Page 37

Accessories

2-9

Battery Charging NOTE

To charge the battery for your mobile device, battery and charger temperatures must be between +32° F and +104° F (0° C to +40° C).

The Serial Charge cable and the USB Charge cable can charge the mobile computer’s Li-ion battery. Connect the cables as described above. The mobile computer’s Charge LED blinks amber to indicate that the battery is charging and turns solid amber when the battery is completely charged. The Li-ion battery usually charges in less than four hours. See Table 2-1 on page 2-5 for charging indication information.

Communication Accessories serve as essential data communication devices, enabling the information to be synchronized on the mobile computer with the information on the host device using ActiveSync. The mobile computer can establish communication via serial connection and USB connection with the appropriate software and accessories. Using one of the following accessories:

• Single Slot Serial/USB cradle • Four Slot USB cradle • RS-232 or USB Charging cables. This section provides information on installing the communication software and setting up the appropriate accessory to enable communication between the mobile computer and the host device. For serial communications using the Single Slot Serial/USB cradle, connect only the serial cable, do not connect both the serial cable and the USB cable. If both serial and USB communication cables are required, disable the host computer USB port in ActiveSync before enabling serial communications.

Installing Communication Software To successfully communicate with the host device install Microsoft Activesync (version 3.7 or higher) on the host computer. See Chapter 3, ActiveSync for ActiveSync installation procedures.

Serial Connection Setup 1.

On the mobile computer press F - CTRL - F - ESC to open the Start Menu.

2.

Scroll up to Settings and press ENT. The Control Panel appears.

3.

Scroll to the PC Connections icon and press ENT. The PC Connection window appears.

Page 38

2 - 10 MC1000 with Windows CE 4.2 Integrator Guide

Figure 2-8 PC Connection Window 4.

Press F - TAB to highlight on the Change Connection... button.

5.

Press ENT. The Change Connection window appears.

Figure 2-9 Change Connection Window 6.

Use the scroll up and down keys to select: Serial 3 115200.

7.

Press ENT.

8.

Press F - TAB.

9.

Press ENT to exit the PC Connection window and ENT to exit the Control Panel window.

10. Ensure that ActiveSync is installed on the host computer and a partnership is established. See Setting Up an

ActiveSync Connection on the Host Computer on page 3-2. 11. Start ActiveSync if it is not running on the host computer. To start, select Start - Programs - Microsoft

ActiveSync.

Page 39

Accessories 2 - 11

Figure 2-10 ActiveSync - Not Connected 12. In the ActiveSync window, select File - Connection Settings and ensure the selections shown in Figure 2-11 are made. (Select the appropriate COM port for the host computer.)

Figure 2-11 Serial Connection Settings 13. Click OK to save any changes made. NOTE

Assign each mobile computer a unique device name. Never try to synchronize more than one mobile computer to the same name.

14. Connect the mobile computer to the host computer. See Figure 2-2 to set up a Single Slot Serial/USB cradle, or see Figure 2-7 on page 2-8 to set up a cable. NOTE

The cradle requires a dedicated port. It cannot share a port with an internal modem or other device. Refer to the computer user manual to locate the serial port(s).

15. Upon connection, synchronization occurs automatically.

Page 40

2 - 12 MC1000 with Windows CE 4.2 Integrator Guide

USB Connection Setup 1.

On the mobile computer press F - CTRL - F- ESC to open the Start menu.

2.

Scroll up to Settings and press ENT. The Control Panel appears.

3.

Scroll to the PC Connections icon and press ENT. The PC Connection window appears.

Figure 2-12 PC Connection Window 4.

Press TAB to highlight on the Change Connection... button.

5.

Press ENT. The Change Connection window appears.

Figure 2-13 Change Connection Window 6.

Use the scroll up or down keys to select: USB Default.

7.

Press ENT to exit the Change Connection window.

8.

Press F - TAB.

9.

Press ENT to exit the PC Connection window and ENT to exit the Control Panel window.

Page 41

Accessories 2 - 13

10. Ensure that ActiveSync is installed on the host computer and a partnership is established, see Setting Up an

ActiveSync Connection on the Host Computer on page 3-2. 11. Start ActiveSync if it is not running on the host computer. To start, select Start - Programs - Microsoft

ActiveSync.

Figure 2-14 ActiveSync - Not Connected 12. In the ActiveSync window, select File - Connection Settings and ensure the selections shown in Figure 2-15 are made.

Figure 2-15 USB Connection Settings 13. Click OK to save any changes made. NOTE

Assign each mobile computer a unique device name. Never try to synchronize more than one mobile computer to the same name.

14. Connect the mobile computer to the host computer. See Figure 2-2 on page 2-3 to set up a Single Slot

Serial/USB Cradle, or see Figure 2-7 on page 2-8 to set up a cable. NOTE

The cradle requires a dedicated port. It cannot share a USB port with any other device. Refer to the computer user manual to locate the USB port(s).

Page 42

2 - 14 MC1000 with Windows CE 4.2 Integrator Guide

15. Upon connection, synchronization occurs automatically.

UConnect UConnect software enables automatic synchronization of every mobile computer inserted in the Four-Slot USB cradle.

Installing UConnect To install UConnect via the .CAB file: 1.

Download the UConnect .CAB file from the Support Central website, http://www.symbol.com/support, to the host computer.

2.

Copy the file from the host computer to the mobile computer. See Downloading Files Using ActiveSync on page 5-3.

3.

On the mobile computer, navigate to the .CAB file and run the file.

4.

Follow the screen prompts to install.

With this method, the .CAB file does not install the .cpy and .reg files. Once installed, UConnect launches automatically upon mobile computer startup. Each mobile computer must first form an ActiveSync partnership with a host computer for UConnect to successfully manage synchronization.

Configuring UConnect To customize default settings for UConnect, create a .reg file that overrides UConnect’s initial default settings. Refer to UConnect.reg, included with UConnect, for information on setting custom hard reset and default settings. To customize UConnect temporarily (until the next hard reset): 1.

Switch to the UConnect application.

2.

Using the keypad, navigate to Settings.

Figure 2-16 UConnect Settings Window 3.

Select the Allow UConnect to manage synchronization check box to allow UConnect to control docking events and schedule synchronization sessions. UConnect launches ActiveSync when a mobile computer is inserted in

Page 43

Accessories 2 - 15 the cradle to synchronize the mobile computer and the host computer. If another inserted mobile computer is synchronizing, UConnect reschedules synchronization based on the connection retry interval setting. Deselect this check box to restore control of cradle events to ActiveSync. This may be necessary when temporarily connecting to a non-partnered host computer as a guest. 4.

In the Cancel sync if not connected in text box, enter the maximum time in seconds (between 5 and 120), that UConnect waits for a connection to occur when starting a synchronization session. If UConnect cannot connect to the host computer within this time, it cancels the session and reschedules based on the connection retry interval setting. The default value is 15 seconds.

5.

In the If connection fails retry after text box, enter the number of seconds (between 30 and 9999) that UConnect waits before attempting another synchronization after a failed or lost connection. The default value is 30 seconds.

6.

In the When sync completes, resync after text box, enter the number of minutes (between 10 and 999) that UConnect waits after successful synchronization before scheduling another session. The default value is 15 minutes.

7.

Select the Limit connect time per session to check box to specify the maximum number of minutes that UConnect waits for a synchronization session to complete successfully. Then enter the number of minutes (between 10 and 999) in the text box. The default value is enabled, 30 minutes. If UConnect does not receive a synchronization complete notification from ActiveSync within this time, UConnect disconnects from the host computer to allow recovery in instances where ActiveSync on the host computer or mobile computer cannot complete synchronization.

8.

Select Apply to apply UConnect setting changes. Select Restore to discard UConnect setting changes and return to the previous settings. Select Defaults to restore the default settings. Then select Apply to apply the default settings.

Manually Synchronizing To synchronize a mobile computer immediately without waiting for a scheduled synchronization, select File - Sync Now. Note that this option is not active if the mobile computer is not in the cradle, or if synchronization is already in progress. To exit UConnect and transfer control of docking events and synchronization to ActiveSync, select File - Exit.

UConnect Status To view the status of UConnect events, select View - Status. The Status window displays the following information.

Page 44

2 - 16 MC1000 with Windows CE 4.2 Integrator Guide

Figure 2-17 UConnect Status Window

• The Dock status: field indicates the current docked status of the mobile computer. • The Last sync time: field indicates the date and time the last synchronization session started. If UConnect has not performed synchronization, None appears. Use this field to determine if successful synchronization occurred since the last time the mobile computer was docked.

• The Last sync status: field indicates the status of the most recent or currently active synchronization session. Possible values are: • Successful: The last synchronization session completed successfully. • Waiting for connection: Synchronization started and UConnect is waiting for the connection with the host to complete. • In progress: Synchronization started and UConnect is waiting for a synchronization complete notification from ActiveSync. • Failed: Cable detached: Synchronization failed because the mobile computer is not inserted or the USB cable is detached. • Failed: No connection: UConnect could not establish a connection to the host computer. • Failed: Connection lost: Connection to the host was lost before synchronization completed. • Failed: Connect time exceeded: Synchronization did not complete within the maximum time allowed per session. • Failed: No reason: Synchronization failed for an unknown reason.

• The Next sync time: field indicates the date and time of the next scheduled synchronization session. If UConnect is disabled, the mobile computer is not inserted, or a session is in progress, N/A appears.

• The synchronization history field displays information about docking events and synchronization session status. This field can list up to 100 lines of synchronization history, and can be used to view the status of previous synchronization sessions.

• Select Clear to erase the contents of the synchronization history list box.