Page 271
Programming Reference
Table A-3. Prefix/Suffix (continued) Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character
Prefix/Suf- Full ASCII Code ASCII fix Value 39 Encode Char. Character
1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094
1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127
%G %H %I %J %V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z %K %L %M %N
< = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^
7013
%O %W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O +P +Q +R +S +T +U +V +W +X +Y +Z %P %Q %R %S
_ ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ Undefined ENTER
A-7
Page 272
CycloneTM M2000 Series Product Reference Guide
A-8
Page 273
Appendix B Specifications M2000 Scanner Specifications Table 2-1 lists the specifications for the M2000 scanner. Table 2-1. Scanner Specifications Item
Description
Power Requirements
5.2 VDC ± 5% @ 300 mA nominal
Laser Diode Power
0.7 mW, max.
Scan Pattern Start Time
0.065 sec. to 75% of steady state horizontal amplitude; 0.50 sec. to 90% of steady state vertical amplitude
Scan Amplitude
Horizontal: 34o ±1.5o Vertical (Omni): 34o ±1.5o Vertical (Raster): 12.5o ±1.5o
Scan Frequency
Horizontal: 320 Hz ±5 Hz Vertical (Omni): 295 Hz ±5 Hz Vertical (Raster): 10 Hz ±1 Hz
Frame Rate
25 frames/sec. 12.5 Hz ±1 Hz (vertical)
Optical Resolution
Can decode a 6.0 mil (minimum X-dimension) symbol (PDF417); Y-dimension must be 2X or greater.
Angular Orientation Tolerances Pitch Tolerance
± 30o (“front to back”)
Skew
± 15o from plane parallel to symbol (“side-to-side”)
B-1
Page 274
CycloneTM M2000 Series Product Reference Guide
Table 2-1. Scanner Specifications (continued) Item
Description
Rotational Tolerance (Raster)
± 4o (for scanning PDF benchmark label, assuming 3:1 codeword aspect ratio). 1D code types depend on height of symbol.
Rotational Tolerance (Omnidirectional)
360o for 1D symbol
Rotational Tolerance (Semi-omni)
± 20o from horizontal
Dead Zone/Optical Throw
± 2o (1-D symbologies) or ± 9o(PDF417) from beam direction
Print Contrast Resolution
35% (1-D symbologies) or 45% (PDF417) absolute dark/light reflectance differential, measured at 650 nm.
Ambient Light Immunity
Up to 8000 ft-candles of sunlight
Humidity
5 - 95% (non-condensing)
Shock
Multiple 4-ft/1.2m drops to concrete
Operating Temperature
0o to 40o C; 32o to 104o F
Storage Temperature
-40o to 60o C; -40o to 140o F
Scanner Connector 10-pin modular connector at base of handle: (see Cable Pinouts on page B-5 for Pin # RS-232/IBM/Synapse USB/Synapse host-end connector of cables) 1 Synapse clock/Flash Synapse clock download RxD (4683) 2 + 5V + 5V 3 Ground Ground 4 Transmit (TxD)/RS-485A VDD 5 Receive (RxD) D+ 6 Ready to Send (RTS)/ RS-485B/ Synapse Data Synapse Data/Flash Download TxD (4683) 7 Clear to Send (CTS) D8 Download Download 9 EAS EAS 10 EAS EAS Coil Cable Length
6 ft.; 183 cm
Weight
12 oz; 340 gm
Height
7.8 in.; 198 mm
Depth
5.4 in.; 137 mm
B-2
Page 275
Specifications
Table 2-1. Scanner Specifications (continued) Item
Description
Width
3.4 in.; 86 mm
Decode Capability
1-D Symbologies: UPC/EAN, Bookland EAN, Code 39, Code 39 Full ASCII, Code 93, Code 128, Codabar, Interleaved 2 of 5, Discrete 2 of 5, MSI Plessey. Cannot autodiscriminate between Code 39 and Code 39 Full ASCII. 2-D Symbology: PDF417, MicroPDF Composite Codes: UCC/EAN, RSS Code
Memory
64K x 16 RAM, 256K x 16 Flash
Decode Zones Following are the decode distances for the M2000 scanner raster and omnidirectional patterns. Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. In. cm Vcc = 5V
2.5 6.35
W i d t h
0 o f
5
Front of Scanner
12.7
0
2.5 6.35 6.6 mil PDF417
0.0
4.0
2.25 2.5
0 0
2 5.1
12.7
6.5
10 mil PDF417, LC 35% 6.75 5.0
In. cm
5
10 mil PDF417
F i e l d
4 10.1
15 mil PDF417
6 15.2
8 20.3
8.5
10 25.4
Depth of Field
Figure B-1. M2000 Raster Pattern Decode Zone
B-3
Page 276
CycloneTM M2000 Series Product Reference Guide
Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. In. cm Vcc = 5V
2.5 6.35
W i d t h
0 o f
5
Front of Scanner
12.7
0
2.5 6.35 6.0 mil Code 39 0.0 2.0
0.0
5
80% UPC
12.7
F i e l d
5.3 100% UPC 11.0
0.3 20 mil Code 39
0.5
In. cm
0 0
2 5.1
4 10.1
6 15.2
8 20.3
12.0
10 25.4
12 30.5
14 35.6
Depth of Field
Figure B-2. M2000 Omnidirectional Pattern Decode Zone
B-4
Page 277
Specifications
Cable Pinouts The following tables describe the pinouts for connector cables.
RS-232 Cable Pinouts Table 2-2. Single-Port RS-232C, 9-Pin Female D-Type Connector P/N 25-32465-01, -02 Pin
Signal
Function
2
RxD
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
5
Ground
Power supply input ground pin and reference for both output signals. Must be capable of sinking all return current.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
RTS
Request-to-send handshaking output line. May be used optionally by the scanner to signal another device that data is available to send. Used only in conjunction with CTS line.
8
CTS
Clear-to-send handshaking input line. Used optionally by another device to signal the scanner that it may commence transmitting data. Used only in conjunction with RTS line.
B-5
Page 278
CycloneTM M2000 Series Product Reference Guide
Table 2-3. Single-Port RS-232C, 8-Pin Female Siemens Nixdorf P/N 25-32469-01, -02 Pin
Signal
Function
SHELL
DRAIN
1
+12V
Converted to +5V.
2
RxD
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
5
Ground
Power supply input ground pin and reference for both output signals. Must be capable of sinking all return current.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
RTS
Request-to-send handshaking output line. Used optionally by the scanner to signal another device that data is available to send. Used only in conjunction with the CTS line.
8
CTS
Clear-to-send handshaking input line. Used optionally by another device to signal the scanner that it may commence transmitting data. Used only in conjunction with RTS line.
B-6
Page 279
Specifications
IBM 46XX Cable Pinouts Table 2-4. IBM 46XX Port 5B 8-Pin SDL Connector P/N 25-32466-01, -02 Pin
Signal
Function
3
GND
Power supply ground pin and reference for both output signals. Must be capable of sinking all return current.
4
Serial I/O A
Differential driver output/receiver input.
5
Serial I/O B
Differential driver output/receiver input.
6
+5V
Power.
Table 2-5. IBM 46XX Port 9B 4-Pin SDL Connector P/N 25-32467-01, -02 Pin
Signal
Function
1
GND
Power supply ground pin and reference for both output signals. Must be capable of sinking all return current.
2
Serial I/O A
Differential driver output/receiver input.
3
Serial I/O B
Differential driver output/receiver input.
4
+12V
Power.
Table 2-6. IBM 46XX Port 17 16-Pin SDL Connector P/N 25-32468-01, -02 Pin
Signal
Function
2
GND
Power supply ground pin and reference for both output signals. Must be capable of sinking all return current.
5
+5V
Power.
7
RS485 A
Differential driver output/receiver input.
8
RS485 B
Differential driver output/receiver input.
SHELL
DRAIN
B-7
Page 280
CycloneTM M2000 Series Product Reference Guide
Table 2-7. IBM Sure One, 8-Pin Connector P/N 25-32470-01, -02 Pin
Signal
Function
2
RxD
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
5, 6, 11
Ground
Power supply input ground pin and reference for both output signals. Must be capable of sinking all return current.
7, 10
+5V / +12V
Power.
12
DTR
Data Terminal Ready. This signal is hardwired active.
13
RTS
Request-to-send handshaking output line. Used optionally by the scanner to signal another device that data is available to send. Used only in conjunction with CTS line.
14
CTS
Clear-to-send handshaking input line. Used optionally by another device to signal the scanner that it may commence transmitting data. Used only in conjunction with RTS line.
FERRULE
DRAIN
Synapse Cable Pinouts Table 2-8. 6-Pin Male Modular Connector for Synapse Cable P/N 25-32463-01, -02 Pin
Signal
Function
1
SYNDATA
Synapse-compatible data line. Bi-directional.
2
SYNCLK
Synapse-compatible clock line. Bi-directional.
3
VCC
Power.
4
GND
Power supply ground pin and reference for both output signals. Must be capable of sinking all return current.
B-8