Page 8

S y m b o l

S c a n n e r

Flash Operation Examples Following are examples of launch scripts for various configurations and operations. The LS 6004 is used for these examples. Note: Examples assume the .FLD files are stored in the local directory c:\symbol\ls6004.

Download Launch Script Examples 1. To program (or download) a scanner with operational software, use the following launch script: Flash

DL-CODE

NULL c:\symbol\ls6004\nbrwnaca.fdl

2. To eliminate the path, use the launch script below to perform the same operation as example #1. This script uses the optional path identifier, which is used for the remaining examples. Flash

DL-CODE

-Pc:\symbol\ls6004\ NULL nbrwnaca.fdl

3. To program a scanner with operational software and load the EEParameters, use the following launch script: Flash

DL

-Pc:\symbol\ls6004\ NULL nbrwnaca.fdl nbrwnpaa.fdl

4. To program several scanners with operational software and load the EEParameters at the “max-baud-rate” in continuous mode (-X), use the launch script below. Flash

DL

-Pc:\symbol\ls6004\

-X

NULL nbrwnaca.fdl nbrwnpaa.fdl

5. To program a scanner with operational software for a PC which only supports baud rates up to 9600, use the “baudrate” option to specify 9600 (-B0) as shown below. (The Flash-Utility program expects the PC to support higher baudrates; running the Flash-Utility program will fail without the baud command below). Flash

DL-CODE

-B0

-Pc:\symbol\ls6004\ NULL nbrwnaca.fdl

Upload Launch Script Examples 1. To read (or Upload) and store a scanner’s operational software into the file code.dat, use the launch script: Flash

UL-CODE

-Pc:\symbol\ls6004\ NULL code.dat

6

Page 9

F l a s h

P r o g r a m m i n g

2. To read and store a scanner’s entire Flash memory into the file entire.dat, use the launch script: Flash

UL

-Pc:\symbol\ls6004\ NULL entire.dat

3. To read and store a portion of the scanner’s Flash memory into the file partial.dat, use the launch script below. The optional parameter -A8000,10000 specifies the start address and length for the partial data. Flash

UL

-A8000,10000

-Pc:\symbol\ls6004\ NULL partial.dat

4. To read and store a scanner’s EEParameters into the file eeps.dat use the launch script: Flash

UL-EEPARAMS

-Pc:\symbol\ls6004\ NULL

7 eeps.dat

Page 10

S y m b o l

S c a n n e r

Flash-Operation Errors Using this Flash utility program can produce two types of errors: Script-Syntax errors, and Flash Programming errors. When a Flash operation is completed, an error code is produced. This error code is a hex number; the tables that follow translate this error code. An error code of zero indicates the operation was successful.

Error Log The launch script and results (error code) of each Flash operation are logged to the file log.dat in your local directory. This file provides a history of the Flash operation. To enable the error logging, include a -L in the launch script.

Launch Script Syntax Errors Most of these are displayed on the output screen as they are encountered. These are typically syntax errors in the launch script (invalid operations, options, etc.) or incorrect or missing file names. Most of these errors can be corrected by fixing the launch script or ensuring the specified files exist. Error

Cause of Error

0x21

Error opening file

0x22

Error reading file

0x23

Error writing file

0x31

Error opening comm port

0x32

Error configuring comm port (may be invalid baud)

0x41

Command specified in launch script is invalid

0x42

Option specified in launch script is invalid

0x43

Launch script syntax is invalid

0x44

The Flash command is not supported

0x50-0x5F

Internal error (defect if this error occurs)

8

Page 11

F l a s h

P r o g r a m m i n g

Flash Programming Errors These are errors in the actual Flash-Utility operation, and are only displayed as an error code at completion of the Flash operation. The scanner’s LED continually blinks the error code that is displayed. Error

Cause of Error

0x01

Receive time-out error

0x02

STX not found

0x03

Packet “len” too long

0x04

Packet chksum failed

0x05

Code chksum failed

0x06

Received block > Block-Size

0x07

General command error

0x08

Illegal command ID

0x09

Unsupported command ID

0x0A

Out-Of-Range Addr

0x0B

Blk# received out-of-sequence

0x0C

Command received out-of-sequence

0x0D

Final download check

0x0E

Specified baud not supported

9

Page 12

70-19963-02 Revision B, March 2001 Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300