The text of a manual · part 4 of 25
LS 6800 Product Reference Guide, pages 31 to 40
Pages 31 to 40 of 249
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Symbol LS-6804
Page 31
Scanning with the LS 6800
LS 6800 Decode Zones 1-D Bar Codes NOTE: Typical performance at 68o F (20o C) on high quality symbols.
.006 In. (.015 cm)
Depth of Field in Inches
.0075 In. (.019 cm)
0
In.
Cm.
.020 In. (.051 cm) Minimum Element Width .040 In. (.102 cm) Minimum Element Width .055 In. (.140 cm) Minimum Element Width 0 1 2 0
4
6 12.7
8
10 12 25.4
14 16 38.1
18
20 22 50.8
25.4 12.7
12.7 25.4
Width of Field in Inches
Nose of the Scanner
10 8 6 5 4 2 0 2 4 5 6 8 10
In. Cm.
24 26 28 30 76.2 63.5
LS 6800 1-D Decode Zone: Depth of field as a function of minimum element width.
PDF417 Bar Codes
Nose of the Scanner
Depth of Field in Inches
5
12.7
2.5
6.4
0
0
2.5
6.4
5
12.7
In.
Cm.
.0066 In. (.017 cm) .010 In. (.025 cm) Minimum Element Width .015 In. (.038 cm) Minimum Element Width 0 0
1 2.5
2 5.1
4 10.1
6 15.2
8 20.3
10 25.4
12 30.5
Width of Field in Inches
NOTE: Typical performance at 68o F (20o C) on high quality symbols. Y-module dimension = 3 X.
In. Cm.
LS 6800 2-D Decode Zone: Depth of field as a function of minimum element width.
Figure 3-11. LS 6800 Decode Zones 3-11
Page 32
LS 6800 Product Reference Guide
3-12
Page 33
Chapter 4 Maintenance and Specifications Maintenance The LS 6800 scanner and power supply are designed to provide reliable service over an extended period of time with virtually no maintenance. For the scanner, the only maintenance required is periodic cleaning of the exit window. t t t t
Do not allow any abrasive material to touch the window. Remove any dirt particles with a damp cloth. Wipe the window using a tissue moistened with ammonia/water. Do not spray water or other cleaning liquids directly into the window.
What If ... Nothing happens when you follow the operating instructions? t t t t t t
Check the system power. Make sure you are using the correct interface cable for the host device. Check for loose cable connections. Make sure the scanner is programmed to decode the symbology you are trying to read. See Chapter 5, Programming the LS 6800 and Chapter 6, Advanced Data Formatting. Check the bar code to make sure it is not severely defaced. Try scanning a test symbol of the symbology you are trying to read.
4-1
Page 34
LS 6800 Product Reference Guide
Your terminal operates but scanned data is not displayed correctly? t t t
Check the system power. Check for loose cable connections. Check that the communication parameters (baud rate, parity, stop bits, etc.) are set properly for the receiving device.
Your terminal is operative but scanned data is not displayed? Or is displayed improperly on the screen? t t
If you’re working with a Synapse cable, refer to your Synapse Interface Guide. If you’re working in RS-232C single-port mode, check that the following parameters have been programmed correctly: > Baud Rate > Stop Bits > Parity > Bits per Character
The laser does not activate, followed by a beep sequence? t
You may be scanning in an inappropriately hot environment. Remove the scanner from the environment, or allow the laser to cool down.
Accessories Required Accessories The following items, required for a complete system, are available through contacting your local Symbol representative or business partner. ITEM
Part Number
Host Interface Cables for RS-232 Operation (Available in 14’ straight lengths) 25-Pin, Male, D Connector (TxD on Pin 3) 25-17228-XX 25-Pin, Male, D Connector (TxD on Pin 2) 25-17229-XX 25-Pin, Female, D Connector (TxD on Pin 3) 25-17230-XX 25-Pin, Female, D Connector (TxD on Pin 2) 25-17231-XX 9-Pin, Female, D Connector (PC AT: TxD on Pin 3) 25-17232-XX Synapse Adapter Cable (10-pin, Male)
25-17233-XX
Power Supply (Select One): 115 VAC Power Supply
50-14000-008
4-2
Page 35
Maintenance and Specifications
220/240 VAC Power Supply (Europe) 100 VAC Power Supply (Japan)
50-14000-009 50-14000-010
User Documentation LS 6800 Product Reference Guide
70-35933-XX
Optional Accessories The following items not included in the standard configuration are available through contacting your local Symbol representative or business partner. ITEM Wall-Mount Bracket Desk Stand
Technical Specifications The following table provides technical specifications for the LS 6800 scanner. Table 4-1. LS 6800 Specifications Item
Description
Power Requirements
+5 V, 400 mA Typical
Laser Diode Power
1.0 mW, max.
Scan Pattern Start Time: Pattern Size: Scan Rate: Frame Rate: Optical Resolution:
0.065 sec. to 75% of steady state horizontal amplitude; 0.50 sec. to 90% of steady state vertical amplitude At 9.5 in. from the nose of the scanner, the pattern is 7.2 in. horizontally and 2.4 in. vertically. 560 scans/sec. 280 Hz ±15 Hz (horizontal) 25 frames/sec. 12.5 Hz ±1 Hz (vertical) Can decode a 6.6 mil (minimum X-dimension) symbol (PDF417); Y-dimension must be 3X for PDF417 and 2X for MicroPDF417. High Density version available (4 mil minimum).
4-3
Page 36
LS 6800 Product Reference Guide
Table 4-1. LS 6800 Specifications (Cont’d) Item Angular Orientation Tolerances Pitch Tolerance: Skew: Rotational Tolerance: Dead Zone/Optical Throw: Print Contrast Resolution
Description ± 30o (“front to back”) ± 15o from plane parallel to symbol (Òside-to-sideÓ) ± 4o (for scanning benchmark label, assuming 3:1 codeword aspect ratio) ± 2o (1-D symbologies) or ± 9o(PDF417) from beam direction 25% (1-D symbologies) or 35% (PDF417) absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity
Up to 8000 ft-candles of sunlight
Humidity
5 - 95% (non-condensing)
Shock
3-ft drop to concrete
Environmental Sealing
NEMA 12 rating; drip-proof, dust-tight
Operating Temperature
-20o to 40o C; -4o to 104o F
Storage Temperature
-40o to 60o C; -40o to 140o F
Scanner Connector
DB-15 modular connector Pins 1, 2: + 5V power supply Pin 3: Transmit (TxD) Pin 4: Receive (RxD) Pin 5: Request to Send (RTS) Pin 6: Clear to Send (CTS) Pin 7: Synapse control data Pin 8: Synapse control clock Pin 9: Data Terminal Ready (DTR) Pin 10: Trigger signal output/input Pin 11: Ground Pin 12: Scan LED (output) Pin 13: Beeper (output) Pin 14: Decode LED (output) Pin 15: Ground
Straight Cable Length
14 ft.
427 cm
Weight
22 oz
624 gm
Height
1.75 in.
4.4 cm
Length
4.5 in.
11.4 cm
4-4
Page 37
Maintenance and Specifications
Table 4-1. LS 6800 Specifications (Cont’d) Item
Description
Width
2.75 in.
7 cm
Agency Approvals
CDRH Class II, IEC 825 Class II, FCC Class A, UL, CSA, VDE, CE
Decode Capability
1-D Symbologies: UPC-A, UPC-E, EAN-8, EAN-13, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Code 128, Interleaved 2 of 5, Discrete 2 of 5, Codabar, UCC/EAN 128, Bookland EAN, UPC/EAN Coupon Code, MSI Plessey. Cannot autodiscriminate between Code 39 and Code 39 Full ASCII. 2-D Symbologies: PDF417 (up to 928 codewords at security level 0 - 8), MicroPDF417.
Memory
Two models: 64K RAM, 256K Flash; 256K RAM, 256K Flash
Cable Pinouts The following tables provide cable pinout information. Table 4-2. Single Port RS-232C, 25-Pin Male, D-Type Connector - p/n 25-17228-01 Pin
Signal
Function
2
RxD
Serial data receive input, driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. This drives the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line, used optionally by another device to signal the scanner to begin transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line, used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
4-5
Page 38
LS 6800 Product Reference Guide
Table 4-3. Single-Port RS-232C, 25-Pin Male, D-Type Connector, p/n 25-17229-01 Pin
Signal
Function
2
TxD
Serial data transmit output. This drives the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input, driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line, used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
5
CTS
Clear-to-send handshaking input line, used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
Table 4-4. Single-Port RS-232C, 25-Pin Female, D-Type Connector, p/n 25-17230-01
4-6
Pin
Signal
Function
2
RxD
Serial data receive input, driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. This drives the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line, used optionally by another device to signal the scanner to begin transmitting data. It can be used only in conjunction with the RTS line.
Page 39
Maintenance and Specifications
Table 4-4. Single-Port RS-232C, 25-Pin Female, D-Type Connector, p/n 25-17230-01 (Cont’d) Pin
Signal
Function
5
RTS
Request-to-send handshaking output line, used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
Table 4-5. Single-Port RS-232C, 25-Pin Female, D-Type Connector, p/n 25-17231-01 Pin
Signal
Function
2
TxD
Serial data transmit output. This drives the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input, driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line, used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line
5
CTS
Clear-to-send handshaking input line, used optionally by another device to signal the scanner to begin transmitting data. It can be used only in conjunction with the RTS line.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
4-7
Page 40
Maintenance and Specifications
Table 4-6. Single-Port RS-232C, 9-Pin Female, D-Type Connector (PC/AT), p/n 25-17232-01 Pin
Signal
Function
2
RxD
Serial data receive input, driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. This drives the serial data receive input on the device communicating with the scanner.
5
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
6
DTR
Data terminal ready. Hardwired active.
7
CTS
Clear-to-send handshaking input line, used optionally by another device to signal the scanner to begin transmitting data. It can be used only in conjunction with the RTS line.
8
RTS
Request-to-send handshaking output line, used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line
Table 4-7. 10-Pin Male Modular Connector for Synapse Cable, p/n 25-17233-01 Pin
Signal
Function
1
SYNDATA
Synapse-compatible data line. Bi-directional line.
2
SYNCLK
Synapse-compatible clock line. Bi-directional line.
3
VCC
Power.
4
GND
Power supply ground pin and reference for both output signals. It must be capable of sinking all return current.
4-8