensuring it is firmly seated.
Spare battery is not seated firmly in the cradle.
Remove and re-insert the spare battery into the charging slot, ensuring it is firmly seated.
EDA was removed from cradle or cradle was unplugged from AC power too soon.
Ensure cradle is receiving power. Ensure EDA is seated correctly. Confirm main battery is charging under Start - Settings - System Power. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The EDA is not fully seated in the cradle.
Remove and re-insert the EDA into the cradle, ensuring it is firmly seated.
Ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 0oC and 35oC.
Battery not fully seated in charging slot.
Remove and re-insert the spare battery in the cradle, ensuring it is firmly seated.
Battery inserted incorrectly.
Re-insert the battery so the charging contacts on the battery align with the contacts on the cradle.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
Ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 0oC and 35oC.
EDA removed from cradle during communications.
Replace EDA in cradle and retransmit.
Incorrect cable configuration.
See the system administrator.
Communication software is not installed or configured properly.
Perform setup as described in the MC70 Integrator Guide.
EDA battery is not charging.
Spare battery is not charging.
During data communication, no data transmits, or transmitted data was incomplete.
Page 135
Maintenance & Troubleshooting
6-7
Four Slot Ethernet Cradle Table 6-4 Troubleshooting the Four Slot Ethernet Cradle Symptom
Cause
Solution
Attempt by the EDA to ActiveSync failed.
EDA removed from the cradle while the LED was blinking green.
Wait one minute and reinsert the EDA in the cradle. This allows the cradle to attempt another synchronization.
Using an outdated version of ActiveSync.
Visit http://www.microsoft.com for the latest ActiveSync software.
ActiveSync on the host computer has not yet closed the previous ActiveSync session.
Wait one minute and reinsert the EDA in the cradle. This allows the cradle to attempt another synchronization.
Incorrect cable configuration.
Ensure the correct cable (Ethernet) is used with the cradle.
Communication software improperly configured.
Perform setup as described in the MC70 Integrator Guide.
EDA ActiveSync disabled or not configured to accept network connection.
On the EDA, tap Start - ActiveSync - Tools - Options - Options button. Then, uncheck the Enable PC sync using this connection: check box.
Host ActiveSync disabled or not configured to accept network connection.
On the host computer, check File - Connection Settings - Allow network (Ethernet) Server Connection with this desktop computer.
During communication, no data transmits, or transmitted data was incomplete.
EDA removed from cradle during communications.
Replace EDA in cradle and retransmit.
EDA has no active connection.
An icon is visible in the status bar if a connection is currently active.
Battery is not charging.
EDA removed from the cradle too soon.
Replace the EDA in the cradle. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours. Tap Start - Settings - System - Power to view battery status.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
EDA is not inserted correctly in the cradle.
Remove the EDA and reinsert it correctly. Verify charging is active. Tap Start - Settings - System - Power to view battery status.
Ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 0oC and 35oC.
Page 136
6-8
MC70 User Guide
Vehicle Cradle Table 6-5 Troubleshooting the Vehicle Cradle Symptom
Possible Cause
Action
EDA battery charging LED does not light up.
Cradle is not receiving power.
Ensure the power input cable is securely connected to the cradle’s power port.
EDA battery is not recharging.
EDA was removed from the cradle too soon.
Replace the EDA in the cradle. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours.
Battery is faulty.
Replace the battery.
EDA is not placed correctly in the cradle.
Remove the EDA from the cradle, and re-insert correctly. If the battery still does not charge, contact customer support. The EDA battery charging LED slowly blinks amber when the EDA is correctly inserted and charging.
Ambient temperature of the cradle is too warm.
Move to an area where the ambient temperature is between 0oC and 35oC.
EDA removed from cradle during communication.
Replace EDA in cradle and retransmit.
No null modem cable was used.
Some external devices require a null modem cable. Retransmit using a null modem cable.
Incorrect cable configuration.
See the system administrator.
Cable missing or disconnected.
Re-connect cable.
No data transmitted, or transmitted data was incomplete.
Four Slot Spare Battery Charger Table 6-6 Troubleshooting The Four Slot Spare Battery Charger Symptom
Battery not charging.
Possible Cause
Action
Battery was removed from the charger or charger was unplugged from AC power too soon.
Re-insert the battery in the charger or re-connect the charger’s power supply. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
Battery contacts not connected to charger.
Verify that the battery is seated in the battery well correctly with the contacts facing down.
Ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 0oC and 35oC.
Page 137
Maintenance & Troubleshooting
6-9
Cables Table 6-7 Troubleshooting the Cables Symptom
EDA battery is not charging.
During data communication, no data transmits, or transmitted data was incomplete.
Possible Cause
Action
EDA was disconnected Connect the power cable correctly. Confirm main battery is charging from AC power too soon. under Start - Settings - System - Power. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours. Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The EDA is not fully attached to power.
Detach and re-attach the power cable to the EDA, ensuring it is firmly connected.
Cable was disconnected from EDA during communications.
Re-attach the cable and retransmit.
Incorrect cable configuration.
See the system administrator.
Communication software is not installed or configured properly.
Perform setup as described in the MC70 Integrator Guide.
Magnetic Stripe Reader Table 6-8 Troubleshooting the Magnetic Stripe Reader Symptom
MSR cannot read card.
EDA battery is not charging.
Possible Cause
Action
MSR removed from EDA during card swipe.
Reattach MSR to EDA and reswipe the card.
Faulty magnetic stripe on card.
See the system administrator.
MSR application is not installed or configured properly.
Ensure the MSR application is installed on the EDA. Ensure the MSR application is configured correctly.
EDA was removed from MSR or MSR was unplugged from AC power too soon.
Ensure MSR is receiving power. Ensure EDA is attached correctly. Confirm main battery is charging under Start - Settings - System Power. The standard capacity battery (1900 mAh) fully charges in less than four hours. The extended capacity battery (3800 mAh) fully charges in less than eight hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The EDA is not fully attached to the MSR.
Detach and re-attach the MSR to the EDA, ensuring it is firmly connected.