The text of a manual · part 1 of 2
Cyclone M2000 Series Quick Reference, pages 1 to 8
Pages 1 to 8 of 16
The original document is the PDF (721 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol M2004 and Symbol M2005
Page 1
oOo >o
Oo symbol
Page 2
M
2
C 0 y 0 c 0 l o S n e e r
TM i e s
2000-03 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are a registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894; 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647; 6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213; 6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; 6,380,949; 6,394,355; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187, NI-068564 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713 rev. 06/02
Page 3
Q u i c k
R e f e r e n c e
Introduction The CycloneTM M2000 Series scanner combines the benefits of multiple scan patterns (omni-directional, 2D raster, single scanline and semi-omni directional scan pattern) with a light-weight, hands-free/hand-held design. The scanner’s built-in stand seamlessly accommodates both counter-top and hand-held use. The scanner can be programmed to emit the preferred scan pattern for both counter-top and hand-held use. The following models are available: •
• •
• • •
M2004-I200 (RS-232C) contains on-board discrete RS232C communications for connecting to RS-232C asynchronous terminals and host systems. It also accommodates Synapse™ Smart Cables which allow you to connect to a wide variety of host systems. M2004-I290 (RS-232C with EAS) also supports Checkpoint VII Electronic Article Surveillance (EAS). M2005-I200 (IBM 468X/469X) is fully compatible with the entire line of IBM 468X/469X terminals. It also accommodates Synapse Smart Cables. M2005-I290 (IBM 468X/469X with EAS) provides additional signal lines for EAS deactivation (Checkpoint VII). M2007-I200 (USB) supports USB connectivity. It also accommodates Synapse Smart Cables. M2007-I290 (USB with EAS) provides additional signal lines for EAS deactivation (Checkpoint VII).
1
Page 4
M
2
C 0 y 0 c 0 l o S n e e r
TM i e s
Setting Up your Scanner
3. Connect power supply (if necessary).
1. Listen for click.
Interface Cable
2. Connect to host.
If you are using a Synapse cable, the scanner autodetects your host. If you are using another cable, set the M2000 to communicate with your particular POS host by scanning the appropriate bar code(s) in the CycloneTM M2000 Series Product Reference Guide. Power up the host. The green LEDs on top of the scanner flash 3 times while 3 power-up beeps sound, indicating the scanner is operational.
2
Page 5
Q u i c k
R e f e r e n c e
Removing the Interface Cable Different cables are required for different hosts. To remove the interface cable: 1. Unplug the cable’s modular connector by depressing the connector clip through the access hole on the bottom of the scanner with a screwdriver or paper clip.
Access Hole
2. Carefully slide out the cable.
Wall Mounting the Scanner An optional wall-mount bracket is available for using the M2000 in “scanning from above” applications. To wall-mount the M2000: 1. Place the bracket in its desired location on the wall, and place a pencil mark on the wall through each keyhole in the bracket. 2. Remove the bracket, and insert three #6 screws into the pencil marks on the wall. Do not tighten them all the way; leave enough space for the bracket’s keyholes to slide onto.
3
Page 6
M
2
C 0 y 0 c 0 l o S n e e r
TM i e s
3. Insert the bracket’s keyholes over the screws, and slide the bracket down to secure. If necessary, tighten the screws.
4. Slide the base of the scanner into the bracket with the scan window facing down.
Electronic Article Surveillance (EAS) (Optional) Because there are several Checkpoint EAS systems available, your local Checkpoint representative should install the EAS cable. To contact your local Checkpoint representative inside the U.S. call 800-257-5540, ext. 4300. Outside the U.S., call (609) 8481800, ext. 4300. If you are using an EAS cable, refer to the Universal Cable EAS Installation Sheet (Symbol p/n 70-32824-xx).
Scanning Modes The M2000 may be used on the counter-top or in a hand-held orientation. In hand-held use, the scanner operates in triggered mode where you pull the trigger to activate the scan pattern and decode the bar code. In counter-top use, the scanner operates in continuous (constant-on) mode, where it automatically decodes a bar code presented in its field of view.
4
Page 7
Q u i c k
R e f e r e n c e
Laser Patterns The scanner emits one of four laser patterns: •
•
•
•
Cyclone Omnidirectional Scan Pattern is a highly efficient scan pattern which decodes 1D and EAN/UCC reduced space symbologies in any orientation. Cyclone Semi-omnidirectional Scan Pattern, an alternative to the full omnidirectional pattern, scans highly truncated 1D and RSS bar codes. The bar code must be presented horizontally with no more than 20o tilt. Raster Scan Pattern directly opens the laser to a full sized raster pattern. Decodes 1D, PDF-417, RSS, and Composite Codes. Single Scan Line Pattern (Smart Raster) creates a single scan line which opens vertically for PDF-417 symbols using the Smart Raster feature. This feature autodetects the type of bar code being scanned and adjusts its pattern accordingly. This provides optimal performance on 1D, PDF-417, EAN/ UCC, RSS and Composite Codes.
5
Page 8
M
2
C 0 y 0 c 0 l o S n e e r
TM i e s
One pattern can be selected for counter-top mode and another for hand-held mode via programming bar code in the M2000 Series Product Reference Guide (p/n 72-39696-xx). For hand-held mode, you may alternatively select a pattern by pressing the Scan Pattern Mode Selector button when the scanner is lifted off the counter. Raster Scan Pattern Indicator Omni/Semi-omni Scan Pattern Indicator
Scan Pattern Mode Selector
Single Scan Line (Smart Raster) Pattern Indicator
To scan in hand-held mode, pick up the scanner and hold it within the scanning range for the bar code. A sensor on the bottom of the scanner’s stand detects when the scanner is lifted off the counter, and automatically switches to the programmed hand-held laser pattern.