For the Symbol LS-6005 and Symbol LS-6004
Page 51
LS 6000 Series Product Reference Guide
Time to Return to Continuous Omnidirectional This parameter sets the time the scanner issues a single scan line on trigger pull before returning to the constant-on omnidirectional pattern. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. If this value is set to 0, the trigger mode will not return to constant-on omnidirectional automatically. In this case, pull the trigger twice quickly to return to the constant-on omnidirectional pattern. To set this time, scan the bar code. Next scan two numeric bar codes beginning on page 5-117, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-122.
TIME TO RETURN TO CONTINUOUS OMNI
5-18
Page 52
Programming the LS 6000
Beeper Volume To select a decode beep volume, scan the LOW VOLUME, MEDIUM VOLUME, or HIGH VOLUME bar code. Note: Beeper volume can also be set manually using the instructions for Selecting Beeper Volume on page 3-4.
LOW VOLUME
5-19
Page 53
ee |_! LS 6000 Series Product Reference Guide
Beeper Volume (Cont’d)
MEDIUM VOLUME
HIGH VOLUME
5-20
Page 54
Programming the LS 6000
Beeper Frequency To select a decode beep frequency (tone), scan the LOW FREQUENCY, MEDIUM FREQUENCY, or HIGH FREQUENCY bar code.
LOW FREQUENCY
5-21
Page 55
ee |_! LS 6000 Series Product Reference Guide
Beeper Frequency (Cont’d)
MEDIUM FREQUENCY
HIGH FREQUENCY
5-22
Page 56
Programming the LS 6000
Time-out Between Decodes, Same Symbol This parameter sets the minimum time between decodes of the same symbol. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. (Setting this above 0.4 seconds is recommended.) Scan the bar code below to select a new time-out. Next scan two numeric bar codes beginning on page 5-117, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-122.
TIME-OUT BETWEEN SAME SYMBOL
5-23
Page 57
LS 6000 Series Product Reference Guide
Time-out Between Decodes, Different Symbols This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. Scan the bar code below, then scan two numeric bar codes beginning on page 5-117, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-122.
TIME-OUT BETWEEN DIFFERENT SYMBOLS
5-24
Page 58
Programming the LS 6000
Laser On Time This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 5-117 that correspond to the desired time on. Single digit numbers must have a leading zero. For example, to set a Time On of .5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If you make an error, or wish to change your selection, scan CANCEL on page 5-122.
LASER ON TIME
5-25
Page 59
LS 6000 Series Product Reference Guide
Rest Mode Time-out This parameter sets the time the scanner remains active after any scanning activity. Scan one of the four options. Depending on the selection, the scanner enters a low power “rest” mode 15, 30, 60, or 90 minutes after the last attempted decode. The laser blinks during this rest mode to conserve power. To awaken the scanner, present the bar code you wish to scan to the scan window.
15 MINUTES
30 MINUTES
5-26
Page 60
Programming the LS 6000
Rest Mode Timeout (Cont’d)
60 MINUTES
90 MINUTES
5-27