Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

Symbol Scanners Flash Programming: Flash Utility Operation

Pages 5 to 7 of 12, from Symbol Scanners Flash Programming

The original document is the PDF (112 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-6004

Page 5

F l a s h

P r o g r a m m i n g

Flash Utility Operation To run the Flash utility program, launch a Windows application with a “launch script” (Windows File Manager may be used for this). The launch script defines the mode of operation, options and scanner component file names as described in the following sections.

Launch Script Syntax The launch script syntax for all Flash operations is: flash <operation> [P1 P2...] NULL [f1 f2]

Where: flash is the Flash utility applications name (a path may be specified).

<operation> is the type of Flash operation to perform (see Operations on page 4).

[-P1 -P2...] is 1 or more options providing additional program control (see Options on page 4).

NULL is a scanner-specific Flash-Loader file required only for older versions of the Flash utility. For the program on the associated diskette, this is NULL. Note: This must be uppercase.

[f1 f2...] is 1 or 2 files required to perform the Flash operation (see Files on page 5).

3

Page 6

S y m b o l

S c a n n e r

Operations Permissible Flash operations are listed below. Replace the launch script parameter <operation> with one from the first column of the list. Note: These must be uppercase. Depending on the intended Flash operation, specific files must be included in the launch script (see Flash Operation Examples on page 6). DL

Download product code & EEParams

DL-CODE

Download product code only

DL-EEPARAMS

Download EEParameters only

UL

Upload (entire/partial Flash)

UL-CODE

Upload product code only

UL-EEPARAMS

Upload EEParameters

Options Following are the options [-P1 -P2...] supported (* indicates defaults, ** are not supported by Symbol scanners: -Cd

Specifies the PC comport to use (i.e., -C1=com1, *-C2=com2, etc.)

-Bd

Specifies the max baud rate (-B0=9600, -B1=19200, -B2=38400, **-B3=57600, -B4=76800, **-B5=115200, *-B6=153600)

-Ps

Specifies a path for all files (all files following in script)

-Axxxx,xxxx

Start address and length (used for UL command only)

-Wd

Add wait time between packets (use if communication errors occur)

-X

Enable continuous mode (queries user to perform the operation again)

-L

Log results to file log.dat in local directory 4

Page 7

F l a s h

P r o g r a m m i n g

Files The following are allowable launch script files ([f1 f2...]): <prod.fdl>

The scanner’s operational software (i.e., nbrwnaca.fdl)

<eeps.fdl>

The scanner’s power-up operating parameters (i.e., nbrwnpaa.fdl)

<loader.fdl>

The scanner’s specific Flash-Loader software (should be NULL)

<anyfile>

Any file name, this file captures UpLoaded code (i.e., capture.dat)

5