Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 18

LS 6000 Series Product Reference Guide, pages 31 to 40

Pages 31 to 40 of 175

The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-6005 and Symbol LS-6004

Page 31

LS 6000 Series Product Reference Guide

Table 4-1. Technical Specifications (cont’d) ITEM

DESCRIPTION

Height

7.64 in. (194 mm)

Width

2.72 in. (69 mm)

Depth

3.19 in. (81 mm)

4-4

Page 32

Maintenance and Specifications

What If... Table 4-2. Troubleshooting What if...

Then...

The scanner is not decoding and the green LED is not lit?

Refer to Chapter 2, Setup to verify that your scanner is properly connected.

The scanner is not decoding and the green LED is lit?

Check the bar code to make sure it is not defaced. Verify that the code type you are scanning is enabled. Verify that the symbol length for that code type is correct. Try scanning similar bar codes of the same code type. Make sure the Beep After Good Decode parameter is enabled. Make sure a flash download cable is not being used.

The scanner is not transmitting to the host terminal?

Make sure the scanner is connected to the terminal. Make sure the host terminal is properly configured. Be sure that you've scanned the proper host type. If you’re using RS-232, be sure all RS-232 parameters (e.g., baud rate, data bits, handshaking) are set properly to communicate with the host.

4-5

Page 33 read from a scan by OCR; it may hold reading errors

ee |_! LS 6000 Series Product Reference Guide

4-6

Page 34

Chapter 5 Programming the LS 6000 Operational Parameters The LS 6000 is shipped with the settings shown in the Table 51 beginning on page 5-2. These default values are stored in nonvolatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the SET ALL DEFAULTS bar code on page 5-7. If you are using a Synapse cable, your host is autodetected, so no host bar codes need to be scanned. If not, you must select a terminal type even if the default parameters suit your needs. The scanner automatically identifies the host type on power-up. It makes this determination provided the host is powered-up before the scanner is attached to it. You must then select the appropriate terminal type for that host. For example, if the scanner is connected to an IBM 4683, after you hear the powerup beeps, select the proper port from the choices in IBM 46XX Host Types on page 5-8.

5-1

Page 35

LS 6000 Series Product Reference Guide

Defaults The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Table 5-1. Default Table Parameter

Default

Page Number

Set Default Parameter

All Defaults

5-7

Host Type

See page 5-8

5-8

Triggered Omnidirectional

5-16

0.5 seconds

5-18

Beeper Volume

High

5-19

Beeper Frequency

High Frequency

5-21

Time-out Between Decodes, Same Symbol

Triggered: 200 msec; ConstantOn: 2 sec

5-23

Time-out Between Decodes, Different Symbols

600 msec

5-24

Laser On Time

2.0 seconds

5-25

Rest Mode Timeout

30 minutes

5-26

Enable

5-28

2

5-29

Trigger Mode

Time to Return to Continuous Omnidirectional

Beep After Good Decode Linear Code Type Security Levels

5-2

Page 36

Programming the LS 6000

Table 5-1. Default Table (cont’d) Parameter

Default

Page Number

UPC-A

Enable

5-32

UPC-E

Enable

5-32

EAN-8

Enable

5-34

EAN-13

Enable

5-34

Bookland EAN

Disable

5-36

Decode UPC/EAN Supplementals

Ignore

5-37

Decode UPC/EAN Supplemental Redundancy

20

5-39

Transmit UPC-A Check Digit

Enable

5-40

Transmit UPC-E Check Digit

Enable

5-41

Random Weight Check Digit

Disable

5-42

UPC-A Preamble

System Character

5-43

UPC-E Preamble

System Character

5-45

Convert UPC-E to A

Disable

5-47

EAN-8 Zero Extend

Disable

5-48

UPC/EAN Predecode Block

Reject

5-49

UPC/EAN

5-3

Page 37

LS 6000 Series Product Reference Guide

Table 5-1. Default Table (cont’d) Parameter

Default

Page Number

UPC/EAN Security Levels

0

5-51

Linear UPC/EAN Decode

Disable

5-54

Linear Supplemental Decode

Disable

5-55

UPC/EAN Decode Performance

Enable, Level 3

5-56

Disable

5-58

Enable

5-59

Enable, Level 3

5-60

Enable

5-62

Code 39

Enable

5-63

Set Length(s) for Code 39

1 to 55

5-64

Code 39 Check Digit Verification

Disable

5-67

Transmit Code 39 Check Digit

Disable

5-68

Code 39 Decode Performance

Enable, Level 3

5-69

Code 39 Full ASCII Conversion

Disable

5-71

UPC/EAN Coupon Code Code 128 Code 128 Code 128 Decode Performance UCC/EAN-128 Code 39

5-4

Page 38

Programming the LS 6000

Table 5-1. Default Table (cont’d) Parameter

Default

Page Number

Disable

5-73

14

5-74

I 2 of 5 Check Digit Verification

Disable

5-77

Transmit I 2 of 5 Check Digit

Disable

5-79

Convert I 2 of 5 to EAN 13

Disable

5-80

Codabar

Disable

5-81

Set Lengths for Codabar

5-55

5-82

CLSI Editing

Disable

5-85

NOTIS Editing

Disable

5-86

None

5-87

0

5-89

7013 (<CR/LF> for serial)

5-90

Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5

Codabar

Data Options Transmit Code ID Character Pause Duration Prefix/Suffix Values

5-5

Page 39

LS 6000 Series Product Reference Guide

Table 5-1. Default Table (cont’d) Parameter

Default

Page Number

Scan Data Transmission Format

Data as is

5-91

Standard

5-10

Baud Rate

9600

5-95

Parity

Even

5-99

Check Receive Errors

Check

5-102

Hardware Handshaking

None

5-103

Software Handshaking

None

5-107

Host Serial Response Time-out

2 Sec.

5-111

RTS Line State

Low

5-112

Stop Bit Select

1

5-113

ASCII Format

8-Bit

5-114

Beep on <BEL>

Disable

5-115

0

5-116

RS-232C RS-232 Host Type

Intercharacter Delay Numeric Bar Codes

5-6

5-117

Page 40

Programming the LS 6000

Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 5-1 beginning on page 5-2.

SET ALL DEFAULTS

5-7