The text of a manual · part 16 of 18
LS 6000 Series Product Reference Guide, pages 151 to 160
Pages 151 to 160 of 175
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-6005 and Symbol LS-6004
Page 151
ee |_! LS 6000 Series Product Reference Guide
Numeric Bar Codes (Cont’d)
2
3
5-118
Page 152
Programming the LS 6000
Numeric Bar Codes (Cont’d)
4
5
5-119
Page 153
ee |_! LS 6000 Series Product Reference Guide
Numeric Bar Codes (Cont’d)
6
7
5-120
Page 154
Programming the LS 6000
Numeric Bar Codes (Cont’d)
8
9
5-121
Page 155
LS 6000 Series Product Reference Guide
Cancel If you make an error or wish to change your selection, scan the bar code below.
CANCEL
5-122
Page 156
Appendix A Programming Reference UCC/EAN-128 UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields. When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character. When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. For example, ]c1 indicates a UCC/ EAN-128 symbol with a leading FNC1 character. Standard Code 128 bar codes which do not have a leading FNC 1 may still be used but are not encoded according to the EAN128 convention. Standard Code 128 and UCC/EAN-128 may be mixed in an application. The LS 6000 autodiscriminates A-1
Page 157
LS 6000 Series Product Reference Guide between these symbols, and can enable or disable one or both code types via bar code menus. Table A-1 indicates the behavior of the LS 6000 in each of the four possible parameter settings.
Table A-1. Reading Standard Code128 & UCC/EAN 128 Standard Code 128
UCC/ EAN-128
Disable
Disable
No Code 128 symbols can be read.
Disable
Enable
Read only symbols with leading FNC 1. Examples: FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1 ABCDFNC1E are read as ABCD29E ABCDFNC1E cannot be read ABCDE cannot be read
Enable
Disable
Read only symbols without leading FNC 1. Examples: FNC1 ABCDFNC1E cannot be read FNC1 BCDFNC1E cannot be read A FNC1FNC1 ABCDFNC1E cannot be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE
A-2
Effect and Example
Page 158
Programming Reference
Table A-1. Reading Standard Code128 & UCC/EAN 128 Standard Code 128
UCC/ EAN-128
Enable
Enable
Effect and Example
Read both types of symbols. Examples: FNC1 ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1 ABCDFNC1E are read as ABCD29E ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE
A-3
Page 159
LS 6000 Series Product Reference Guide
AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = c = m =
Flag Character (ASCII 93) Code Character (see Table A-2) Modifier Character (see Table A-3)
Table A-2. Code Characters
A-4
Code Character
Code Type
A
Code 39
C
Code 128
E
UPC/EAN
F
Codabar
I
Interleaved 2 of 5
X
Bookland EAN
Page 160
Programming Reference
Modifier Characters The modifier character is the sum of the applicable option values based on Table A-3. Table A-3. Modifier Characters Code Type Code 39
Option Value
Option
0
No check character or Full ASCII processing.
1
Reader has checked one check character.
3
Reader has checked and stripped check character.
4
Reader has performed Full ASCII character conversion.
5
Reader has performed Full ASCII character conversion and checked one check character.
7
Reader has performed Full ASCII character conversion and checked and stripped check character.
Example:A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4).
A-5