Page 87

Chapter 8 Maintenance & Troubleshooting Introduction This chapter includes instructions on cleaning and storing the mobile computer, and provides troubleshooting solutions for potential problems during mobile computer operation.

Maintaining the Mobile Computer For trouble-free service, observe the following tips when using the mobile computer:

• Do not scratch the screen of the mobile computer. When working with the mobile computer, use the supplied stylus or plastic-tipped pens intended for use with a touch-sensitive screen. Never use an actual pen or pencil or other sharp object on the surface of the mobile computer screen.

• Although the mobile computer is water and dust resistant, do not expose it to rain or moisture for an extended period of time. In general, treat the mobile computer as a pocket calculator or other small electronic instrument.

• The screen of the mobile computer is glass. Do not drop the mobile computer or subject it to strong impact. • Protect the mobile computer from temperature extremes. Do not leave it on the dashboard of a car on a hot day, and keep it away from heat sources.

• Do not store or use the mobile computer in any location that is extremely dusty, damp, or wet. • Use a soft lens cloth to clean the mobile computer. If the surface of the mobile computer screen becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution.

Page 88

8-2

MC1000 with Windows CE 4.2 Integrator Guide

Troubleshooting Mobile Computer Table 8-1 Troubleshooting the Mobile Computer

Problem Mobile computer does not turn on.

Cause

Solution

Main battery not charged.

Charge or replace the main battery in the mobile computer.

Main battery not installed properly.

Ensure battery is installed properly. See Main Battery Installation on page 1-3.

System crash.

Perform a warm boot. If the mobile computer still does not turn on, perform a cold boot. See Waking the Mobile Computer on page 1-8.

Battery failed.

Replace battery. If the mobile computer still does not operate, try a warm boot, then a cold boot. See Waking the Mobile Computer on page 1-8.

Mobile computer removed from cradle while battery was charging.

Insert mobile computer in cradle and begin charging. The standard main battery requires up to 4 hours to recharge fully and the extended life main battery requires up to 6 hours to recharge fully.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Cannot see characters on display.

Mobile computer not powered on.

Press the Power button.

During data communication, no data was transmitted, or transmitted data was incomplete.

Mobile computer removed from cradle or unplugged from host computer during communication.

Replace the mobile computer in the cradle, or reattach the cable and re-transmit.

Incorrect cable configuration.

See the system administrator.

Communication software was incorrectly installed or configured.

Perform setup as described in Chapter 3, ActiveSync.

Volume setting is low or turned off.

Adjust volume setting.

Rechargeable main battery did not charge.

Mobile computer does not emit sound.

Page 89

Maintenance & Troubleshooting

8-3

Table 8-1 Troubleshooting the Mobile Computer (Continued)

Problem

Cause

Solution

Mobile computer turns itself off.

Mobile computer is inactive.

The mobile computer turns off after a period of inactivity. This period can be set from 1 to 5 minutes, in one-minute intervals.

Battery is depleted.

Replace the battery.

Battery is not inserted properly.

Insert the battery properly. See Main Battery Installation on page 1-3.

Too many files stored on the mobile computer.

Delete unused memos and records. If necessary, save these records on the host computer.

Too many applications installed on the mobile computer.

Remove unused installed applications from the mobile computer to recover memory.

Scanning application is not loaded.

Verify that the mobile computer is loaded with a scanning application. See the system administrator.

Unreadable bar code.

Ensure the symbol is not defaced.

Distance between exit window and bar code is incorrect.

Ensure mobile computer is within proper scanning range.

Mobile computer is not programmed for the bar code type.

Ensure the mobile computer is programmed to accept the type of bar code scanned.

Mobile computer is not programmed to generate a beep.

Check that the application is set to generate a beep on good decode.

Battery is low.

Check the battery level. When the battery is low, the mobile computer automatically goes into suspend mode.

A message appears stating that the mobile computer memory is full.

The mobile computer does not accept scan input.

Page 90

8-4

MC1000 with Windows CE 4.2 Integrator Guide

Single Slot Serial/USB Cradle Table 8-2 Troubleshooting the Single Slot Serial/USB Cradle

Symptom Charge LEDs do not light when mobile computer or spare battery is inserted. See Figure 2-1 on page 2-2.

Mobile computer battery is not charging.

Spare battery is not charging.

During data communications, no data was transmitted, or transmitted data was incomplete.

Possible Cause

Action

Cradle is not receiving power.

Ensure the power cable is connected securely to both the cradle and to AC power.

Mobile computer is not seated correctly in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is correctly seated.

Spare battery is not seated correctly in the cradle.

Remove and re-insert the spare battery into the charging slot, ensuring it is correctly seated. Note polarity icon on battery.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Mobile computer was removed from cradle or cradle was unplugged from AC power too soon.

Ensure cradle is receiving power. Ensure mobile computer is seated correctly. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge the Li-ion battery.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Mobile computer is not fully seated in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is correctly seated.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Battery not fully seated in charging slot.

Remove and re-insert the spare battery into the cradle, ensuring it is correctly seated. Note polarity icon on battery.

Battery inserted incorrectly.

Ensure the contacts are facing down and toward the back of the cradle. Note polarity icon on battery.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Mobile computer removed from cradle during communications.

Replace mobile computer in cradle and retransmit.

Incorrect cable configuration.

See the system administrator.

Communications software is not installed or configured properly.

Perform setup as described in <Blue><Italic>Communication on page -9.

Page 91

Maintenance & Troubleshooting

8-5

Four Slot USB Cradle Table 8-3 Troubleshooting the Four Slot USB Cradle

Symptom Charge LEDs do not light when mobile computer is inserted. See Figure 2-1 on page 2-2.

Mobile computer battery is not charging.

During data communications, no data was transmitted, or transmitted data was incomplete.

Possible Cause

Action

Cradle is not receiving power.

Ensure the power cable is connected securely to both the cradle and to AC power.

Mobile computer is not seated correctly in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is correctly seated.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Mobile computer was removed from cradle or cradle was unplugged from AC power too soon.

Ensure cradle is receiving power. Ensure mobile computer is seated correctly. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge the Li-ion battery.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Mobile computer is not fully seated in the cradle.

Remove and re-insert the mobile computer into the cradle, ensuring it is correctly seated.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Mobile computer removed from cradle during communications.

Replace mobile computer in cradle and retransmit.

Incorrect cable configuration.

See the system administrator.

Communications software is not installed or configured properly.

Perform setup as described in <Blue><Italic>Communication on page -9.

Page 92

8-6

MC1000 with Windows CE 4.2 Integrator Guide

Cables Table 8-4 Troubleshooting the Cables

Symptom Mobile computer charge LED does not light when mobile computer is connected.

Mobile computer battery is not charging.

During data communication, no data was transmitted, or transmitted data was incomplete.

Possible Cause

Action

Cable is not receiving power.

Ensure the power cable is connected securely to both the cable and to AC power.

Mobile computer is not seated correctly in the cable.

Remove and re-insert the mobile computer into the cable, ensuring it is correctly seated.

Extreme battery temperature.

Battery does not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Mobile computer was removed from cable or cable was unplugged from AC power too soon.

Ensure cable is receiving power. Ensure mobile computer is seated correctly. If a mobile computer battery is fully depleted, it can take up to four hours to fully recharge the battery.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty battery.

Mobile computer is not fully seated in the cable.

Remove and re-insert the mobile computer into the cable, ensuring it is correctly seated.

Extreme battery temperature.

Battery will not charge if battery temperature is below 32°F (0°C) or above 104°F (40°C).

Cable removed from mobile computer during communication.

Reattach cable to mobile computer and retransmit.

Incorrect cable configuration.

See the system administrator.

Communication software is not installed or configured properly.

Perform setup as described in Chapter 3, ActiveSync.