Page 5
F l a s h
P r o g r a m m i n g
Flash Utility Operation To run the Flash utility program, launch a Windows application with a “launch script” (Windows File Manager may be used for this). The launch script defines the mode of operation, options and scanner component file names as described in the following sections.
Launch Script Syntax The launch script syntax for all Flash operations is: flash <operation> [P1 P2...] NULL [f1 f2]
Where: flash is the Flash utility applications name (a path may be specified).
<operation> is the type of Flash operation to perform (see Operations on page 4).
[-P1 -P2...] is 1 or more options providing additional program control (see Options on page 4).
NULL is a scanner-specific Flash-Loader file required only for older versions of the Flash utility. For the program on the associated diskette, this is NULL. Note: This must be uppercase.
[f1 f2...] is 1 or 2 files required to perform the Flash operation (see Files on page 5).
3
Page 6
S y m b o l
S c a n n e r
Operations Permissible Flash operations are listed below. Replace the launch script parameter <operation> with one from the first column of the list. Note: These must be uppercase. Depending on the intended Flash operation, specific files must be included in the launch script (see Flash Operation Examples on page 6). DL
Download product code & EEParams
DL-CODE
Download product code only
DL-EEPARAMS
Download EEParameters only
UL
Upload (entire/partial Flash)
UL-CODE
Upload product code only
UL-EEPARAMS
Upload EEParameters
Options Following are the options [-P1 -P2...] supported (* indicates defaults, ** are not supported by Symbol scanners: -Cd
Specifies the PC comport to use (i.e., -C1=com1, *-C2=com2, etc.)
-Bd
Specifies the max baud rate (-B0=9600, -B1=19200, -B2=38400, **-B3=57600, -B4=76800, **-B5=115200, *-B6=153600)
-Ps
Specifies a path for all files (all files following in script)
-Axxxx,xxxx
Start address and length (used for UL command only)
-Wd
Add wait time between packets (use if communication errors occur)
-X
Enable continuous mode (queries user to perform the operation again)
-L
Log results to file log.dat in local directory 4
Page 7
F l a s h
P r o g r a m m i n g
Files The following are allowable launch script files ([f1 f2...]): <prod.fdl>
The scanner’s operational software (i.e., nbrwnaca.fdl)
<eeps.fdl>
The scanner’s power-up operating parameters (i.e., nbrwnpaa.fdl)
<loader.fdl>
The scanner’s specific Flash-Loader software (should be NULL)
<anyfile>
Any file name, this file captures UpLoaded code (i.e., capture.dat)
5