Page 62

3-10

MC50 Integrator Guide

Magnetic Stripe Reader (MSR) This section describes how to set up and use the snap-on MSR with the mobile computer. The MSR snaps on to the bottom of the mobile computer and can be easily removed when not in use. When attached to the mobile computer, the MSR allows the mobile computer to capture data from magnetic stripe cards. To download MSR data capture software, visit http://devzone.symbol.com.

Attaching and Removing To attach, slide the MSR onto the bottom of the mobile computer and secure by snapping the arms into the mobile computer housing.

Card Reader Slot

Arms

Figure 3-8. MSR Installation To remove the MSR open the arms and pull the MSR from the mobile computer.

Using the MSR The MSR3000 sample application illustrates how an application should handle MSR inputs (refer to Symbol Applications User’s Guide). To use the MSR: 1. Attach the MSR to the mobile computer. 2. Power on the mobile computer. 3. Tap Start - MC50 Demo - Test Apps - MSR MC50 or MSR Cameo to start the sample application.

Page 63

Accessories 3-11

4. Swipe the magnetic stripe card through the MSR, with the magnetic stripe on the card facing down. Swipe the card in either direction, from left to right or from right to left. For best results, gently press down on the card while swiping to ensure contact with the bottom of the reader.

Figure 3-9. Magnetic Stripe Card Swiping

Page 64

3-12

MC50 Integrator Guide

Cable Adapter Module This section describes how to and use the snap-on CAM with the mobile computer. The CAM snaps on to the bottom of the mobile computer and can be easily removed when not in use.

Communications Port

Power Port

Figure 3-10. Cable Adapter Module When attached to the mobile computer, the CAM: • • •

Provides power for operating the mobile computer, with the appropriate power connection. Provides USB connection through the USB pass-through port for communication with a USB device, such as a host computer. For communication setup procedures, refer to the MC50 Integrator Guide. Charges the mobile computer’s battery, when used with the appropriate power supply. Use only a Symbol-approved power supply (p/n 50-14000-147) output rated 5.4 Vdc and minimum 3A. The power supply is certified to EN60950 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous. Hinweis: Benutzen Sie nur eine von Symbol Technologies genehmigte Stromversorgung (Teilenr. 50-14000-147) mit einer Ausgangsleistung von 5.4 V (Gleichstrom) und mindestens 3A. Die Stromversorgung ist nach EN60950 für die Verwendung in SELV-Stromkreisen zertifiziert. Bei Verwendung eines anderen Netzteils werden alle für das Gerät gewährten Genehmigungen außer Kraft gesetzt, und der Betrieb kann gefährlich sein.

Attaching and Removing To attach, slide the CAM onto the bottom of the mobile computer, until it snaps into place.

Figure 3-11. CAM Installation To remove the CAM pull the CAM from the mobile computer.

Page 65

Accessories 3-13

Remove the CAM from the bottom of the mobile computer before using a cradle for charging and communication.

Battery Charging To charge the mobile computer’s battery through the CAM, attach the CAM to the mobile computer, then connect the power supply to the CAM. The mobile computer begins charging.

Into Cigarette Lighter

AC Power Supply

Into Cigarette Lighter

Figure 3-12. CAM Power Connection The mobile computer’s charge LED shows the status of the battery charging in the mobile computer. See Table 1-2 on page 1-7 for charging status indications. The standard battery fully charges in approximately 3.5 hours and the extended capacity battery fully charges in approximately seven hours.

USB Connection The CAM can connect to and communicate with a USB device, such as a host computer, through its data port. Refer to the MC50 Integrator Guide for the host computer communication setup procedure. To connect the CAM to a USB device, connect one end of the data cable to the data port on the CAM and the other end to the USB port on the device.

Page 66

3-14

MC50 Integrator Guide

Data Port

To Device USB Port

Figure 3-13. CAM USB Connection

Page 67

Accessories 3-15

Universal Battery Charger (UBC) Adapter This section describes how to use the UBC adapter to charge a spare battery. Use the UBC with a power supply as a standalone spare battery charger, or with the four station UBC2000 to simultaneously charge up to four spare batteries. For additional information about the UBC2000, see the UBC 2000 Universal Battery Charger Product Guide (p/n 70-33188-xx). Use only a Symbol-approved power supply (p/n 50-14000-147) output rated 5.4 Vdc and minimum 3A. The power supply is certified to EN60950 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous. Hinweis: Benutzen Sie nur eine von Symbol Technologies genehmigte Stromversorgung (Teilenr. 50-14000-147) mit einer Ausgangsleistung von 5.4 V (Gleichstrom) und mindestens 3A. Die Stromversorgung ist nach EN60950 für die Verwendung in SELV-Stromkreisen zertifiziert. Bei Verwendung eines anderen Netzteils werden alle für das Gerät gewährten Genehmigungen außer Kraft gesetzt, und der Betrieb kann gefährlich sein.

Battery Insertion and Removal Insert the battery into the battery well with the charging contacts on the battery aligning with the charging pins on the adapter, and gently press down on the battery to ensure proper contact. To remove the battery, press the battery release and lift battery out of the well. Battery

Battery Well

)

llow )

REA (Gre DY en

CH A (Sol RGIN id Ye G

Battery Release or S TA (Flas ND B hing Yello Y or w) FA (Flas ULT hin g Ye llow )

UBC Adapter

POWER

READY (Green)

CHARGING or STANDBY or FAULT (Solid Yellow)

(Flashing Yellow)

(Flashing Yellow)

Figure 3-14. UBC Adapter

Battery Charging Indicators To charge a spare battery using the UBC adapter, insert the spare battery. The spare battery begins charging.

Page 68

3-16

MC50 Integrator Guide

The UBC’s charge LEDs show the status of the battery charging in the adapter. Table 3-3 shows battery charging status indications. The standard battery fully charges in approximately 2.5 hours and the extended capacity battery fully charges in approximately six hours.

POWER

READY (Green)

CHARGING or STANDBY or FAULT (Solid Yellow)

(Flashing Yellow)

(Flashing Yellow)

Figure 3-15. UBC Adapter LEDs

Table 3-3. UBC Adapter Charge LED Status Indications LED

Indication

Description

POWER

Red

Power is connected to the UBC Adapter.

READY

Green

Charging complete.

CHARGING or STANDBY or FAULT

Yellow

Normal charge.

Flashing Yellow

The battery was deeply discharged and is being trickle charged to bring the voltage up to the operating level. After operating level voltage is achieved the battery charges normally.

Flashing Yellow

Charging error, check placement of mobile computer/spare battery.

Page 69

Accessories 3-17

Page 70

3-18

MC50 Integrator Guide