Page 31
LS 6000 Series Product Reference Guide
Table 4-1. Technical Specifications (cont’d) ITEM
DESCRIPTION
Height
7.64 in. (194 mm)
Width
2.72 in. (69 mm)
Depth
3.19 in. (81 mm)
4-4
Page 32
Maintenance and Specifications
What If... Table 4-2. Troubleshooting What if...
Then...
The scanner is not decoding and the green LED is not lit?
Refer to Chapter 2, Setup to verify that your scanner is properly connected.
The scanner is not decoding and the green LED is lit?
Check the bar code to make sure it is not defaced. Verify that the code type you are scanning is enabled. Verify that the symbol length for that code type is correct. Try scanning similar bar codes of the same code type. Make sure the Beep After Good Decode parameter is enabled. Make sure a flash download cable is not being used.
The scanner is not transmitting to the host terminal?
Make sure the scanner is connected to the terminal. Make sure the host terminal is properly configured. Be sure that you've scanned the proper host type. If you’re using RS-232, be sure all RS-232 parameters (e.g., baud rate, data bits, handshaking) are set properly to communicate with the host.
4-5
Page 33
ee |_! LS 6000 Series Product Reference Guide
4-6
Page 34
Chapter 5 Programming the LS 6000 Operational Parameters The LS 6000 is shipped with the settings shown in the Table 51 beginning on page 5-2. These default values are stored in nonvolatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the SET ALL DEFAULTS bar code on page 5-7. If you are using a Synapse cable, your host is autodetected, so no host bar codes need to be scanned. If not, you must select a terminal type even if the default parameters suit your needs. The scanner automatically identifies the host type on power-up. It makes this determination provided the host is powered-up before the scanner is attached to it. You must then select the appropriate terminal type for that host. For example, if the scanner is connected to an IBM 4683, after you hear the powerup beeps, select the proper port from the choices in IBM 46XX Host Types on page 5-8.
5-1
Page 35
LS 6000 Series Product Reference Guide
Defaults The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Table 5-1. Default Table Parameter
Default
Page Number
Set Default Parameter
All Defaults
5-7
Host Type
See page 5-8
5-8
Triggered Omnidirectional
5-16
0.5 seconds
5-18
Beeper Volume
High
5-19
Beeper Frequency
High Frequency
5-21
Time-out Between Decodes, Same Symbol
Triggered: 200 msec; ConstantOn: 2 sec
5-23
Time-out Between Decodes, Different Symbols
600 msec
5-24
Laser On Time
2.0 seconds
5-25
Rest Mode Timeout
30 minutes
5-26
Enable
5-28
2
5-29
Trigger Mode
Time to Return to Continuous Omnidirectional
Beep After Good Decode Linear Code Type Security Levels
5-2
Page 36
Programming the LS 6000
Table 5-1. Default Table (cont’d) Parameter
Default
Page Number
UPC-A
Enable
5-32
UPC-E
Enable
5-32
EAN-8
Enable
5-34
EAN-13
Enable
5-34
Bookland EAN
Disable
5-36
Decode UPC/EAN Supplementals
Ignore
5-37
Decode UPC/EAN Supplemental Redundancy
20
5-39
Transmit UPC-A Check Digit
Enable
5-40
Transmit UPC-E Check Digit
Enable
5-41
Random Weight Check Digit
Disable
5-42
UPC-A Preamble
System Character
5-43
UPC-E Preamble
System Character
5-45
Convert UPC-E to A
Disable
5-47
EAN-8 Zero Extend
Disable
5-48
UPC/EAN Predecode Block
Reject
5-49
UPC/EAN
5-3
Page 37
LS 6000 Series Product Reference Guide
Table 5-1. Default Table (cont’d) Parameter
Default
Page Number
UPC/EAN Security Levels
0
5-51
Linear UPC/EAN Decode
Disable
5-54
Linear Supplemental Decode
Disable
5-55
UPC/EAN Decode Performance
Enable, Level 3
5-56
Disable
5-58
Enable
5-59
Enable, Level 3
5-60
Enable
5-62
Code 39
Enable
5-63
Set Length(s) for Code 39
1 to 55
5-64
Code 39 Check Digit Verification
Disable
5-67
Transmit Code 39 Check Digit
Disable
5-68
Code 39 Decode Performance
Enable, Level 3
5-69
Code 39 Full ASCII Conversion
Disable
5-71
UPC/EAN Coupon Code Code 128 Code 128 Code 128 Decode Performance UCC/EAN-128 Code 39
5-4
Page 38
Programming the LS 6000
Table 5-1. Default Table (cont’d) Parameter
Default
Page Number
Disable
5-73
14
5-74
I 2 of 5 Check Digit Verification
Disable
5-77
Transmit I 2 of 5 Check Digit
Disable
5-79
Convert I 2 of 5 to EAN 13
Disable
5-80
Codabar
Disable
5-81
Set Lengths for Codabar
5-55
5-82
CLSI Editing
Disable
5-85
NOTIS Editing
Disable
5-86
None
5-87
0
5-89
7013 (<CR/LF> for serial)
5-90
Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5
Codabar
Data Options Transmit Code ID Character Pause Duration Prefix/Suffix Values
5-5
Page 39
LS 6000 Series Product Reference Guide
Table 5-1. Default Table (cont’d) Parameter
Default
Page Number
Scan Data Transmission Format
Data as is
5-91
Standard
5-10
Baud Rate
9600
5-95
Parity
Even
5-99
Check Receive Errors
Check
5-102
Hardware Handshaking
None
5-103
Software Handshaking
None
5-107
Host Serial Response Time-out
2 Sec.
5-111
RTS Line State
Low
5-112
Stop Bit Select
1
5-113
ASCII Format
8-Bit
5-114
Beep on <BEL>
Disable
5-115
0
5-116
RS-232C RS-232 Host Type
Intercharacter Delay Numeric Bar Codes
5-6
5-117
Page 40
Programming the LS 6000
Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 5-1 beginning on page 5-2.
SET ALL DEFAULTS
5-7