Page 81
LS 6000 Series Product Reference Guide
EAN Zero Extend If this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format.
ENABLE EAN ZERO EXTEND
DISABLE EAN ZERO EXTEND
5-48
Page 82
Programming the LS 6000
UPC/EAN Predecode Block UPC/EAN bar codes are made up of two blocks representing “left” and “right” halves. For example, bar code 1234567890 is divided into left block “12345”, and right block “67890”. To maximize its aggressiveness, the LS 6000 can decode a UPC/ EAN symbol by “splicing” together a left block read by one scan line, and a right block read by another.
Reject Predecode Block This option provides additional protection (beyond the embedded check digit) against mis-splicing a UPC/EAN block from a symbol that has just been decoded (but has not completely exited the scanner’s field of view), with a block from a new symbol that has just been presented to the scanner. This option requires the scanner to compare the new symbol against the symbol just decoded to see if there are common blocks. If either the left or right blocks match between symbols, the scanner rejects the common block for the programmed Decode Time-Off interval.
REJECT PREDECODE BLOCK
5-49
Page 83
LS 6000 Series Product Reference Guide
Accept Predecode Block This option allows immediate decode of a new UPC/EAN bar code regardless of the previously decoded UPC/EAN bar code’s block content.
ACCEPT PREDECODE BLOCK
5-50
Page 84
Programming the LS 6000
UPC/EAN Security Level The LS 6000 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
UPC/EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
UPC/EAN SECURITY LEVEL 0
5-51
Page 85
LS 6000 Series Product Reference Guide
UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to misdecodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.
UPC/EAN SECURITY LEVEL 1
UPC/EAN Security Level 2 If you are experiencing misdecodes of poorly printed bar codes, and the misdecodes are not limited to characters 1, 2, 7, and 8, select this security level.
UPC/EAN SECURITY LEVEL 2
5-52
Page 86
Programming the LS 6000
UPC/EAN Security Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised, selecting this option is an extreme measure against misdecoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.
UPC/EAN SECURITY LEVEL 3
5-53
Page 87
LS 6000 Series Product Reference Guide
Linear UPC/EAN Decode This option applies to code types containing two adjacent blocks (e.g., UPC-A, EAN-8, EAN-13). When enabled, a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other.
ENABLE LINEAR UPC/EAN DECODE
DISABLE LINEAR UPC/EAN DECODE
5-54
Page 88
Programming the LS 6000
Linear Supplemental Decode This option applies to code types containing two or five character supplementals. When enabled, a bar code is transmitted only when both the supplemental block and its adjacent block are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other.
ENABLE LINEAR SUPPLEMENTAL DECODE
DISABLE LINEAR SUPPLEMENTAL DECODE
5-55
Page 89
LS 6000 Series Product Reference Guide
UPC/EAN Decode Performance This option offers three levels of decode performance (aggressiveness) for UPC/EAN symbols without supplementals. Increasing the performance level reduces the amount of required bar code orientation, which is useful if you are scanning very long and/or truncated bar codes. Increased levels reduce decode security. If you enable this option, select a performance level from the next page.
ENABLE UPC/EAN DECODE PERFORMANCE
DISABLE UPC/EAN DECODE PERFORMANCE
5-56
Page 90
Programming the LS 6000
UPC/EAN Decode Performance (Cont’d) If Decode Performance is enabled, select a level below.
UPC/EAN DECODE PERFORMANCE LEVEL 1
UPC/EAN DECODE PERFORMANCE LEVEL 2
UPC/EAN DECODE PERFORMANCE LEVEL 3
5-57