Page 41
Chapter 5 Programming the LS 6800 Before programming, follow the pertinent setup instructions in Chapter 2, Setup. This chapter provides parameter descriptions and programming bar codes. The General Parameter Table beginning on page 5-3 and Macro PDF Parameter Table on page 5-7 show selectable parameters and standard default values for the LS 6800. If the default values suit your requirements, all you need to do is scan the SET DEFAULT bar code. Parameters other than default values can be set by scanning single bar codes or short bar code sequences. Bar codes are arranged up to four per page in a way that you can present the bar code you want to scan directly to the LS 6800, leading with the appropriate edge of this four-sided, folded-over manual. Note that all parameter settings are stored in non-volatile memory and so are retained after power down.
Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to set the baud rate to 9600, simply scan the 9600 bar code listed under BAUD RATE. The scanner issues a warble tone, signifying a successful parameter entry. If you want to set specific code lengths or specify Serial Response Time-Out, you have to scan several bar codes. This procedure is described in this chapter.
Errors While Scanning Don't worry if you make an error during a scanning sequence. Just reenter the correct parameter. 5-1
Page 42
LS 6800 Product Reference Guide
Set Defaults Scanning the SET DEFAULT bar code returns all parameters to the values listed in Table 5-1 and Table 5-2.
<FN3>91 SET DEFAULTS
5-2
Page 43
Programming the LS 6800
General Parameter Table The following table provides general parameter selections and defaults. Table 5-1. General Parameter Table Parameter
Selection
Default
Set Defaults
None
Set Default Values
Host Selection
RS-232, Null
RS-232
Parameter Program via RS-232 (Simple Scanner Control)
Enabled, Disabled
Enabled
Code Types Enabled
UPC-A, UPC-E, EAN-8, EAN-13, Code 128, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar, Interleaved 2 of 5, Discrete 2 of 5, UCC/EAN 128, Bookland EAN, UPC/EAN Coupon Code, MSI Plessey, PDF417, MicroPDF417
UPC-A/E, EAN-8/ 13, Code 128, Code 39, UCC/EAN 128, PDF417
Code 39 Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 01-55
Code 93 Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 04-55
Codabar Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 05-55
Interleaved 2 of 5 Lengths
Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths
1 Discrete Length 14
Discrete 2 of 5 Lengths
Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths
1 Discrete Length 12
MSI Plessey Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Any Length
5-3
Page 44
LS 6800 Product Reference Guide
Table 5-1. General Parameter Table (Cont’d) Parameter Decode Options: Transmit UPC-A Check Digit Transmit UPC-E Check Digit Convert UPC-E to UPC-A Code 39 Check Digit Verification Transmit Code 39 Check Digit I 2 of 5 Check Digit Verification Transmit I 2 of 5 Check Digit Convert I 2 of 5 to EAN-13 MSI Plessey Check Digits
Selection Enabled, Disabled Enabled, Disabled Enabled, Disabled Enabled, Disabled Enabled, Disabled Enabled, Disabled Enabled, Disabled Enabled, Disabled One, Two
Transmit MSI Plessey Check Digit Enabled, Disabled Mod 10/Mod 10, MSI Plessey Check Digit Mod 10/Mod 11 Algorithm Enabled, Disabled Convert EAN-8 to EAN-13 Decode UPC-EAN Supplemental Enabled, Disabled, Auto Enabled, Disabled CLSI Editing Enabled, Disabled NOTIS Editing None, Symbol Std., AIM Std. Transmit Code ID Character Enabled, Disabled Decode Buffering Transmit “No Decode” Message Enabled, Disabled Enabled, Disabled Transmit LRC Checksum None, System Character, System UPC-A Preamble Character & Country Code None, System Character, System UPC-E Preamble Character & Country Code Enabled, Disabled Code 128 Emulation (MicroPDF417 only) Decode, Ignore, AutoUCC/EAN-128 Emulation discriminate Linked Symbol (MicroPDF417 only) 0.0 to 9.9 seconds Pause Duration 4-Digit ASCII Value Prefix/Suffix Values Scan Data Transmission Format <Data>; <Data><Suffix>; <Prefix><Data><Suffix>; <Prefix><Data>
5-4
Default Enabled Enabled Disabled Disabled Disabled Disabled Disabled Disabled One Disabled Mod 10/Mod 10 Disabled Disabled Disabled Disabled None Disabled Disabled Disabled None None Enabled
Ignore 0.0 seconds Enter <Data>
Page 45
Programming the LS 6800
Table 5-1. General Parameter Table (Cont’d) Parameter Scanning Options: Beep After Good Decode Beeper Tone Decode Attempt Duration Trigger Modes Scanning Modes
Raster Height Raster Expansion Speed Aiming Mode Time Delay to Low Power Mode Timeout Between Decodes: Same Symbol Timeout Between Decodes: Different Symbol FAT Mode Security Options: Decode UPC/EAN Supplemental Redundancy Linear Code Type Security Levels Bi-directional Redundancy UPC/EAN Security Levels Host Port RS-232 Options: Baud Rate Parity Check Parity of Received Data Stop Bit Select Hardware Handshaking Software Handshaking Intercharacter Delay
Selection
Default
Enabled Enabled, Disabled High High, Medium. Low 5 seconds 0.0 to 9.9 seconds; Infinite Level, Pulse, Continuous, Blinking Blinking Smart Raster Smart Raster, Always Raster, Programmable Raster, Slab Raster, Line Pattern 15 1-15 11 1-15 Aiming Dot (Normal or Extended Timeout), Slab Raster Slab Raster 30-second, 1-, 2- , or 3- minutes 30 seconds 0.0 to 9.9 seconds
0.6 seconds
0.0 to 9.9 seconds Enabled, Disabled
0.0 seconds Disabled
2 - 20 1-4 Enabled, Disabled 0-3
7 1 Disabled 1
9600 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4 K Even, Odd, Mark, Space, None None Enabled Enabled, Disabled One One, Two None, RTS/CTS Options 1, 2, 3 None None, ENQ, ACK/NAK, ACK/ NAK with ENQ, XON/XOFF None 0 00 - 99 ms.
5-5
Page 46
LS 6800 Product Reference Guide
Table 5-1. General Parameter Table (Cont’d) Parameter
5-6
Selection
Default
Host Serial RTS Line State
Low RTS, High RTS
Low RTS
Serial Response Time-out
00 - 9.9 seconds
2.0 seconds
Beep on <BEL>
Enabled, Disabled
Disabled
8-Bit ASCII Format
7-Bit ASCII, 8-Bit ASCII
8-Bit ASCII
Page 47
Programming the LS 6800
Macro PDF Parameter Table The following table provides Macro PDF parameter selections and defaults. Table 5-2. Macro PDF Parameter Table Parameter
Selection
Default
Macro PDF Transmit/Decode Mode
Buffer All Symbols / Transmit Buffer All Symbols / Transmit Macro PDF When Complete Macro PDF When Complete Transmit Any Symbol in Set / No Particular Order Scan in Sequence Only / Transmit in Sequence Without Buffering Buffer Scans Out of Order / Transmit Scans in Order
Transmit Each Symbol in Codeword Format
Enabled or Disabled
Disabled
Escape Characters
None, GLI Protocol, ECI Protocol
None
Character Set ECIs
Delete or Transmit
Delete
ECI Decoder
Enabled or Disabled
Enabled
Transmit Unknown Codewords
Enabled or Disabled
Disabled
Enabled or Disabled Enabled or Disabled Enabled or Disabled Enabled or Disabled Enabled or Disabled Enabled or Disabled Enabled or Disabled Enabled or Disabled
Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
Enabled or Disabled
Disabled
Transmit Macro PDF UserSelected Field Transmit File Name Transmit Block Count Transmit Time Stamp Transmit Sender Transmit Addresses Transmit File Size Transmit Checksum Transmit Macro PDF Control Header Last Block Marker
5-7
Page 48
LS 6800 Product Reference Guide
Host Selection This determines whether the LS 6800 interfaces with an RS-232C host, a Synapse host, or no host.
<FN3>2050A37 RS-232 HOST
SYNAPSE HOST
See the Synapse Interface Guide for this bar code.
NULL HOST <FN3>2050AFE
5-8
Page 49
Programming the LS 6800
Parameter Programming via RS-232C (Simple Scanner Control, Enable and Disable) Parameters are stored in non-volatile memory, and they control different options for scanner operation. These are usually programmed by scanning special Code 128 bar codes, which begin with <FN3>, from this manual. However, by enabling parameter programming via RS232, you can program the scanner through host command to the scanner’s RS-232 port, a capability contained in a feature set called Simple Scanner Control. Command Syntax. When using Simple Scanner Control, program a scanner parameter by sending a string to the scanner in this format: 13XXXX<parameter bar code> where <parameter bar code> refers to the string of characters (found under each programming bar code in this manual, minus the <FN3> character) encoded in the bar code for the parameter option you wish to set, and XXXX is a four-digit hexadecimal number representing the number of characters in the command. For example, to enable Pulse Trigger, send: 13000D2050202. To disable Pulse Trigger, send 13000D2050200. Depending on the application environment, it may be possible to enable LRC checksum and ACK/NAK protocols for this communication. See LRC Checksum on page 5-43 and Software Handshaking on page 5-86. Optional T Character. An optional ‘T’ character can be added to the string <parameter bar code> to indicate a temporary change to the value of a parameter which lasts only during one power cycle. After that cycle, the value returns to that saved in the unit’s EEPROM. The ‘T’ character option does not apply for numerical keypad entries, Set Defaults, or for other parameters (e.g., Flush Macro PDF Buffer) which perform a single, isolated action rather than change a parameter setting in EEPROM. The ‘T’ character counts in the total to be entered in the XXXX field. Two parameters which require scanning several bar codes can be changed by sending a single RS-232 command. These parameters are Raster Height and Raster Expansion Rate. Their respective single RS-232 commands are: 13000D20N030X and 13000D20N020X, where X is a hexadecimal value between 1 and F inclusive, representing the parameter value. Sending two consecutive ESC characters (ASCII decimal value 27) resets the command parser. At least 1.25 seconds must elapse after a parameter change in EEPROM before the scanner can accept another parameter change command. With temporary parameter changes, at least 100 ms must elapse between consecutive commands.
5-9
Page 50
LS 6800 Product Reference Guide
Select whether the LS 6800 can be programmed through commands from the host to the scanner’s RS-232 port.
<FN3>1040621 ENABLE SIMPLE SCANNER CONTROL
DISABLE SIMPLE SCANNER CONTROL <FN3>1040620
5-10