The text of a manual · part 5 of 9
MC3090Z RFID Mobile Computer Integrator Guide: LLRP Functionality
Pages 23 to 30 of 62, from MC3090Z RFID Mobile Computer Integrator Guide
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MC3090-Z
Page 23
Chapter 3 LLRP Functionality Introduction Low Level Reader Protocol (LLRP) is an RFID server application that runs in the background on the mobile computer. The LS icon in the system tray represents LLRP. This chapter includes information on using and configuring the LLRP Server Module.
LLRP Server Icon
Figure 3-1 LLRP Icon
Page 24
3-2
MC3090Z RFID Mobile Computer Integrator Guide
LLRP Icons The LLRP icon indicates radio status as described in Table 3-1. Table 3-1
LLRP Icon Indicators
Icon
Icon State
Indication
Green
LLRP is enabled.
Crossed icon
No radio connection or radio disconnected.
Yellow
Radio is reading at a reduced power level than set due to a cold or degraded battery.
Red
Radio is unable to read, even at a reduced power level, due to a battery condition.
LLRP Menu Tap the LLRP icon to display the option menu shown in Figure 3-2.
Figure 3-2 LLRP Menu
Page 25
LLRP Functionality
Configure Region Upon Startup After upgrading the mobile computer, the following window appears on startup.
Figure 3-3 Country Not Set Window 1.
Tap ok. When no country is selected, the Configure regions settings window appears.
Figure 3-4 Configure Region Settings Window
3-3
Page 26
3-4
MC3090Z RFID Mobile Computer Integrator Guide
2.
Select the region of operation and communication standard as allowed by the regulatory standards of that country/region from the drop-down menus. The following warning message appears.
Figure 3-5 Region Selection Warning Message 3.
Tap Yes to confirm. A window appears indicating success.
Figure 3-6 Region Selection Success Window
Page 27
LLRP Functionality
After Startup If not done at startup, set the regulatory region using the LLRP icon menu: 1.
Tap the LLRP icon, then tap Configure Region.
Figure 3-7 Configure Region Option 2.
Select a region from the Region of Operation drop-down in the following window.
Figure 3-8 Configure Region Settings Window
3-5
Page 28
3-6
MC3090Z RFID Mobile Computer Integrator Guide
3.
Tap Yes on the warning window that appears. A confirmation window appears.
Figure 3-9 Region Selection Success Window 4.
Tap ok.
Page 29
LLRP Functionality
3-7
Configure LLRP LLRP is in Server Mode by default. To configure LLRP to operate in Client Mode: 1.
Tap the LLRP icon, then tap Configure LLRP.
Figure 3-10 LLRP Configuration Window 2.
Select the Client Mode check box.
3.
In the LLRP Port field, enter the port number on which the server waits for the LLRP client to communicate. The default is 5084.
4.
In the Server IP field, enter the server IP for the remote host to which LLRP communicates as a client.
5.
Tap Apply.
6.
Tap ok to close the window.
Version Information To view software version information for the LLRP application, tap the LLRP icon, then tap Version Info.
Figure 3-11 LLRP Versions Window
This window displays the LLRP server application version, RFID library version, radio firmware version, and radio OEM data version. NOTE The version information in Figure 3-11 may differ from the information on the actual mobile computer screen. Also, downloading data using LLRP scripts or the RFID_FLASH application updates the version information.
Page 30
3-8
MC3090Z RFID Mobile Computer Integrator Guide
Exit LLRP Tap the LLRP icon, then tap Exit to close the LLRP application. To restart LLRP after exiting, use File Explorer to browse to the \Application\LLRP folder and tap the LLRP executable (MobileLLRP.exe).
LLRP Registry Entries RFID (LLRP) does not run when the MC3090Z is charging. Developers who require using the cradle with RFID enabled can select Developer Mode by modifying a registry entry.
• User Mode - In this default mode, placing the mobile computer in the cradle (with charging on) disables LLRP and the LLRP icon indicates that it is disconnected. Placing the mobile computer on AC power charges the device and disables LLRP. Removing AC power reconnects LLRP.
• Developer Mode - Selecting Developer Mode disables charging and the developer can place the mobile computer in the cradle for debugging and development. The device remains in Developer Mode regardless of whether it is charging until re-enabling User Mode. To select Developer Mode via registry: 1.
Edit the file params.reg in the \Application folder. To do this, copy the file to the PC, or use a word editor on the mobile computer.
2.
Set the DevMode registry entry value to 1: [HKEY_LOCAL_MACHINE\SOFTWARE\Symbol\RFID\LLRP] "DevMode"=dword:00000001
3.
Tap on the modified file and select Yes to merge the registry.
4.
Warm boot the device by holding down the 7, 9, and Power keys.
5.
Restart LLRP (if it is not already running).
To change back to user mode, repeat this procedure, setting DevMode to 0. LLRP checks AC power every five seconds and takes the appropriate action based on whether or not it is in User Mode.