Page 81

Parameter Menus

UPC Composite Mode UPC symbols can be “linked” with a 2D symbol during transmission as if they were one symbol. Three options are offered for these symbols: !

If UPC Never Linked is selected, UPC bar codes are transmitted regardless of whether a 2D symbol is detected.

!

If UPC Always Linked is selected, UPC bar codes are only transmitted when the 2D portion is detected.

!

If Autodiscriminate UPC Composites is selected, the scanner determines if there is a 2D portion, then transmits the UPC portion only.

UPC Never Linked

UPC Always Linked

Autodiscriminate UPC Composites

3-47

Page 82

CycloneTM M2000 Series Product Reference Guide

Code 128 Enable/Disable Code 128

Enable Code 128

Disable Code 128

Enable/Disable UCC/EAN-128

Enable UCC/EAN-128

Disable UCC/EAN-128

3-48

Page 83

Parameter Menus

Enable/Disable ISBT 128

Enable ISBT 128

Disable ISBT 128

Lengths for Code 128 No length setting is required for Code 128. The default setting is Any Length.

3-49

Page 84

CycloneTM M2000 Series Product Reference Guide

Code 128 Decode Performance This option offers three levels of decode performance or “aggressiveness” for Code 128 symbols. Increasing the performance level reduces the amount of required bar code orientation, which is useful if you are scanning very long and/or truncated bar codes. Increased levels reduce decode security. If you enable this option, you may select a Decode Performance level from the next page to suit your performance needs.

Enable Code 128 Decode Performance

Disable Code 128 Decode Performance

3-50

Page 85

Parameter Menus

Code 128 Decode Performance Level Select a level of decode performance.

Code 128 Decode Performance Level 1

Code 128 Decode Performance Level 2

Code 128 Decode Performance Level 3

3-51

Page 86

CycloneTM M2000 Series Product Reference Guide

Code 39 Enable/Disable Code 39

Enable Code 39

Disable Code 39

Enable/Disable Trioptic Code 39 Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII should not be enabled simultaneously.

Enable Trioptic Code 39

Disable Trioptic Code 39

3-52

Page 87

Parameter Menus

Convert Code 39 to Code 32 Scan a symbol below to select whether or not to convert Code 39 to Code 32. Note: Code 39 must be enabled in order for this parameter to function.

Convert Code 39 To Code 32 (Enable)

Do Not Convert Code 39 To Code 32 (Disable)

3-53

Page 88

CycloneTM M2000 Series Product Reference Guide

Code 32 Prefix Enable this parameter to add the prefix character “A” to all Code 32 bar codes. Convert Code 39 to Code 32 must be enabled for this parameter to function.

Enable Code 32 Prefix

Disable Code 32 Prefix

3-54

Page 89

Parameter Menus

Set Lengths for Code 39 Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. See Table A-3 on page A-6 for ASCII equivalents. !

One Discrete Length - Only codes containing a selected length are decoded. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded.

!

Two Discrete Lengths - Only codes containing two selected lengths are decoded. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded.

!

Length Within Range - A code type within a specified range is decoded. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero).

!

Any Length - Code 39 symbols containing any number of characters can be decoded.

Numeric bar codes begin on page 3-130. If you make an error, or wish to change your selection, scan the Cancel bar code on page 3-132.

3-55

Page 90

CycloneTM M2000 Series Product Reference Guide

Set Lengths for Code 39 (continued)

Code 39 - One Discrete Length

Code 39 - Two Discrete Lengths

Code 39 - Length Within Range

Code 39 - Any Length

3-56