Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 3

LS 6000 Series Quick Reference, pages 1 to 10

Pages 1 to 10 of 28

The original document is the PDF (198 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-6005 and Symbol LS-6004

Page 1 read from a scan by OCR; it may hold reading errors

L ss)

6 000 #§ au suee i. wy anne suzbol

Page 2

L S

6 0 0 0

S e r i e s

© 2000 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172, D418,500; D419,548; D423,468; D424,035 D431,158; D430,159; D431,562. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 09/00

Page 3

Q u i c k

R e f e r e n c e

Purpose This Quick Reference Guide is designed to assist you during routine LS 6000 operation. Detailed information about setting up and programming your scanner can be found in the LS 6000 Series Product Reference Guide (Symbol p/n 70-33186-XX).

Product Description The LS 6000 Series scanner combines the benefits of omnidirectional scanning with a light-weight, hand-held design. The scanner converts easily to hands-free use with an optional presentation stand. The following models are available: •

• •

• • •

LS6004i-I000 (RS-232C) contains on-board discrete RS232C communications for connecting to RS-232C asynchronous terminals and host systems. It also accommodates Synapse™ Smart Cables which allow you to connect to a wide variety of host systems. LS6004i-I090 (RS-232C with EAS) also supports Checkpoint VII Electronic Article Surveillance (EAS). LS6005i-I000 (IBM 468X/469X) is fully compatible with the entire line of IBM 468X/469X terminals. It also accommodates Synapse Smart Cables. LS6005i-I090 (IBM 468X/469X with EAS) provides additional signal lines for EAS deactivation (Checkpoint VII). LS6007i-I000 (USB) supports USB connectivity. It also accommodates Synapse Smart Cables. LS6007i-I090 (USB with EAS) provides additional signal lines for EAS deactivation (Checkpoint VII).

Using Your Scanner If the scanner is powered by the host, ensure the host is connected to a power outlet. When power is applied to the host, the scanner powers up. 1

Page 4

L S

6 0 0 0

S e r i e s

If the scanner is powered by an external power supply, ensure the power supply is connected to a power outlet. When the power supply is connected to the scanner, the scanner powers up. The green LED on top of the scanner illuminates and 3 power-up beeps sound, indicating the scanner is operational. The LS 6000’s LED and beeper indicate scanning activity. These indications are described later in this guide. If the scanner is inactive for more than a pre-programmed length of time, it enters a rest mode to conserve energy. When you need to scan again, just bring a bar code to the scanner window to “wake up” the scanner. If you have any problems using the scanner, contact your technical support person for assistance.

Installing the Scanner Cable To connect the cable to the LS 6000 scanner: 1. Switch off all devices connected to the LS 6000 cable. 2. Plug the modular connector on the cable into the receptacle in the bottom of the LS 6000 handle. Listen for a click.

3. Gently tug the cable to ensure the connector is properly secured. 2

Page 5

Q u i c k

R e f e r e n c e

Switching Cables Different cables are required for different hosts. To change the scanner cable: 1. Unplug the installed cable’s modular connector by depressing the connector clip with a screwdriver or paper clip (through the access hole). 2. Carefully slide out the cable. 3. Follow the steps for Installing the Scanner Cable to connect a new cable.

Electronic Article Surveillance (EAS) (Optional) Because there are several Checkpoint EAS systems available, your local Checkpoint representative must install the EAS cable. To contact your local Checkpoint representative inside the U.S. call 800-257-5540, ext. 4300. Outside the U.S., call (609) 8481800, ext. 4300. If you are using an EAS cable, refer to the Universal Cable EAS Installation Sheet (Symbol p/n 70-32824-XX).

3

Page 6

L S

6 0 0 0

S e r i e s

Scanning In Hand-Held Mode The LS 6000 may be placed on the counter-top or in the Desk Mount Stand (optional). The scanner operates in one of the following three scanning modes, programmable by the bar codes that begin on page 12: •

• •

Combination Mode The omnidirectional scan pattern is always on and ready to decode. When the trigger is pulled, the scanner emits a single scan line to decode, then reverts back to omnidirectional constant-on. This mode is only for hand-held use. Triggered Omnidirectional Mode (Default) An omnidirectional scan pattern activates upon trigger pull. Triggered Single Scan Line Mode A single scan line appears upon trigger pull.

To scan in hand-held mode, pick up the scanner and hold it within the scanning range for the bar code. If the scanner is in the constant-on mode, it decodes the bar code automatically. If the scanner is in trigger mode, pull the trigger to activate the scan pattern and decode the bar code.

4

Page 7

Q u i c k

R e f e r e n c e

Scanning in Hands-Free (Presentation) Mode To place the LS 6000 scanner in the optional hands-free Presentation Stand, slide the rubber “chin” support on the scanner into the notch in the stand until the scanner is firmly seated. The scanner emits a constant-on omnidirectional pattern. To scan a bar code, bring the bar code anywhere within 10 in. (25.4 cm) of the scanner window for a successful decode. Bar codes can either be directed in toward the nose of the scanner (“presentation” scanning) or from side to side in a sweeping motion (“swipe” scanning).

Scanning in the Stand

Inserting LS 6000 into Stand

When the LS 6000 is removed from the Presentation Stand, the scanner operates in the programmed trigger mode (see page 4 for trigger mode descriptions).

Selecting Beeper Volume The LS 6000 emits a short beep when it successfully reads a bar code. There are three volume settings for this decode beep. To change the setting, hold down the trigger for five seconds. The scanner cycles through three settings, emitting a 2-beep tone at each setting. To select a particular setting, release the trigger after the desired 2-beep tone. To adjust the frequency (tone) of the scanner’s beeper, see Beeper Frequency on page 13. 5

Page 8

L S

6 0 0 0

S e r i e s

LED Indications The green LED located on top of the scanner indicates the operational status of the scanner. These LED indications are defined below: LED

Indication

Off

No power is applied to the scanner.

On steady

The scanner is on and “ready to scan,” or a flash download cable is attached.

Momentary flash off

A bar code has been successfully decoded.

Fast double-blinking

The scanner is in a programming sequence.

Fast sequential flashing

A scanner malfunction has occurred.

Slow steady blinking

The scanner is in flash program mode.

Beeper Indications The beeper indicates the scanner’s status as follows: Beeper

Indication

3 Beeps

Power up (or reset) has occurred.

1 Beep

A bar code has been successfully decoded.

4 Beeps

A transmission error has occurred. Bar code data was not received by the host.

Fast warble

A programming parameter was entered successfully.

6

Page 9

Q u i c k

R e f e r e n c e

Programming Bar Codes Following are some frequently used programming bar codes.

Set Defaults Scanning this bar code sets all parameters to their default values.

SET DEFAULTS

Host Type If you’re using a Synapse cable, Synapse autodetects the type of host you’re using, so no bar codes need to be scanned. If not, select an IBM 46XX, RS-232 or USB host from the following bar code menus.

7

Page 10

L S

6 0 0 0

S e r i e s

IBM 46XX Host Types (LS 6005) To select one of the following as a POS interface, scan the appropriate bar code below. Note:

To properly communicate with 468X/9X terminals, the driver corresponding to the port being used must be loaded and enabled when you are configuring your terminal system. See your terminal’s operating manual for details.

PORT 5B

PORT 9B

PORT 17, 9E

8