Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 9

MC3090Z RFID Mobile Computer Integrator Guide: RFID Sample Application

Pages 31 to 44 of 62, from MC3090Z RFID Mobile Computer Integrator Guide

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MC3090-Z

Page 31

Chapter 4 RFID Sample Application Introduction Application developers can use the RFID sample application RFIDSample3Plus.exe for an overview of how the application works and to assist in custom application development. The mobile computer can read, write, lock, kill, and program Gen2 tags. Each tag contains the EPC number (64 or 96 bits), CRC, and kill code. The mobile computer can also collect data by decoding in-range EPC Gen2 RFID tags. Initiating the read command within the sample application causes the mobile computer to interrogate all RFID tags within the radio frequency (RF) field of view. The reader captures data from each new tag and adds it to the list box in the EPC ID window. Select Stop Read to stop interrogating tags.

Page 32

4-2

MC3090Z RFID Mobile Computer Integrator Guide

Launching the RFID Sample Application Remove the mobile computer from AC power and enable LLRP, then use File Explorer on the mobile computer to navigate to the Application folder. Select RFIDSample3Plus.exe to start the sample application.

Figure 4-1 RFID Sample Application Window NOTE The version numbers displayed in this window are examples. Actual version numbers are based on the versions of the files on the device.

• Tap Menu to select the menu options. See Sample Application Menu Options on page 4-3. • Tap the Start Read button to initiate the tag read. Tap Stop Read to terminate tag reading. See Reading Tags on page 4-14.

• Use the Mem Bank drop-down to select a tag memory bank to read. The default memory bank is EPC (None). Other options are TID, Reserved, and User.

• Tap the note icon to generate an audio notification (beep) when the reader finds a new tag in the field of view.

Page 33

RFID Sample Application

Sample Application Menu Options The Menu options include:

• Configuration options • Operations options • Reader management options • About

Figure 4-2 Sample Application Menu

Configuration Menu Options The Config menu includes the following options:

• Connection information • Configuration options • Capabilities • Reset Factory defaults • Exit

Figure 4-3 Configuration Menu

4-3

Page 34

4-4

MC3090Z RFID Mobile Computer Integrator Guide

Connection Select Config > Connection to display the reader IP and port number.

Figure 4-4 Connection Window

Select Disconnect to disconnect the reader.

Antenna Select Config > Configuration > Antenna to configure the antenna.

Figure 4-5 Antenna Configuration Window

This window includes the following fields:

• Antenna - Selecting an antenna ID updates the configuration values in the other fields. • Receive Sensitivity(dB) - Lists the reader-supported values for the selected antenna. • Transmit Power - Lists the reader-supported values for the selected antenna. • Hop Index - Updates the Hop Frequency list with its corresponding frequencies. • Apply - Select to apply the configuration changes.

Page 35

RFID Sample Application

4-5

Singulation Select Config > Configuration > Singulation to set the options for identifying an individual tag in a multiple-tag environment.

Figure 4-6 Singulation Window

This window includes the following fields:

• Antenna - Selecting an antenna ID updates the configuration values in the other fields. • Session - The session number for the inventory operation. • Tag Transmit Time - The time in milliseconds that the tag typically remains in the RF field of the antenna. • Tag Population - The approximate tag population in the RF field of the antenna. • Inventory State - Select a tag of state A or B. • SL Flag • Apply - Select to apply the configuration changes.

Capabilities Select Config > Capabilities to retrieve the capabilities of the connected reader.

Figure 4-7 Capabilities Window

Select OK to close the window.

Page 36

4-6

MC3090Z RFID Mobile Computer Integrator Guide

Reset Factory Defaults Select Config > Reset Factory Defaults to restore the default reader configuration.

Operations Menu Options The Operations menu options include:

• Tag Storage Settings • Filter options • Access options • Trigger settings • Antenna information

Figure 4-8 Operations Menu

Tag Storage Settings Select Operations > Tag Storage Settings to change the tag storage settings.

Figure 4-9 Tag Storage Window

This window includes the following fields:

• Max tag count - The maximum number of tags to store in the DLL. • Max tag ID length - The maximum tag length.

Page 37

RFID Sample Application

4-7

• Max size of memory bank - Storage to allocate for the memory bank's data. • Apply - Select to apply the configuration changes.

Filter Settings Use the sample application’s filter settings to set filters for tag reading. The application supports up to two pre-filters and two post-filters. By default, the window displays the latest filter information. Add or delete the filter by selecting Use Filter.

Pre-Filter To select pre-filter settings, select Operations > Filter > Pre-Filter.

Figure 4-10 Pre-Filter Window

This window includes the following fields:

• Antenna - Selecting an antenna ID updates the configuration values in the other fields. • Memory Bank - Select the memory bank. • Offset - The first (msb) bit location of the specified memory bank against which to compare the tag mask. • Tag Mask - The pattern against which to compare the specified memory bank. • Filter action - Select the required filter action. For more information, refer the Gen2 specification available at http://www.epcglobalinc.org/standards/.

Page 38

4-8

MC3090Z RFID Mobile Computer Integrator Guide

Post-Filter To select post-filter settings, select Operations > Filter > Post-Filter.

Figure 4-11 Post Filter Window

This window includes the following fields:

• Match Pattern - Select the tag pattern to match (A, B, both, or neither). • Memory Bank - Select the memory bank. • Offset - The first (msb) bit location of the specified memory bank against which to compare the tag mask. • Bank Data • Tag Mask - The pattern against which to compare the specified memory bank. Access Filter To select filter settings to apply to tags, select Operations > Filter > Access Filter.

Figure 4-12 Post Filter Window

See Post-Filter for descriptions of the window fields.

Page 39

RFID Sample Application

4-9

Access Select Operations > Access to select from a menu of access parameters to set for tags, or tap and hold a tag in the list to open a context menu with similar options in order to set operation parameters for that tag.

Figure 4-13 Access and Context Menus

Selecting an option from the context menu applies the operation to the single tag selected. Selecting an option from the Access menu updates the tag data for multiple tags in the main window. Select an option from the Access or context menu to set access parameters and the access filter.

Figure 4-14 Read and Access Filter Windows

Windows are similar to the Read window in Figure 4-14 for the menu options Write, Lock, Kill, Block Write, and Block Erase. Set options as required in the various parameter windows. Not all windows include all options.

• Tag ID - The name of the selected tag. • Password - Set a password before performing any access operation (except Kill). • Memory Bank - Select the memory bank. Options are: • Reserved • EPC • TID • User

• Offset - Offset of the first word to read from the selected memory bank.

Page 40

4 - 10 MC3090Z RFID Mobile Computer Integrator Guide

• Length - Tag/data length. • Write Data - The data to write to the selected tag (Write window only). • Lock Privilege - Access options for the selected tag (Write window only): • None - The can not change the lock privilege of the particular memory bank. • Read_Write - The user can read and write to the tag. • Perma_Lock - Permanent lock. • Perma_Unlock - Permanent unlock. • Unlock - The user can unlock the tag for writing.

• Access Filter - Select this tab to set access filter parameters. See Post-Filter on page 4-8 for more information.

Triggers Select Operations > Triggers... to set start and stop triggers. Selecting the type of trigger from the Trigger drop-down menu updates the window with that trigger’s applicable parameters.

Figure 4-15 Triggers Window

Antenna Information Select Operations > Antenna Info to select the antennas to use.

Figure 4-16 Antenna Information Window

Page 41

RFID Sample Application 4 - 11

Management Menu Options The Management menu provides access to reader management functionality such as updating firmware, selecting an antenna mode, and rebooting. The Management menu options include:

• Login and Logout options • Reboot option • OEM Update option • Software/Firmware Update option

Figure 4-17 Management Menu

Login/Logout Settings The Reader Management functionality requires login authentication. Select Mgmt > Login/Logout... to log in or out of this functionality.

Figure 4-18 Login Window

This window includes the following fields:

• Reader Type - MC indicates the MC3090Z. • User name - Enter the user name used to gain access to reader management functionality. • Password - Enter the password used to gain access to reader management functionality. • IP - IP address of the host. For MC3090Z, the default is 127.0.0.1 or localhost.

Page 42

4 - 12 MC3090Z RFID Mobile Computer Integrator Guide

Reboot Settings This feature is not supported by handheld readers.

OEM Update Select Mgmt > OEM Update to update the reader configuration file.

Figure 4-19 OEM Update Window

Enter the Path Name indicating the location and name of the configuration file, and select Start Update.

Software/Firmware Update Select Mgmt > Software/Firmware Update to update the reader firmware software.

Figure 4-20 OEM Update Window

Enter the Path Name indicating the location and name of the update file, and select Start Update.

Page 43

RFID Sample Application 4 - 13

About The About window displays the sample application version information

Figure 4-21 About Window NOTE The version numbers displayed in this window are examples. Actual version numbers are based on the versions of the files on the device.

Page 44

4 - 14 MC3090Z RFID Mobile Computer Integrator Guide

Reading Tags To use the sample application to read tags: 1.

Aim the mobile computer at the tag in any orientation (horizontally or vertically). The distance between the tag and the antenna is the approximate read range.

Figure 4-22 RFID Tag Read 2.

Tap Start Read to interrogate all RFID tags within the radio frequency (RF) field of view, and capture data from each new tag found.

Figure 4-23 RFID Tag List

The sample application lists the following information for each tag read:

• EPC ID - The data content of the tag. • RSSI - Received Signal Strength for the tag. • Count - The number of times the mobile computer read the tag. • Data Memory Bank - The memory bank data if you selected Reserved, TID, User, or EPC with offset. • MB - The selected memory bank (TID, RSVD, USER or EPC). Tap Stop Read to stop interrogating tags.